31.01.2013 Views

Download UP50 product catalog in PDF format for - Panasonic ...

Download UP50 product catalog in PDF format for - Panasonic ...

Download UP50 product catalog in PDF format for - Panasonic ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Energy-Efficient and<br />

Stable UV Irradiation<br />

Per<strong>for</strong>mance<br />

2011.02 panasonic-electric-works.net/sunx<br />

Lamp Spot Type<br />

UV CURING SYSTEM<br />

Aicure <strong>UP50</strong><br />

<strong>Panasonic</strong> Electric Works SUNX


Aicure <strong>UP50</strong><br />

2<br />

Featur<strong>in</strong>g an energy-efficient<br />

mode, which cuts the power<br />

consumption by a maximum<br />

of 15% while the irradiation<br />

is off, and a high-accuracy<br />

auto-tun<strong>in</strong>g function<br />

High-efficiency UV irradiation Stable UV irradiation per<strong>for</strong>mance<br />

Eco mode reduces power consumption.<br />

The Eco mode cuts the<br />

standby power consumption by<br />

a maximum of 15% while the<br />

irradiation is off (the shutter is<br />

closed), contribut<strong>in</strong>g to the<br />

runn<strong>in</strong>g costs (electricity<br />

charge). Compatible with a<br />

wide range of power supply<br />

voltages from 100 to 240 V AC<br />

<strong>for</strong> worldwide use.<br />

Typical<br />

characteristics<br />

The use of the filter is recommended especially <strong>for</strong> heat-sensitive workpieces.<br />

You can reduce temperature rises <strong>in</strong> the irradiation unit by attach<strong>in</strong>g a heat<br />

reflect<strong>in</strong>g filter depend<strong>in</strong>g on the type of workpiece.<br />

Typical<br />

characteristics<br />

Relative spectral radiant <strong>in</strong>tensity<br />

Temperature (°C °F)<br />

100<br />

0<br />

200<br />

45<br />

113<br />

40<br />

104<br />

35<br />

95<br />

30<br />

86<br />

25<br />

77 24.0<br />

20<br />

68 0<br />

Power consumption when the UV auto control is on<br />

Power consumption (VA)<br />

AN<strong>UP50</strong>01F heat ray cut filter prevents<br />

temperature rises <strong>in</strong> the irradiation unit.<br />

280<br />

When the irradiation is on<br />

(the shutter is opened)<br />

Cut by<br />

5%<br />

Cut by<br />

10%<br />

Cut by<br />

15%<br />

max.<br />

238 When the irradiation is off<br />

(the shutter is closed)<br />

0 1000 2000 3000<br />

Lamp light<strong>in</strong>g time (H)<br />

Surface tack<strong>in</strong>ess can be quickly elim<strong>in</strong>ated.<br />

The development and adoption of our unique special mirror that allows <strong>for</strong> the<br />

effective irradiation with short wavelengths enables the quick elim<strong>in</strong>ation of<br />

surface stick<strong>in</strong>ess caused dur<strong>in</strong>g cur<strong>in</strong>g. The irradiation time can also be<br />

reduced, decreas<strong>in</strong>g the temperature rise of workpieces.<br />

300 400 500<br />

Wavelengths (nm)<br />

Without filter<br />

AN<strong>UP50</strong>01F<br />

• Workpiece: Al (30 × t0.5 mm 1.181 × t0.020 <strong>in</strong>)<br />

• Distance: 30 mm 1.181 <strong>in</strong><br />

• Intensity: 400 W/cm 2<br />

• Fiber: ANUP3052 + AN<strong>UP50</strong>001BS<br />

5 10 15 20 25 30<br />

Irradiation time (sec)<br />

40.9 (+16.2)<br />

105.62 (+61.16)<br />

36.2 (+12.2)<br />

97.16 (+53.96)<br />

UV auto control function automatically<br />

compensates <strong>for</strong> the UV <strong>in</strong>tensity<br />

This function <strong>in</strong>creases the electrical power applied to the lamp accord<strong>in</strong>g to<br />

the total irradiation time of the lamp to compensate <strong>for</strong> the UV <strong>in</strong>tensity<br />

decrease, ma<strong>in</strong>ta<strong>in</strong><strong>in</strong>g stable UV irradiation until the end of the lamp life.<br />

