01.02.2013 Views

datasheets - DAMAC

datasheets - DAMAC

datasheets - DAMAC

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VRT 5I<br />

VRT 8I<br />

Ü Model 5 A/1 kW or 8 A / 1.6 kW<br />

Design and Manufacture of Voltage Regulators<br />

and Electronic Components<br />

SINGLE-PHASE VOLTAGE<br />

REGULATORS<br />

Ü Microprocessor-controlled start-up<br />

Ü Microprocessor-controlled<br />

set point variation<br />

Ü On/Off switch independent of the setpoint<br />

Ü Adjustable minimum output voltage<br />

Ü Overvoltage and overload protection<br />

Ü EMC fi ltering<br />

Ü IP 54 Protection<br />

GENERAL DESCRIPTION<br />

VRT *I operate on the principle of conduction angle. A microprocessor based control system provides optimal<br />

control of the power semiconductor, increasing the range and stability of the output voltage.<br />

VRT *I applications include :<br />

Temperature control.<br />

Fan speed control.<br />

Range control for vibrating appliances.<br />

Speed variation on universal, asynchronous and phase angle<br />

motors.<br />

Light intensity control.<br />

Current or voltage control on battery charger.<br />

Voltage regulators are suitable replacements for autotransformers and step-down converters in applications that<br />

support the phase cutting principle.<br />

damac<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

Tél +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr


Ver. 2.00 - june 2008 / graphic design & photography © Stephanpelissier 2008<br />

SPECIFICATIONS<br />

POWER SUPPLY<br />

Voltage 230 Vac ± 15 %<br />

Frequency 50 Hz ± 2 Hz<br />

Power consumption (without charge) 30 mA<br />

Protection Overvoltage / overload<br />

LOAD OUTPUT<br />

Voltage From 0 to 98 % of power supply<br />

Halfwave or fullwave<br />

Frequency 50 Hz ± 2 Hz<br />

OPERATING/STORAGE TEMPERATURES<br />

Storage temperature range -10 °C to +60 °C<br />

Operating temperature range -10 °C to +45 °C<br />

MECHANICAL ENVIRONMENT<br />

Protection IP 54 (EN 60-529)<br />

Dimensions VRT 5I 145 x 128 x 84 mm<br />

Dimensions VRT 8I 145 x 128 x 98 mm<br />

Material ABS UL94-V0<br />

Color RAL 9010<br />

Connection Cable 3 x 2.5 mm² max<br />

Fixing 4 screws, max diameter 4 mm<br />

Compliance with EMC directive 89/336/CEE<br />

Compliance with LV directive 73/23/CEE<br />

CONNECTION<br />

SUMMARY<br />

����� � ����<br />

������ � �������<br />

����� � �����<br />

���������� � ����������<br />

������ � ����<br />

SIZE<br />

����� � ����<br />

������ � �������<br />

����� � �����<br />

���������� � ����������<br />

������ � ����<br />

Reference Power Max current Fuse Weight<br />

VRT 5I 1000 W 5 A 5 x 20 mm 6.3 A Type T 0.480 Kg<br />

VRT 8I 1600 W 8 A 5 x 20 mm 10.0 A Type T 0.620 Kg<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

VRT 5I / VRT 8I<br />

���� ������<br />

Tél. +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr<br />

Dimensions in millimeters


VRT 3V<br />

VRT 5V<br />

VRT 8V<br />

Design and Manufacture of Voltage Regulators<br />

and Electronic Components<br />

SINGLE-PHASE VOLTAGE<br />

REGULATORS<br />

Ü Model 3 A/0.6 kW or 5 A/1 kW or 8 A/1.6 kW<br />

Ü Microprocessor-controlled start-up<br />

Ü Microprocessor-controlled set point<br />

variation<br />

Ü On/Off switch independent of set point<br />

Ü Adjustable minimum voltage<br />

Ü Overvoltage and overload protection<br />

Ü EMC fi ltering<br />

Ü IP 54 Protection<br />

GENERAL DESCRIPTION<br />

VRT *V operate on the principle of conduction angle. A microprocessor based control system provides optimal<br />

control of the power semiconductor, increasing the range and stability of the output voltage.<br />

VRT *V are designed to control electric fans and ventilation units. Their specifi c start cycle produces rapid<br />

airfl ow.<br />

Voltage (volt)<br />

230<br />

120<br />

Set point<br />

Start-up delay<br />

Time to reach set point<br />

1 2 3 4 5 6 7 8 9 10<br />

Time (second)<br />

damac<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

Tél +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr


Ver. 2.00 - june 2008 / graphic design & photography © Stephanpelissier 2008<br />

