technical hotline +44 (0)1268 563720 perimeter and distribution | cable management<br />

<strong>Powerlink</strong> <strong>Plus</strong> is a busbar trunking system developed<br />

to meet the power and data distribution needs of<br />

offices, schools and laboratories.<br />

A comprehensive range of unique flush fitting<br />

accessories and gently curved covers combine to create a<br />

visually unrivalled installation. The system offers flexibility<br />

to easily adapt to future needs for the installer.<br />

range introduction features and benefits<br />

<strong>Powerlink</strong> <strong>Plus</strong><br />

choice of 3 profiles<br />

To suit all your skirting and dado requirements<br />

One-piece corner, couplers and end cap covers<br />

Simplifies installation and improves aesthetics<br />

333<br />

63a busbar for plug-on accessories and high protective<br />

conductor current compliance<br />

Quick and easy installation, eliminating the requirement for hard wiring<br />

Unique flush fitting accessories<br />

Provide an unobtrusive finish<br />

Pre-drilled trunking bases<br />

Eliminates the need to measure and drill fixing holes on site thus reducing<br />

installation time<br />

large data cabling capability in outer compartments<br />

For all your communication and data requirements<br />

EMc Screening<br />

Provides an effective screen for computer service cables<br />

Made from 100% Pvcu<br />

<strong>Powerlink</strong> <strong>Plus</strong> is both robust and easily workable on site<br />

all extrusions manufactured from 90% recycled material*<br />

* Based on 2008 consumption.


334 <strong>Powerlink</strong> <strong>Plus</strong><br />

cable management | perimeter and distribution www.mkelectric.co.uk<br />

accESSOry SPacEr<br />

For mounting accessories as pairs or any<br />

number of in-line multiples.<br />

One supplied with each 13A socket accessory.<br />

ChoICe oF DeLIveRy<br />

with <strong>Powerlink</strong> <strong>Plus</strong> the choice is yours – hard<br />

wiring or an integral 63A busbar with power<br />

accessories that simply plug into place.<br />

PrE-WirEd<br />

cablE aSSEMbly<br />

For electrical<br />

connection of<br />

busbar around<br />

corners.<br />

inTErnal<br />

cOrnEr<br />

Supplied with<br />

carrier, busbar<br />

shield and outer<br />

clip-on cover.<br />

ExTErnal cOrnEr<br />

Supplied with carrier,<br />

busbar shield and<br />

outer clip-on cover.<br />

FlUSh FiTTinG accESSOriES<br />

<strong>Powerlink</strong> <strong>Plus</strong> offers a wide<br />

selection of flush fitting<br />

accessories, including switch<br />

sockets, DP switches, connection<br />

units and virtually every type<br />

of computer and telecom<br />

connector. All power accessories<br />

are available as plug-on units<br />

or with wire-in terminals. If<br />

that is not enough, an optional<br />

mounting kit will accept virtually<br />

any accessory within the entire<br />

<strong>MK</strong> range.


<strong>Powerlink</strong> <strong>Plus</strong><br />

technical hotline +44 (0)1268 563720 perimeter and distribution | cable management<br />