Typical<br />

characteristics<br />

Relative <strong>in</strong>tensity<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

0<br />

H-ON<br />

V-OFF<br />

V-ON<br />

H-OFF<br />

V-ON: Vertically <strong>in</strong>stalled and auto control is on.<br />

V-OFF: Vertically <strong>in</strong>stalled and auto control is off.<br />

H-ON: Horizontally <strong>in</strong>stalled and auto control is on.<br />

H-OFF: Horizontally <strong>in</strong>stalled and auto control is off.<br />

<strong>UP50</strong><br />

1000 2000 3000<br />

Lamp light<strong>in</strong>g time (H)<br />

Significantly higher reliability <strong>for</strong> bond<strong>in</strong>g and fix<strong>in</strong>g<br />

Slim UV sensor (optional)<br />

The UV sensor <strong>for</strong> measur<strong>in</strong>g irradiation <strong>in</strong>tensity enables<br />

<strong>Panasonic</strong>'s<br />

orig<strong>in</strong>al<br />

auto-turn<strong>in</strong>g <strong>in</strong> high-accuracy.<br />

The UV <strong>in</strong>tensity can be<br />

relative measured* at the<br />

actual position by us<strong>in</strong>g<br />

the slim UV sensor. It can<br />

also automatically adjust<br />

the UV <strong>in</strong>tensity to the<br />

preset level. S<strong>in</strong>ce the<br />

sensor only has 5 mm<br />

(0.2 <strong>in</strong>) thickness, which<br />

is similar to the<br />

workpiece, the <strong>in</strong>tensity<br />

5mm<br />

measurement is possible<br />

without remov<strong>in</strong>g the<br />

system from the<br />

<strong>product</strong>ion l<strong>in</strong>e, facilitat<strong>in</strong>g<br />

high-accuracy sett<strong>in</strong>g and <strong>in</strong>-l<strong>in</strong>e condition optimization. The UV <strong>in</strong>tensity can<br />

be checked and adjusted at real time, enhanc<strong>in</strong>g the bond<strong>in</strong>g and<br />

fix<strong>in</strong>g reliability.<br />

* UV <strong>in</strong>tensity can be measured as a relative value.<br />

NEW


Stable UV irradiation per<strong>for</strong>mance<br />

Programmable irradiation function<br />

This function prevents cur<strong>in</strong>g distortion and enables<br />

high-quality precision bond<strong>in</strong>g.<br />

Program mode<br />

Specifications<br />

Aicure Product No.<br />

Power supply<br />

Lamp<br />

UV <strong>in</strong>tensity<br />

STEP=1<br />

Lamp Product No.<br />

Pattern 0<br />

STEP=2<br />

STEP=3<br />

Interval (closed)<br />

STEP=5<br />

Interval (closed)<br />

AN<strong>UP50</strong><br />

STEP=7<br />

90 to 264 V AC 50/60 Hz 280 V A<br />

ANUPS204<br />

Time<br />

…<br />

200 W mercury xenon lamp, preset quickly-attachable type<br />

* Average life of 3,000 hours: Ratio to the <strong>in</strong>itial UV <strong>in</strong>tensity --<br />

80% or higher <strong>in</strong> a vertical position, 70% or higher <strong>in</strong> a horizontal<br />

position (when the auto control function is off)<br />

* Guaranteed life: 2,000 hours<br />

Pattern 9<br />

Time<br />

The irradiation can be programmed to controls the irradiation power and time<br />

depend<strong>in</strong>g on the res<strong>in</strong> and cur<strong>in</strong>g appication, support<strong>in</strong>g high-quality and<br />

high-precision bond<strong>in</strong>g with m<strong>in</strong>imum cure shr<strong>in</strong>kage. In addition to the simple<br />

irradiation mode which irradiation is cont<strong>in</strong>uously per<strong>for</strong>med at a constant<br />

<strong>in</strong>tensity, up to 10 steps 10 patterns can be set. This <strong>in</strong>cludes the step-up<br />

mode which the <strong>in</strong>tensity is changed over time and the <strong>in</strong>terval mode which<br />

irradiation is per<strong>for</strong>med at specified <strong>in</strong>tervals.<br />

