Overview of special ECOFLOOR heating<br />
cables and recommended usage<br />
Type<br />
Wattage [W/m]<br />
Overview of ECOFLOOR heating mats and recommended usage<br />
PSV cable<br />
PSV heating circuits, LPSV heating mats<br />
ADPSV cable<br />
ADPSV heating circuits<br />
MAPSV cable<br />
MAPSV heating circuits, MST heating mats<br />
MADPSP cable<br />
MADPSP heating circuits, MDT heating mats<br />
PDSP cable<br />
PDSP heating circuits<br />
PDS1P cable<br />
for curing concrete<br />
Number of heating cores<br />
Protective screen<br />
Protection against UV radiation<br />
Thermal endurance of the jacket<br />
Supplied as circuit<br />
Supplied as mat<br />
Direct-heating<br />
Floor heating<br />
Semi-storage<br />
Storage<br />
Surfaces<br />
Anti-freeze<br />
protection of<br />
ELSR-M<br />
10<br />
15<br />
2<br />
●<br />
●<br />
●<br />
●<br />
65 °C<br />
●<br />
●<br />
●<br />
●<br />
ELSR-N<br />
20<br />
30<br />
2<br />
●<br />
●<br />
●<br />
●<br />
80 °C<br />
●<br />
●<br />
●<br />
●<br />
●<br />
●<br />
PCC 30 1 ● −40…60 °C ●<br />
PC<br />
25<br />
50<br />
2 −50…60 °C<br />
●<br />
●<br />
PC-S<br />
20<br />
25<br />
2<br />
●<br />
●<br />
−50…60 °C<br />
●<br />
●<br />
Type<br />
Wattage [W/m]<br />
Number of heating cores<br />
Protective screen<br />
Protection against UV radiation<br />
Thermal endurance of the jacket<br />
Direct-heating<br />
Floor heating<br />
CM 150 2 ● 90 °C ● ADSA<br />
80 ●<br />
● ●<br />
LDTS 100 2 ● 70 °C ● ●<br />
ADSV-T<br />
160 ● ● ●<br />
LD 160 1 ● 70 °C ● ● ASL1P<br />
LSDTS<br />
100<br />
160<br />
2<br />
●<br />
●<br />
70 °C<br />
●<br />
●<br />
ADSV-T<br />
LPSV 100 1 ● 80 °C ● PSV<br />
MST 300 1 ● ● 80 °C ● MAPSV<br />
MDT 300 2 ● ● 90 °C ● ● MADPSP<br />
Semi-storage<br />
Storage<br />
Heating of outdoor areas<br />
Roofs<br />
Type of heating cable<br />
Pipes<br />
13<br />
Cable composition markings<br />
1 2 3 4 5 6<br />
M A D P S P<br />
1 Resistance (heating) wire<br />
M multi-resistance – stranded resistance wire<br />
(to be used for higher outputs);<br />
no letter is used for a non-stranded (simple) resistance wire<br />
2 Core insulation<br />
A FEP (fl uoropolymer)<br />
P XLPE (cross-linked polyethylene)<br />
3 Number of heating cores<br />
D double-core cable;<br />
no letter is used for a single-core cable<br />
4 Plastic insulation (for outdoor applications,<br />
higher mechanical ruggedness of cable)<br />
P XLPE (cross-linked polyethylene);<br />
no letter is used for a cable without<br />
the second plastic insulation<br />
5 Protection screen (for wet areas)<br />
S full screen protection (tinned copper<br />
wires and aluminium tape)<br />
SL linear screen protection<br />
no letter is used for a cable without screen protection<br />
6 Jacket<br />
P XLPE (cross-linked polyethylene)<br />
1P PP-LDPE (mixed polypropylene & low density PE)<br />
V PVC (polyvinyl chloride)<br />
ELSR-M cable<br />
self-regulating cable for anti-freeze protection and<br />
technological heating (10 and 15 W/m)<br />
ELSR-N cable<br />
self-regulating cable for anti-freeze protection and<br />
technological heating (20 and 30 W/m EExII)<br />
PCC cable<br />
heating circuits for anti-freeze protection –<br />
heating of the insulating door seals of freezers<br />
PC cable<br />
heating cable with a constant linear wattage for<br />
anti-freeze protection and process heating<br />
PC-S cable<br />
armoured heating cable (metal braiding)<br />
with a constant linear wattage for anti-freeze<br />
protection and process heating<br />
Linear input of cable [W/m]<br />
2 0 2 4 0<br />
Total input of circuit [W]