Mcb/rcd<br />

Housing mounts<br />

directly to central<br />

compartment and<br />

accepts any one<br />

or two module<br />

product from the<br />

<strong>MK</strong> Sentry range<br />

(excluding RCBOs).<br />

End caP<br />

Neatly finishes runs of trunking.<br />

Supplied with screw fix carrier/busbar<br />

shield and clip-on cover.<br />

cOUPlEr<br />

Joins trunking lengths together and<br />

to pre-assembled angles, crossovers<br />

or special corners. Supplied with<br />

busbar shield.<br />

EMc ScrEEninG<br />

Aluminium screening<br />

inserts provide effective<br />

screening for computer<br />

services cables.<br />

335


336 <strong>Powerlink</strong> <strong>Plus</strong><br />

cable management | perimeter and distribution www.mkelectric.co.uk<br />

Component Selector Chart<br />

PRoFILe LengThS<br />

Trunking Coupler end Caps<br />

Standard length: 3 metres<br />

Supplied with covers<br />

Trunking size: 170mm (Height) x 50mm (Depth)<br />

With extension fitted:<br />

212mm (Height) x 50mm (Depth)<br />

Material PVCu<br />

Colour: White and Charcoal<br />

DADo<br />

TRunKIng<br />

wITh<br />

BuSBARS<br />

DADo<br />

TRunKIng<br />

wIThouT<br />

BuSBARS<br />

SKIRTIng<br />

AnD DADo<br />

TRunKIng<br />

wITh<br />

BuSBARS<br />

SKIRTIng<br />

AnD DADo<br />

TRunKIng<br />

wIThouT<br />

BuSBARS<br />

eXTenSIon FoR<br />

SKIRTIng AnD<br />

DADo TRunKIng<br />

wITH AND<br />

wITHOUT<br />

63 AMP<br />

BUSBARS<br />

K1963WHI<br />

K1963CHA<br />

K1903WHI<br />

K1903CHA<br />

K1962WHI<br />

K1962CHA<br />

K1902WHI<br />

K1902CHA<br />

K1913WHI<br />

K1913CHA<br />

wITH BUSBAR<br />

SHIELD<br />

K1908WHI<br />

K1908CHA<br />

K1908WHI<br />

K1908CHA<br />

K1945WHI<br />

K1945CHA<br />

K1945WHI<br />

K1945CHA<br />

K1918WHI<br />

K1918CHA<br />

SUPPLIED<br />

AS A PAIR<br />

K1904WHI<br />

K1904CHA<br />

K1904WHI<br />

K1904CHA<br />

K1944WHI<br />

K1944CHA<br />

K1944WHI<br />

K1944CHA<br />

K1914WHI<br />

K1914CHA


<strong>Powerlink</strong> <strong>Plus</strong><br />

technical hotline +44 (0)1268 563720 perimeter and distribution | cable management<br />

FITTIngS<br />

Internal<br />

Corner<br />

wITH BUSBAR<br />

SHIELD<br />

K1905WHI<br />

K1905CHA<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1905WHI<br />

K1905CHA<br />

K1911WHI<br />

K1911CHA<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1911WHI<br />

K1911CHA<br />

K1915WHI<br />

K1915CHA<br />

external<br />

Corner<br />

wITH BUSBAR<br />

SHIELD<br />

K1906WHI<br />

K1906CHA<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1906WHI<br />

K1906CHA<br />

K1912WHI<br />

K1912CHA<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1912WHI<br />

K1912CHA<br />

K1916WHI<br />

K1916CHA<br />

Internal<br />

Special<br />

Corner<br />

allows continuous<br />

installation around corners<br />

other than 90º.<br />

to order, quote list no. and<br />

angle eg. K1966wHi 150º.<br />

K1965WHI<br />

K1965CHA<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1965WHI<br />

K1965CHA<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

K1961WHI<br />

K1961CHA<br />

Requires 2 x K1945<br />

couplers to join to trunking<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1961WHI<br />

K1961CHA<br />

Requires 2 x K1945<br />

couplers to join to trunking<br />

K1967WHI<br />

K1967CHA<br />

Requires 2 x K1918<br />

couplers to join to trunking<br />

external<br />

Special<br />

Corner<br />

allows continuous<br />

installation around corners<br />

other than 90º.<br />

to order, quote list no. and<br />

angle eg. K1966wHi 150º.<br />

K1966WHI<br />

K1966CHA<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1966WHI<br />

K1966CHA<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

K1964WHI<br />

K1964CHA<br />

Requires 2 x K1945<br />

couplers to join to trunking<br />

K1968WHI<br />

K1968CHA<br />

Requires 2 x K1918<br />

couplers to join to trunking<br />

Internal<br />

135º<br />

Corner<br />

K1965WHI135<br />

K1965CHA135<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1965WHI135<br />

K1965CHA135<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

K1961WHI135<br />

Requires 2 x K1945<br />

couplers to join to trunking<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1961WHI135<br />

K1961CHA135<br />

Requires 2 x K1945<br />

couplers to join to trunking<br />

K1967WHI135<br />

Requires 2 x K1918<br />

couplers to join to trunking<br />

external<br />

135º<br />

Corner<br />

K1966WHI135<br />

K1966WHI135<br />

337<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

Requires 2 x K1908<br />

couplers to join to trunking<br />

K1964WHI135<br />

K1964CHA135<br />

Requires 2 x K1945<br />

couplers to join to trunking<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1968WHI135<br />