Digital sett<strong>in</strong>g allows <strong>for</strong> consistency of set<br />

values from operator to operator.<br />

The irradiation power can be f<strong>in</strong>ely set <strong>in</strong> the range of 0 to 100% <strong>in</strong><br />

<strong>in</strong>crements of 0.5%. The actual UV irradiation <strong>in</strong>tensity is approximately<br />

proportional to the displayed value, mak<strong>in</strong>g the sett<strong>in</strong>g work easier and more<br />

accurate.<br />

Interchangeability with ANUP5204<br />

The wavelength distribution (typical characteristics) of <strong>UP50</strong> is identical to<br />

ANUP5204, our exist<strong>in</strong>g model. The replacement lamp, the ANUPS204, is<br />

also the same as that <strong>for</strong> the ANUP5204.<br />

STEP=1<br />

STEP=10<br />

Easy to <strong>in</strong>stall<br />

Can be placed either<br />

vertically or horizontally .<br />

The unit can be placed <strong>in</strong> either a vertical<br />

position that makes the footpr<strong>in</strong>t smaller<br />

or a horizontal position that allows<br />

stack<strong>in</strong>g other units.<br />

Long life, quickly-attachable lamp<br />

The average lamp life is 3,000 hours<br />

(guaranteed life: 2,000 hours*). The lamp<br />

can be easily replaced with a s<strong>in</strong>gle<br />

operation and does not require an optical<br />

axis adjustment.<br />

* Ratio to the <strong>in</strong>itial UV <strong>in</strong>tensity -- 80% or higher <strong>in</strong><br />

vertical placement, 70% or higher <strong>in</strong> horizontal placement<br />

Two lens unit models <strong>for</strong> short and long range<br />

converg<strong>in</strong>g<br />

The two lens unit models, one <strong>for</strong> short range and the other <strong>for</strong> long range<br />

converg<strong>in</strong>g, cover a variety of applications and work pieces.<br />

Slim AS and<br />

BS lens units<br />

UV irradiation<br />

Shutter<br />

Sett<strong>in</strong>g<br />

External signal<br />

Dimensions<br />

Input<br />

Output<br />

Light guide fiber<br />

Please refer to page 5 <strong>for</strong> the UV <strong>in</strong>tensity distribution data.<br />

Aicure <strong>UP50</strong><br />

AS lens<br />

Short range<br />

converg<strong>in</strong>g lens<br />

BS lens<br />

Long range<br />

converg<strong>in</strong>g lens<br />

UV <strong>in</strong>tensity adjustment by digital sett<strong>in</strong>g (0 to 100%, <strong>in</strong> <strong>in</strong>crements of 0.5%)<br />

UV auto control<br />

Programmable irradiation (10 steps <strong>in</strong> each of 10 patterns)<br />

External signal control: Turn<strong>in</strong>g the lamp on/off, manual open<strong>in</strong>g/clos<strong>in</strong>g<br />

of the shutter, start<strong>in</strong>g programmed pattern irradiation, start<strong>in</strong>g<br />

timer-controlled irradiation, and execut<strong>in</strong>g calibration<br />

Electronically-controlled shutter us<strong>in</strong>g manual or timer-controlled operation<br />

Digital sett<strong>in</strong>g us<strong>in</strong>g membrane switches<br />

Open<strong>in</strong>g/clos<strong>in</strong>g the shutter (timer/manual), light<strong>in</strong>g the lamp<br />

Light<strong>in</strong>g the lamp, stabiliz<strong>in</strong>g the lamp light, open<strong>in</strong>g the shutter,<br />

outputt<strong>in</strong>g error signals, and <strong>in</strong>dicat<strong>in</strong>g the lamp life<br />

165 × 201 × 325 mm 6.496 × 7.913 × 12.795 <strong>in</strong> (Exclud<strong>in</strong>g protrud<strong>in</strong>g sections)<br />

Weight<br />

8 kg approx.<br />

Please refer to page 4 <strong>for</strong> the light guide fiber units and other optional parts.<br />