SPECIFICATIONS<br />

POWER SUPPLY<br />

Voltage 230 Vac ± 15 %<br />

Frequency 50 Hz ± 2 Hz<br />

Power consumption (without charge) 30 mA<br />

Protection Overvoltage / overload<br />

LOAD OUTPUT<br />

Voltage From 0 to 98 % of power supply<br />

Frequency 50 Hz ± 2 Hz<br />

OPERATING/STORAGE TEMPERATURES<br />

Storage temperature range -10 °C to +60 °C<br />

Operating temperature range -10 °C to +45 °C<br />

MECHANICAL ENVIRONMENT<br />

Protection IP 54 (EN 60-529)<br />

Dimensions VRT 3V 145 x 128 x 84 mm<br />

Dimensions VRT 5V 145 x 128 x 84 mm<br />

Dimensions VRT 8V 145 x 128 x 98 mm<br />

Material ABS UL94-V0<br />

Color RAL 9010<br />

Connection Cable 3 x 2.5 mm² max<br />

Fixing 4 screws, max diameter 4 mm<br />

Compliance with EMC directive 89/336/CEE<br />

Compliance with LV directive 73/23/CEE<br />

CONNECTION<br />

SUMMARY<br />

����� � ����<br />

������ � �������<br />

����� � �����<br />

���������� � ����������<br />

������ � ����<br />

���<br />

��� ���<br />

�<br />

� �<br />

�<br />

�<br />

SIZE<br />

Reference Power Max current Fuse Weight<br />

VRT 3V 600 W 3 A 5 x 20 mm 3.15 A Type T 0.450 Kg<br />

VRT 5V 1000 W 5 A 5 x 20 mm 6.3 A Type T 0.480 Kg<br />

VRT 8V 1600 W 8 A 5 x 20 mm 10.0 A Type T 0.620 Kg<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

VRT 3V / VRT 5V / VRT 8V<br />

���<br />

��� ���<br />

�<br />

� �<br />

�<br />

�<br />

���� ������<br />

Tél. +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr<br />

Dimensions in millimeters


VRT 3VIL<br />

VRT 5VIL<br />

VRT 8VIL<br />

Design and Manufacture of Voltage Regulators<br />

and Electronic Components<br />

SINGLE-PHASE VOLTAGE<br />

REGULATORS<br />

Ü Model 3 A/0.6 kW or 5 A/1 kW or 8 A/1.6 kW<br />

Ü Microprocessor-controlled start-up<br />

Ü Microprocessor-controlled set point<br />

variation<br />

Ü On/Off switch for lighting control<br />

Ü Adjustable minimum voltage<br />

Ü Overvoltage and overload protection<br />

Ü EMC fi ltering<br />

Ü IP 54 Protection<br />

GENERAL DESCRIPTION<br />

VRT *VIL operate on the principle of conduction angle. A microprocessor based control system provides optimal<br />

control of the power semiconductor, increasing the range and stability of the output voltage.<br />

VRT *VIL are designed to control electric fans and ventilation units. Their specifi c start cycle produces rapid<br />

airfl ow.<br />

VRT *VIL have an additional on/off switch controlling a 230 Vac supply that can be used for kitchen hood lighting<br />

or other auxiliaries.<br />

Voltage (volt)<br />

230<br />

120<br />

Set point<br />

Start-up delay<br />

Time to reach set point<br />

1 2 3 4 5 6 7 8 9 10<br />

Time (second)<br />

damac<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

Tél +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr


Ver. 2.00 - june 2008 / graphic design & photography © Stephanpelissier 2008<br />

SPECIFICATIONS<br />

POWER SUPPLY<br />

Voltage 230 Vac ± 15 %<br />

Frequency 50 Hz ± 2 Hz<br />

Power consumption (without charge) 30 mA<br />

Protection Overvoltage / overload<br />

LOAD OUTPUT<br />

Voltage From 0 to 98 % of power supply<br />

Frequency 50 Hz ± 2 Hz<br />

OPERATING/STORAGE TEMPERATURES<br />

Storage temperature range -10 °C to +60 °C<br />

Operating temperature range -10 °C to +45 °C<br />

MECHANICAL ENVIRONMENT<br />

Protection IP 54 (EN 60-529)<br />

Dimensions VRT 3VIL 145 x 128 x 84 mm<br />

Dimensions VRT 5VIL 145 x 128 x 84 mm<br />

Dimensions VRT 8VIL 145 x 128 x 98 mm<br />

Material ABS UL94-V0<br />

Color RAL 9010<br />

Connection Cable 3 x 2.5 mm² max<br />

Fixing 4 screws, max diameter 4 mm<br />

Compliance with EMC directive 89/336/CEE<br />

Compliance with LV directive 73/23/CEE<br />

CONNECTION<br />

����<br />

�������<br />

����� ����<br />

SUMMARY<br />

����<br />

�������<br />

����<br />

�������<br />

�������<br />

�����<br />

����<br />

��������<br />

���<br />

�<br />

� �<br />

�<br />

�<br />

SIZE<br />

Reference Power Max current Fuse Weight<br />

VRT 3VIL 600 W 3 A 5 x 20 mm 3.15 A Type T 0.450 Kg<br />

VRT 5VIL 1000 W 5 A 5 x 20 mm 6.3 A Type T 0.480 Kg<br />

VRT 8VIL 1600 W 8 A 5 x 20 mm 10.0 A Type T 0.620 Kg<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