Requires 2 x K1918<br />

couplers to join to trunking


338 <strong>Powerlink</strong> <strong>Plus</strong><br />

cable management | perimeter and distribution www.mkelectric.co.uk<br />

dAdo<br />

Trunking<br />

WiTh<br />

BusBArs<br />

dAdo<br />

Trunking<br />

WiThouT<br />

BusBArs<br />

skirTing<br />

And dAdo<br />

Trunking<br />

WiTh BusBArs<br />

skirTing<br />

And dAdo<br />

Trunking<br />

WiThouT<br />

BusBArs<br />

eXTenSIon FoR<br />

SKIRTIng AnD<br />

DADo TRunKIng<br />

Flat Angle Flat Tee<br />

K1992WHI<br />

K1992CHA<br />

UP/DOWN<br />

Requires 1 x 1919 Cable link<br />

assembly<br />

K1992WHI<br />

K1992CHA<br />

UP/DOWN<br />

K1957WHI<br />

K1957CHA<br />

UP<br />

K1958WHI<br />

K1958CHA<br />

DOWN<br />

Requires 1 x 1919 Cable link assembly<br />

K1957WHI<br />

K1957CHA<br />

UP<br />

K1958WHI<br />

K1958CHA<br />

DOWN<br />

K1994WHI<br />

K1994CHA<br />

UP<br />

K1993WHI<br />

K1993CHA<br />

DOWN<br />

K1973WHI<br />

K1973CHA<br />

UP<br />

K1972WHI<br />

K1972CHA<br />

DOWN<br />

Requires 2 x 1919 Cable link<br />

assembly<br />

K1973WHI<br />

K1973CHA<br />

UP<br />

K1972WHI<br />

K1972CHA<br />

DOWN<br />

Flat Cross Cable<br />

Retainers<br />

K1974WHI<br />

K1974CHA<br />

K1974WHI<br />

K1974CHA<br />

vTS11<br />

vTS12<br />

VTS11WHI<br />

CaBle RetaineRS<br />

FoR uSe witH<br />

extenSion<br />

tRunKinG<br />

VTS12WHI<br />

CaBle RetaineRS<br />

FoR uSe in outeR<br />

ComPaRtmentS


<strong>Powerlink</strong> <strong>Plus</strong><br />

technical hotline +44 (0)1268 563720 perimeter and distribution | cable management<br />