(Vertical placement)<br />

3


Light guide fiber units<br />

Number of<br />

branches<br />

Shape<br />

Bundle diameter:<br />

3.5 mm 0.138 <strong>in</strong><br />

(light outlet end)<br />

Bundle diameter:<br />

5 mm 0.197 <strong>in</strong><br />

(light outlet end)<br />

Bundle diameter:<br />

8 mm 0.315 <strong>in</strong><br />

(light outlet end)<br />

Others<br />

Product name<br />

Lens*<br />

Heat ray cut filter<br />

Goggles<br />

Lamp<br />

Lamp lead wire<br />

UV sensor<br />

1 2 3 4<br />

AN<strong>UP50</strong>31 AN<strong>UP50</strong>32 AN<strong>UP50</strong>33 AN<strong>UP50</strong>34<br />

AN<strong>UP50</strong>51 AN<strong>UP50</strong>52 AN<strong>UP50</strong>53 AN<strong>UP50</strong>54<br />

AN<strong>UP50</strong>81<br />

UV sensor extension cable<br />

Specifications<br />

Beij<strong>in</strong>g<br />

Chengdu Shanghai<br />

Daliand<br />

Korea<br />

Guangzhou<br />

Shenzhen<br />

Taiwan<br />

Hong Kong<br />

Bangkok<br />

Malaysia<br />

S<strong>in</strong>gapore<br />

Jakarta<br />

Shenyang<br />

Japan<br />

Product No.<br />

AN<strong>UP50</strong>01AS<br />

AN<strong>UP50</strong>01BS<br />

AN<strong>UP50</strong>01F<br />

AN<strong>UP50</strong>01SG<br />

ANUPS204<br />

ANUPS50H2<br />

ANUJ3800<br />

ANUJ38110<br />

ANUJ38102<br />

We have local sales companies to support the expansion of customers’ global<br />

operations. Please visit our website to see our worldwide sales network.<br />

Ø7.5<br />

Ø0.295<br />

Ø11.5<br />

Ø0.453<br />

Ø5.5<br />

Ø0.217<br />

Ø5.0<br />

Ø0.197<br />

A i c u r e U P 5 0<br />

Options Intensity Profiles (Typical examples)<br />

Short range converg<strong>in</strong>g lens<br />

Long range converg<strong>in</strong>g lens<br />

Reflection type<br />

UV protective goggles<br />

For AN<strong>UP50</strong><br />

For AN<strong>UP50</strong><br />

Slim type (Thickness: 5 mm 0.197 <strong>in</strong>)<br />

Length: 10 m 32.808 ft<br />

Length: 2 m 6.562 ft<br />

* Please consult us separately <strong>for</strong> the lens <strong>for</strong> the Ø8 mm Ø0.315 <strong>in</strong> fiber unit.<br />

Available <strong>for</strong> worldwide use<br />

http://panasonic-denko.co.jp/ac/e/salesnetwork/<strong>in</strong>dex.jsp<br />

Bundle diameter: 8 mm 0.315 <strong>in</strong>, Straight<br />

Irradiation distance (mm <strong>in</strong>)<br />

UV <strong>in</strong>tensity (mW/cm2)<br />

15<br />

0.591<br />

20<br />

0.787<br />

30<br />

1.181<br />

40<br />

1.575<br />

3000<br />

2000<br />

1000<br />

0<br />

AN<strong>UP50</strong>81 (Without lens)<br />

Central <strong>in</strong>tensity<br />

2210 mW/cm2<br />

1900 mW/cm2<br />

1050 mW/cm2<br />

580 mW/cm2<br />

: 70% irradiation diameter <strong>in</strong>tensity at central <strong>in</strong>tensity.<br />

Irradiation distance<br />

-15<br />

-0.591<br />

-10<br />

-0.394<br />

-5<br />

-0.197<br />

0<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

Irradiation area (mm <strong>in</strong>)<br />

Ø5 × 1 branch<br />

Ø5 × 2 branches<br />

Ø5 × 3 branches<br />

Ø5 × 4 branches<br />

Ø3.5 × 1 branch<br />

Ø3.5 × 2 branches<br />

Ø3.5 × 3 branches<br />

Ø3.5 × 4 branches<br />

15 mm 0.591 <strong>in</strong><br />

20 mm 0.787 <strong>in</strong><br />

30 mm 1.181 <strong>in</strong><br />

40 mm 1.575 <strong>in</strong><br />

15<br />

0.591<br />

[Rough guide of the relationship between the number of fiber<br />

unit branches and the UV <strong>in</strong>tensity ratio]<br />

(Irradiation distance: 15 mm 0.591 <strong>in</strong>, Ø1 mm Ø0.039 <strong>in</strong> sensor)<br />

