<strong>Technical</strong> <strong>Data</strong> / <strong>SkyPo</strong> <strong>Seat</strong> <strong>Power</strong> <strong>Module</strong><br />

SPM<br />

J7 J21<br />

J6<br />

J5<br />

J4<br />

J3<br />

<strong>KID</strong>-SYSTEME<br />

J8


<strong>Technical</strong> <strong>Data</strong> / <strong>SkyPo</strong> <strong>Seat</strong> <strong>Power</strong> <strong>Module</strong><br />

SPM – ONE SERVES UP TO 4 SEATS<br />

The new enhanced <strong>Seat</strong> <strong>Power</strong> <strong>Module</strong> provides AC and DC power to the IFE equipment as well as<br />

to the passenger power equipment.<br />

TECHNICAL DATA<br />

Dimensions: 163 x 200 x 53.8 mm<br />

Weight: max. 1.6 kg<br />

<strong>Power</strong> input: 115V AC / 360-800Hz one phase<br />

(3 phases daisy chain)<br />

<strong>Power</strong> consumption: max. 470W @ 250W PED load and<br />

150W 28V DC. Passive Cooling<br />

PED <strong>Power</strong> output: 110V AC / 60Hz max. 250W total<br />

4 power outputs / max. 150W each<br />

Safety functions: over current and over/under voltage<br />

protection, short circuit and thermal protection,<br />

GFI for passenger safety (according to<br />

UL 943 Class A) continuously tested<br />

IFE power out: 28V DC max. 150W Short circuit protection<br />

BITE: power up and continuous build in test<br />

Qualifications: according to <strong>Airbus</strong> (incl. A380) and<br />

Boeing requirements<br />

4 x Passenger<br />

Electronic Device<br />

<strong>Power</strong><br />

4 x IFE (28V DC)<br />

in RS-485<br />

4 x <strong>Power</strong> in Use Indication Lights<br />

RS-485 Daisy Chain<br />

INTERFACES<br />

RS-232<br />

(maintenance)<br />

<strong>KID</strong>-SYSTEME<br />

• <strong>Data</strong> line (3 level) input for PED output power control<br />

• Serial interfaces (RS-485) for data exchange with other in-seat<br />

components (according to ARINC 628) for:<br />

– BITE (e.g. centralized BITE via IFE)<br />

– <strong>Power</strong> Management<br />

– SW-Download<br />

– PPUI dimming<br />

– IFE power output control<br />

– Status data (e.g. centralized “<strong>Power</strong> In Use Indication” via IFE)<br />

• Discrete outputs for power in use indication light (PPUI):<br />

– One or two general common PPUI<br />

– One per ACOU<br />

– Dimmable via RS-485<br />

– Discrete input to control PED, IFE and Aux. <strong>Power</strong><br />

– Service Interface (RS-232)<br />

INTERCHANGEABILITY<br />

PED <strong>Power</strong> compatible with SKYpower<br />

AUXILIARY POWER OUTPUT<br />

3 phases 115V AC switchable<br />

115V AC<br />

(AUX eg. SCB)<br />

<strong>Power</strong> In<br />

<strong>Power</strong> Out<br />

<strong>KID</strong>-SYSTEME GMBH • LÜNEBURGER SCHANZE 30 • 21614 BUXTEHUDE • GERMANY • PHONE +49 (0) 40 743-71633 • FAX +49 (0) 40 743-83829 • WWW.<strong>KID</strong>-SYSTEME.COM<br />

© AIRBUS <strong>KID</strong>-SYSTEME 2006 • Our products are constantly being improved, technical modifications are therefore possible. • ALL RIGHTS RESERVED

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!