VRT 3VIL / VRT 5VIL / VRT 8VIL<br />

���� ������<br />

Tél. +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr<br />

Dimensions in millimeters


Design and Manufacture of Voltage Regulators<br />

and Electronic Components<br />

VRT 6-A1 SINGLE-PHASE VOLTAGE<br />

REGULATOR WITH ANALOG<br />

SET POINT<br />

Ü Output voltage adjusted by 0-10 V<br />

or 4-20 mA set point<br />

Ü External On/Off switch by contact<br />

or 3-wire PNP sensor<br />

Ü Auxiliary power output 24 Vdc/120 mA<br />

Ü Model 6 A/1.2 kW<br />

Ü Overvoltage and overload protection<br />

Ü EMC fi ltering<br />

Ü IP 54 Protection<br />

GENERAL DESCRIPTION<br />

VRT 6-A1 operates on the principle of conduction angle. A microprocessor based control system provides optimal<br />

control of the power semiconductor, increasing the range and stability of the output voltage.<br />

A 0-10 V or 4-20 mA analog signal controls the output voltage level, allowing the VRT 6-A1 to be confi gured for a<br />

wide range of applications.<br />

VRT 6-A1 applications include :<br />

Temperature control.<br />

Fan speed control.<br />

Range control for vibrating appliances.<br />

Speed variation on universal, asynchronous and phase angle motors.<br />

Light intensity control.<br />

Current or voltage control on battery charger.<br />

Voltage regulators are suitable replacements for autotransformers and step-down converters in applications<br />

that support the phase cutting principle.<br />

damac<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

Tél +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr


Ver. 2.00 - june 2008 / graphic design & photography © Stephanpelissier 2008<br />

SPECIFICATIONS<br />

POWER SUPPLY LOAD OUTPUT<br />

Voltage 230 Vac ± 15 % Voltage From 0 to 98 % of power supply<br />

Frequency 50 Hz ± 2 Hz Frequency 50 Hz ± 2 Hz<br />

Power consumption (without load) 70 mA Current 6 A max<br />

Protection Overvoltage / overload<br />

INPUT 0-10 Vdc INPUT 4-20 mA<br />

Input voltage From 0 to 10 Vdc Input current From 0 to 20 mA<br />

Transfer characteristics Linearized Transfer characteristics Linearized<br />

AUXILIARY POWER OUTPUT 24 Vdc OPERATING AND STORAGE TEMPERATURES<br />

Output voltage 24 Vdc regulated Storage temperature range -10 °C to +60 °C<br />

Maximum output current 120 mA Operating temperature range -10 °C to +45 °C<br />

Protection Short circuit and reversal<br />

MECHANICAL ENVIRONMENT<br />

Protection IP 54 (EN 60-529)<br />

Dimensions 145 x 128 x 62 mm<br />

Material ABS UL94-V0<br />

Color RAL 9010<br />

Power connection Cable 3 x 2.5 mm² max<br />

Control connection Cable 3 x 1.5 mm² max<br />

Fixing 4 screws, max diameter 4 mm<br />

Compliance with EMC directive 89/336/CEE<br />

Compliance with LV directive 73/23/CEE<br />

SCHEMATIC PRINCIPLE<br />

����������<br />

������ �����<br />

��� ��� � �� ��<br />

WORKING PRINCIPLES<br />

SIZE<br />

����� ���� � ����� ����� ���� � �������<br />

�<br />

���� �������<br />

�� � ���<br />

��������<br />

����� �������<br />

���� �������<br />

External input LED<br />

E3 E2 Marche Forçage<br />

Off Off Voltage regulator off (1)<br />

On Off Voltage regulator on (2)<br />

X On On Forced full voltage ouput (3)<br />

3, Allée des Fleurs BP 36<br />

38241 MEYLAN Cedex<br />

FRANCE<br />

����� �������<br />

�� ����� ���������<br />

Function<br />

VRT 6 - A1<br />

���� ������<br />

Dimensions in millimeters<br />

������ �����<br />

��� �����<br />

���� ������ ��<br />

X = don’t care.<br />

(1) Regulator is stopped by the external on/off input. (2) Regulator is started by the external on/off input. Voltage changes according<br />

to the set point between set minimum and maximum values. (3) Regulator delivers maximum preset voltage.<br />

Tél. +33 (0)4 76 90 68 63<br />

Fax +33 (0)4 76 41 03 54<br />

E-mail : info@damac.fr<br />

http://www.damac.fr