UV <strong>in</strong>tensity ratio<br />

Fiber unit<br />

Without lens<br />

100%<br />

75%<br />

55%<br />

50%<br />

100%<br />

80%<br />

62%<br />

57%<br />

With lens<br />

100%<br />

65%<br />

53%<br />

45%<br />

100%<br />

75%<br />

60%<br />

50%<br />

4


Irradiation distance (mm <strong>in</strong>)<br />

UV <strong>in</strong>tensity (mW/cm2)<br />

Irradiation distance (mm <strong>in</strong>)<br />

UV <strong>in</strong>tensity (mW/cm2)<br />

Bundle diameter: 5 mm 0.197 <strong>in</strong>, Straight<br />

5<br />

0.197<br />

10<br />

0.394<br />

15<br />

0.591<br />

20<br />

0.787<br />

25<br />

0.984<br />

30<br />

1.181<br />

40<br />

1.575<br />

50<br />

1.969<br />

80<br />

3.150<br />

100<br />

3.937<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1000<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

15<br />

0.591<br />

20<br />

0.787<br />

25<br />

0.984<br />

30<br />

1.181<br />

40<br />

1.575<br />

50<br />

1.969<br />

80<br />

3.150<br />

100<br />

3.937<br />

5000<br />

4000<br />

3000<br />

2000<br />

1000<br />

0<br />

Ø33.0<br />

Ø1.299<br />

Ø42.0<br />

Ø1.654<br />

Ø36.5<br />

Ø1.437<br />

Ø44.0<br />

Ø1.732<br />

A i c u r e U P 5 0<br />

AN<strong>UP50</strong>51 (Without lens) AN<strong>UP50</strong>51AS (With AS lens) AN<strong>UP50</strong>51BS (With BS lens)<br />

Ø5.0<br />

Ø0.197<br />

Central <strong>in</strong>tensity<br />

1990 mW/cm2<br />

Ø7.5<br />

Ø0.295<br />

Central <strong>in</strong>tensity<br />

890 mW/cm2<br />

Central <strong>in</strong>tensity<br />

Ø2.0<br />

Ø0.079<br />

6730 mW/cm2<br />

Ø6.5<br />

Ø0.256<br />

980 mW/cm2<br />

Ø3.5<br />

Ø0.138<br />

2300 mW/cm2<br />

Ø4.0<br />

Ø0.157<br />

3560 mW/cm2<br />

Ø5.0<br />

Ø0.197<br />

1700 mW/cm2<br />

Ø4.0<br />

Ø0.157<br />

1340 mW/cm2<br />

Ø6.5<br />

Ø0.256<br />

1750 mW/cm2<br />

Ø3.0<br />

Ø0.118<br />

3250 mW/cm2<br />

Ø6.0<br />

Ø0.236<br />

800 mW/cm2<br />

Ø6.5<br />

Ø0.256<br />

1070 mW/cm2<br />

Ø3.5<br />

Ø0.138<br />

2720 mW/cm2<br />

Ø11.0<br />

Ø0.433<br />

510 mW/cm2<br />

Ø9.0<br />

Ø0.354<br />

650 mW/cm2<br />

Ø6.0<br />

Ø0.236<br />

1840 mW/cm2<br />

Ø15.5<br />

Ø0.610<br />

250 mW/cm2<br />

Ø11.0<br />

Ø0.433<br />

340 mW/cm2<br />

Ø8.0<br />

Ø0.315<br />

890 mW/cm2<br />

Ø20.0<br />

Ø0.787<br />

140 mW/cm2<br />

Ø14.5<br />

Ø0.571<br />

200 mW/cm2<br />

Ø9.5<br />

Ø0.374<br />

510 mW/cm2<br />

50 mW/cm2<br />

Ø22.0<br />

Ø0.866<br />

70 mW/cm2<br />

Ø17.5<br />

Ø0.689<br />

160 mW/cm2<br />

30 mW/cm2<br />

Ø27.0<br />

Ø1.063<br />

40 mW/cm2<br />

Ø21.0<br />

Ø0.827<br />

100 mW/cm2<br />

: 70% irradiation diameter <strong>in</strong>tensity at central <strong>in</strong>tensity.<br />

