Stable UV irradiation per<strong>for</strong>mance<br />
Programmable irradiation function<br />
This function prevents cur<strong>in</strong>g distortion and enables<br />
high-quality precision bond<strong>in</strong>g.<br />
Program mode<br />
Specifications<br />
Aicure Product No.<br />
Power supply<br />
Lamp<br />
UV <strong>in</strong>tensity<br />
STEP=1<br />
Lamp Product No.<br />
Pattern 0<br />
STEP=2<br />
STEP=3<br />
Interval (closed)<br />
STEP=5<br />
Interval (closed)<br />
AN<strong>UP50</strong><br />
STEP=7<br />
90 to 264 V AC 50/60 Hz 280 V A<br />
ANUPS204<br />
Time<br />
…<br />
200 W mercury xenon lamp, preset quickly-attachable type<br />
* Average life of 3,000 hours: Ratio to the <strong>in</strong>itial UV <strong>in</strong>tensity --<br />
80% or higher <strong>in</strong> a vertical position, 70% or higher <strong>in</strong> a horizontal<br />
position (when the auto control function is off)<br />
* Guaranteed life: 2,000 hours<br />
Pattern 9<br />
Time<br />
The irradiation can be programmed to controls the irradiation power and time<br />
depend<strong>in</strong>g on the res<strong>in</strong> and cur<strong>in</strong>g appication, support<strong>in</strong>g high-quality and<br />
high-precision bond<strong>in</strong>g with m<strong>in</strong>imum cure shr<strong>in</strong>kage. In addition to the simple<br />
irradiation mode which irradiation is cont<strong>in</strong>uously per<strong>for</strong>med at a constant<br />
<strong>in</strong>tensity, up to 10 steps 10 patterns can be set. This <strong>in</strong>cludes the step-up<br />
mode which the <strong>in</strong>tensity is changed over time and the <strong>in</strong>terval mode which<br />
irradiation is per<strong>for</strong>med at specified <strong>in</strong>tervals.<br />
Digital sett<strong>in</strong>g allows <strong>for</strong> consistency of set<br />
values from operator to operator.<br />
The irradiation power can be f<strong>in</strong>ely set <strong>in</strong> the range of 0 to 100% <strong>in</strong><br />
<strong>in</strong>crements of 0.5%. The actual UV irradiation <strong>in</strong>tensity is approximately<br />
proportional to the displayed value, mak<strong>in</strong>g the sett<strong>in</strong>g work easier and more<br />
accurate.<br />
Interchangeability with ANUP5204<br />
The wavelength distribution (typical characteristics) of <strong>UP50</strong> is identical to<br />
ANUP5204, our exist<strong>in</strong>g model. The replacement lamp, the ANUPS204, is<br />
also the same as that <strong>for</strong> the ANUP5204.<br />
STEP=1<br />
STEP=10<br />
Easy to <strong>in</strong>stall<br />
Can be placed either<br />
vertically or horizontally .<br />
The unit can be placed <strong>in</strong> either a vertical<br />
position that makes the footpr<strong>in</strong>t smaller<br />
or a horizontal position that allows<br />
stack<strong>in</strong>g other units.<br />
Long life, quickly-attachable lamp<br />
The average lamp life is 3,000 hours<br />
(guaranteed life: 2,000 hours*). The lamp<br />
can be easily replaced with a s<strong>in</strong>gle<br />
operation and does not require an optical<br />
axis adjustment.<br />
* Ratio to the <strong>in</strong>itial UV <strong>in</strong>tensity -- 80% or higher <strong>in</strong><br />
vertical placement, 70% or higher <strong>in</strong> horizontal placement<br />
Two lens unit models <strong>for</strong> short and long range<br />
converg<strong>in</strong>g<br />
The two lens unit models, one <strong>for</strong> short range and the other <strong>for</strong> long range<br />
converg<strong>in</strong>g, cover a variety of applications and work pieces.<br />
Slim AS and<br />
BS lens units<br />
UV irradiation<br />
Shutter<br />
Sett<strong>in</strong>g<br />
External signal<br />
Dimensions<br />
Input<br />
Output<br />
Light guide fiber<br />
Please refer to page 5 <strong>for</strong> the UV <strong>in</strong>tensity distribution data.<br />
Aicure <strong>UP50</strong><br />
AS lens<br />
Short range<br />
converg<strong>in</strong>g lens<br />
BS lens<br />
Long range<br />
converg<strong>in</strong>g lens<br />
UV <strong>in</strong>tensity adjustment by digital sett<strong>in</strong>g (0 to 100%, <strong>in</strong> <strong>in</strong>crements of 0.5%)<br />
UV auto control<br />
Programmable irradiation (10 steps <strong>in</strong> each of 10 patterns)<br />
External signal control: Turn<strong>in</strong>g the lamp on/off, manual open<strong>in</strong>g/clos<strong>in</strong>g<br />
of the shutter, start<strong>in</strong>g programmed pattern irradiation, start<strong>in</strong>g<br />
timer-controlled irradiation, and execut<strong>in</strong>g calibration<br />
Electronically-controlled shutter us<strong>in</strong>g manual or timer-controlled operation<br />
Digital sett<strong>in</strong>g us<strong>in</strong>g membrane switches<br />
Open<strong>in</strong>g/clos<strong>in</strong>g the shutter (timer/manual), light<strong>in</strong>g the lamp<br />
Light<strong>in</strong>g the lamp, stabiliz<strong>in</strong>g the lamp light, open<strong>in</strong>g the shutter,<br />
outputt<strong>in</strong>g error signals, and <strong>in</strong>dicat<strong>in</strong>g the lamp life<br />
165 × 201 × 325 mm 6.496 × 7.913 × 12.795 <strong>in</strong> (Exclud<strong>in</strong>g protrud<strong>in</strong>g sections)<br />
Weight<br />
8 kg approx.<br />
Please refer to page 4 <strong>for</strong> the light guide fiber units and other optional parts.<br />
(Vertical placement)<br />
3