Irradiation distance Irradiation distance Irradiation distance<br />

80 mm 3.150 <strong>in</strong><br />

100 mm 3.937 <strong>in</strong><br />

-15<br />

-0.591<br />

-10<br />

-0.394<br />

-5<br />

-0.197<br />

0<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

Irradiation area (mm <strong>in</strong>)<br />

15 mm 0.591 <strong>in</strong><br />

20 mm 0.787 <strong>in</strong><br />

25 mm 0.984 <strong>in</strong><br />

30 mm 1.181 <strong>in</strong><br />

40 mm 1.575 <strong>in</strong><br />

50 mm 1.969 <strong>in</strong><br />

80 mm 3.150 <strong>in</strong><br />

100 mm 3.937 <strong>in</strong><br />

Bundle diameter: 3.5 mm 0.138 <strong>in</strong>, Straight<br />

10 mm 0.394 <strong>in</strong><br />

15 mm 0.591 <strong>in</strong><br />

5 mm 0.197 <strong>in</strong><br />

20 mm 0.787 <strong>in</strong><br />

25 mm 0.984 <strong>in</strong><br />

30 mm 1.181 <strong>in</strong><br />

40 mm 1.575 <strong>in</strong><br />

25 mm 0.984 <strong>in</strong><br />

80 mm 3.150 <strong>in</strong><br />

100 mm 3.937 <strong>in</strong><br />

AN<strong>UP50</strong>31 (Without lens) AN<strong>UP50</strong>31AS (With AS lens) AN<strong>UP50</strong>31BS (With BS lens)<br />

Ø4.5<br />

Ø0.177<br />

Central <strong>in</strong>tensity<br />

3990 mW/cm2<br />

Ø5.5<br />

Ø0.217<br />

Central <strong>in</strong>tensity<br />

570 mW/cm2<br />

Ø8.5<br />

Ø0.335<br />

Central <strong>in</strong>tensity<br />

220 mW/cm2<br />

Ø2.5<br />

Ø0.098<br />

2730 mW/cm2<br />

Ø3.0<br />

Ø0.118<br />

3040 mW/cm2<br />

Ø7.0<br />

Ø0.276<br />

270 mW/cm2<br />

Ø5.0<br />

Ø0.197<br />

1220 mW/cm2<br />

Ø2.5<br />

Ø0.098<br />

3900 mW/cm2<br />

Ø7.0<br />

Ø0.276<br />

510 mW/cm2<br />

Ø8.5<br />

Ø0.335<br />

480 mW/cm2<br />

Ø4.5<br />

Ø0.177<br />

1820 mW/cm2<br />

Ø4.0<br />

Ø0.157<br />

1520 mW/cm2<br />

Ø10.5<br />

Ø0.413<br />

230 mW/cm2<br />

Ø5.5<br />

Ø0.217<br />

1050 mW/cm2<br />

Ø4.0<br />

Ø0.157<br />

2470 mW/cm2<br />

Ø13.0<br />

Ø0.512<br />

140 mW/cm2<br />

Ø6.0<br />

Ø0.236<br />

690 mW/cm2<br />

Ø3.5<br />

Ø0.138<br />

2020 mW/cm2<br />

Ø18.0<br />

Ø0.709<br />

60 mW/cm2<br />

Ø7.5<br />

Ø0.295<br />

360 mW/cm2<br />

Ø6.5<br />

Ø0.256<br />

900 mW/cm2<br />

Ø22.5<br />

Ø0.886<br />

30 mW/cm2<br />

Ø9.0<br />

Ø0.354<br />

220 mW/cm2<br />

Ø7.5<br />

Ø0.295<br />

520 mW/cm2<br />

10 mW/cm2<br />

Ø13.0<br />

Ø0.512<br />

80 mW/cm2<br />

Ø11.5<br />

Ø0.453<br />

170 mW/cm2<br />

10 mW/cm2<br />

Ø15.0<br />

Ø0.591<br />

50 mW/cm2<br />

Ø14.0<br />

Ø0.551<br />

100 mW/cm2<br />

20 mm 0.787 <strong>in</strong><br />

25 mm 0.984 <strong>in</strong><br />

15 mm 0.591 <strong>in</strong><br />

10 mm 0.394 <strong>in</strong><br />

30 mm 1.181 <strong>in</strong><br />

5 mm 0.197 <strong>in</strong><br />

40 mm 1.575 <strong>in</strong><br />

50 mm 1.969 <strong>in</strong><br />

: 70% irradiation diameter <strong>in</strong>tensity at central <strong>in</strong>tensity.<br />

Irradiation distance Irradiation distance Irradiation distance<br />

80 mm 3.150 <strong>in</strong><br />

100 mm 3.937 <strong>in</strong><br />

15<br />

0.591<br />

5 mm 0.197 <strong>in</strong><br />

10 mm 0.394 <strong>in</strong><br />

15 mm 0.591 <strong>in</strong><br />

20 mm 0.787 <strong>in</strong><br />

25 mm 0.984 <strong>in</strong><br />

30 mm 1.181 <strong>in</strong> 80 mm 3.150 <strong>in</strong><br />

40 mm 1.575 <strong>in</strong> 100 mm 3.937 <strong>in</strong><br />

50 mm 1.969 <strong>in</strong><br />

-15<br />

-0.591<br />

-10<br />

-0.394<br />

-5<br />

-0.197<br />

0<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

Irradiation area (mm <strong>in</strong>)<br />

15<br />

0.591<br />

15 mm 0.591 <strong>in</strong><br />

10 mm 0.394 <strong>in</strong><br />

20 mm 0.787 <strong>in</strong><br />

5 mm 0.197 <strong>in</strong><br />

25 mm 0.984 <strong>in</strong><br />

30 mm 1.181 <strong>in</strong><br />

40 mm 1.575 <strong>in</strong><br />

50 mm 1.969 <strong>in</strong><br />

-15<br />

-0.591<br />

-10<br />

-0.394<br />

-5<br />

-0.197<br />

0<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

15<br />

0.591<br />

Irradiation area (mm <strong>in</strong>)<br />

80 mm 3.150 <strong>in</strong><br />

100 mm 3.937 <strong>in</strong><br />

25 mm 0.984 <strong>in</strong><br />

30 mm 1.181 <strong>in</strong><br />

20 mm 0.787 <strong>in</strong><br />

20 mm 0.787 <strong>in</strong><br />

10 mm 0.394 <strong>in</strong><br />

40 mm 1.575 <strong>in</strong><br />

-15<br />

-0.591<br />

-10<br />

-0.394<br />

-5<br />

-0.197<br />

0<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

15<br />

0.591<br />

-15<br />

-0.591<br />

-10<br />

-0.394<br />

-5<br />

-0.197<br />

0<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

15<br />

0.591<br />

-15<br />

-0.591<br />

-10<br />

-0.394<br />

-5<br />

-0.197<br />

0<br />

0<br />

5<br />

0.197<br />

10<br />

0.394<br />

15<br />

0.591<br />

Irradiation area (mm <strong>in</strong>)<br />

Irradiation area (mm <strong>in</strong>)<br />

Irradiation area (mm <strong>in</strong>)<br />

5 mm 0.197 <strong>in</strong><br />

50 mm 1.969 <strong>in</strong><br />

5


Dimensions<br />

AN<strong>UP50</strong><br />

AN<strong>UP50</strong> controller<br />

201<br />

7.913<br />

140<br />

5.512<br />

10<br />

0.394<br />

130<br />

5.118<br />

165<br />

6.496<br />

Light guide fiber units<br />

Center of the light outlet<br />

(Unit: mm <strong>in</strong>) Exclud<strong>in</strong>g the protrud<strong>in</strong>g sections<br />

1000 mm 39.37 <strong>in</strong><br />

Core material: Quartz<br />

Clad material: Quartz<br />

(M<strong>in</strong>imum allowable bend<strong>in</strong>g radius: 50 mm 1.969 <strong>in</strong>)<br />

SUS flexible tube<br />

30<br />

1.181<br />

25<br />

0.984<br />

325<br />

12.795<br />

11<br />

0.433<br />

29<br />

1.142<br />

30<br />

1.181<br />

SUS mount r<strong>in</strong>g<br />

Heat ray cut filter unit Lens unit<br />

Product No. List<br />

Lamp Spot Type<br />

Controller<br />

Light guide<br />

fiber units<br />

Please contact ..........<br />

Ø59<br />

Ø2.323<br />

No. CE-<strong>UP50</strong>-1 February, 2011<br />

Light outlet end shape<br />

Without<br />

lens<br />

For AS<br />

and BS<br />

lens<br />

with lens<br />

Fiber bundle diameter:<br />

5 mm 0.197 <strong>in</strong><br />

Aicure series<br />

Fiber bundle diameter:<br />

3.5 mm 0.138 <strong>in</strong><br />

Fiber bundle diameter:<br />

8 mm 0.315 <strong>in</strong><br />

30 1.181 10 0.394<br />

25 0.984 10 0.394 22 0.866 18 0.709<br />

30 1.181 41 1.614 25 0.984 41 1.614<br />

Product name UV lamp UV irradiation Allowable number of fiber branches Power supply<br />

Product No.<br />

AN<strong>UP50</strong> controller<br />

200 W Mercury<br />

xenon lamp<br />

Bundle diameter Number of branches Product No.<br />

1 branch<br />

AN<strong>UP50</strong>31<br />

Ø3.5 mm Ø0.138 <strong>in</strong><br />

2 branches<br />

AN<strong>UP50</strong>32<br />

3 branches<br />

AN<strong>UP50</strong>33<br />

4 branches<br />

AN<strong>UP50</strong>34<br />

1 branch<br />

AN<strong>UP50</strong>51<br />

Ø5 mm Ø0.197 <strong>in</strong><br />

2 branches<br />

AN<strong>UP50</strong>52<br />

3 branches<br />

AN<strong>UP50</strong>53<br />

4 branches<br />

AN<strong>UP50</strong>54<br />

Ø8 mm Ø0.315 <strong>in</strong> 1 branch<br />

AN<strong>UP50</strong>81<br />

UV auto control,<br />

Electronically-controlled shutter<br />

Ø10 Ø14<br />

Ø0.394 Ø0.551<br />

Ø10<br />

Ø0.394<br />

Ø14<br />

Ø0.551<br />

Ø5<br />

Ø0.197<br />

Ø7<br />

Ø0.276<br />

Ø14<br />

Ø0.551<br />

1 to 4 branches<br />

Ø8 Ø9<br />

Ø0.315 Ø0.354<br />

Ø8 Ø9<br />

Ø0.315 Ø0.354<br />

Ø3.5<br />

Ø0.138<br />

Ø7<br />

Ø0.276<br />

Ø14<br />

Ø0.551<br />

90 to 264 V AC<br />

50/60 Hz 280 V A<br />

Ø16<br />

Ø0.630<br />

Ø18<br />

Ø0.709<br />

AN<strong>UP50</strong><br />

Ø8<br />

Ø0.315<br />

Ø10<br />

Ø0.394<br />

Product name Specifications Product No.<br />

Lens *<br />

Short range converg<strong>in</strong>g lens AN<strong>UP50</strong>01AS<br />

Long range converg<strong>in</strong>g lens AN<strong>UP50</strong>01BS<br />

Accessories Heat ray cut filter Reflection type<br />

AN<strong>UP50</strong>01F<br />

Goggles UV protective goggles AN<strong>UP50</strong>01SG<br />

Lamp<br />

For AN<strong>UP50</strong><br />

ANUPS204<br />

Lamp lead wire<br />

For AN<strong>UP50</strong><br />

ANUPS50H2<br />

* Please consult us separately <strong>for</strong> the lens <strong>for</strong> the Ø8 mm Ø0.315 <strong>in</strong> fiber unit.<br />

<strong>Panasonic</strong> Electric Works SUNX Co., Ltd.<br />

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan<br />

■Telephone: +81-568-33-7211 ■Facsimile: +81-568-33-2631<br />

Overseas Market<strong>in</strong>g Department<br />

■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591<br />

panasonic-electric-works.net/sunx<br />

All Rights Reserved ©<strong>Panasonic</strong> Electric Works SUNX Co., Ltd. 2011<br />

Spedfications are subject to change without notice. Pr<strong>in</strong>ted <strong>in</strong> Japan