SPAReS<br />

Cable entry<br />

Section<br />

K1920wHI<br />

K1920CHA<br />

K1929wHI<br />

K1929CHA<br />

K1920WHI<br />

K1920CHA<br />

ReaR CaBle<br />

entRy SeCtion<br />

DaDo tRunKinG<br />

K1929WHI<br />

K1929CHA<br />

ReaR CaBle<br />

entRy SeCtion<br />

SKiRtinG anD<br />

DaDo tRunKinG<br />

Predrilled with knockouts<br />

in upper and lower<br />

compartments and single<br />

large aperture in the central<br />

compartment.<br />

Supplied complete with<br />

covers, central cover fixing<br />

screws, and general fixing<br />

screw bushes.<br />

tRunKinG SiZe:<br />

152 (length) x 170 (Height)<br />

x 50mm (Depth)<br />

Cable entry<br />

Box<br />

FLUSH<br />

1922ALM<br />

1922ALM<br />

CaBle entRy Box<br />

FoR uSe witH<br />

K1920 anD K1929<br />

three compartment<br />

flush mounted box with<br />

adjustable plate.<br />

included in the pack is a<br />

template for positioning on<br />

site prior to the trunking<br />

being installed.<br />

DimenSionS:<br />

133 x 133 x 40mm<br />

KnoCKoutS:<br />

4 x 20mm<br />

4 x 25mm<br />

MCB/RCD<br />

housing<br />

K1949wHI<br />

K1949CHA<br />

K1949WHI<br />

K1949CHA<br />

mounts directly to the centre<br />

compartment to accept up<br />

to 2 one module products<br />

from the mK Sentry range<br />

(except RCBos).<br />

DimenSionS:<br />

220mm (length) x<br />

100mm (Depth)<br />

when mounted on trunking.<br />

Mini<br />

Trunking<br />

Adaptors<br />

K1926WHI<br />

yt4mini tRunKinG<br />

aDaPtoR<br />

K1927WHI<br />

K1927CHA<br />

mini tRunKinG<br />

aDaPtoR<br />

FoR uSe witH yea<br />

aDaPtoRS FoR yt1, yt2<br />

anD yt3 tRunKinG<br />

accepts mK ega mini<br />

trunking adaptors.<br />

Conduit<br />

Adaptors<br />

K1926wHI K1901wHI<br />

K1927wHI<br />

K1907wHI<br />

K1901WHI<br />

20mm ConDuit<br />

aDaPtoR<br />

K1907WHI<br />

25mm ConDuit<br />

aDaPtoR<br />

Covers<br />

and<br />

Cable<br />

Divider<br />

3 METRE<br />

LENGTHS<br />

K1932wHI<br />

K1935wHI<br />

1934wHI<br />

K1936wHI<br />

339<br />

K1932WHI<br />

K1932CHA<br />

outeR CoVeR<br />

SquaRe<br />

SuPPlieD in<br />

3 metRe lenGtHS<br />

K1935WHI<br />

K1935CHA<br />

outeR CoVeR<br />

CuRVeD<br />

SuPPlieD in<br />

3 metRe lenGtHS<br />

1934WHI<br />

1934CHA<br />

CentRal CoVeR<br />

StRaiGHt<br />

SuPPlieD in<br />

3 metRe lenGtHS<br />

K1936WHI<br />

K1936CHA<br />

extenSion CoVeR<br />

SuPPlieD in<br />

3 metRe lenGtHS<br />

VTS50WHI<br />

ComPaRtment DiViDeR<br />

SuPPlieD in<br />

3 metRe lenGtHS


340 <strong>Powerlink</strong> <strong>Plus</strong><br />

cable management | perimeter and distribution www.mkelectric.co.uk<br />

Socket outlets<br />

‘PLUG-ON’<br />

13 AMP<br />

STANDARD<br />

1956WHI<br />

1956CHA<br />

StanDaRD<br />

SoCKet outlet<br />

For plugging onto the busbars.<br />

Supplied complete with one<br />

accessory spacer and fixing screws.<br />

Switchsocket<br />

outlets<br />

‘PLUG-ON’<br />

13 AMP<br />

STANDARD<br />

1950WHI<br />

1950CHA<br />

StanDaRD SwitCHSoCKet<br />

witH neon<br />

1951WHI<br />

1951CHA<br />

StanDaRD SwitCHSoCKet<br />

For plugging onto the busbars.<br />

Supplied complete with one<br />

accessory spacer and fixing screws.<br />

‘PLUG-ON’<br />

13 AMP<br />

NON STANDARD<br />

1953WHI<br />

1953CHA<br />

non StanDaRD<br />

SwitCHSoCKet<br />

For plugging onto the busbars.<br />

with a ‘t’ shape earth pin aperture<br />

and for use only with the non<br />

standard 13a Safetyplug,<br />

list no. 647. Supplied complete<br />

with one accessory spacer and<br />

fixing screws.<br />

‘wIRE-IN’<br />

13 AMP<br />

STANDARD<br />

1956wHI 1950wHI 1953wHI<br />

1952wHI<br />

1956CHA 1950CHA<br />

1951wHI<br />

1951CHA<br />

1953CHA<br />

1952CHA<br />

1952WHI<br />

1952CHA<br />

StanDaRD SwitCHSoCKet<br />

Fitted with screw terminals for<br />

independent wiring. Supplied<br />

complete with one accessory<br />

spacer and fixing screws.<br />

‘wIRE-IN’<br />

13 AMP<br />

NON STANDARD<br />

1955wHI<br />

1955CHA<br />

1955WHI<br />

1955CHA<br />

non StanDaRD<br />

SiDe wiReD SwitCHSoCKet<br />

Fitted with screw terminals for<br />

independent wiring. with a ‘t’<br />

shape earth pin aperture and for<br />

use only with the non standard<br />

13a Safetyplug, list no. 647.<br />

Supplied complete with one<br />

accessory spacer and<br />

fixing screws.


<strong>Powerlink</strong> <strong>Plus</strong><br />

technical hotline +44 (0)1268 563720 perimeter and distribution | cable management<br />

Connection<br />

units<br />

DP SwITCHED<br />

‘PLUG-ON’<br />

1970WHI<br />

1970CHA<br />

witH neon anD<br />

13a FuSe<br />

1971WHI<br />

1971CHA<br />

witH neon<br />

Flex outlet anD<br />

13a FuSe<br />

For feeding from the busbars and<br />

controlling remote equipment.<br />

Supplied complete with<br />

fixing screws.<br />

DP Switches<br />

32 AMP<br />

‘PLUG-ON’<br />

Two way<br />

Switch<br />

20 AMP SP<br />

1970CHA 1943wHI 1942wHI<br />

1971wHI 1943CHA 1942CHA<br />

1943WHI<br />

1943CHA<br />

witH neon<br />

For plugging onto the busbars.<br />

Can be used either as a busbar<br />

switch disconnector or for feeding<br />

and controlling remote equipment.<br />

the switch can accommodate up to<br />

10mm 2 cables. Supplied complete<br />

with fixing screws.<br />

1942WHI<br />

1942CHA<br />

Can be used for lighting and<br />

remote equipment. it is not<br />

connected to the busbars and<br />

requires separate cables. Supplied<br />

complete with fixing screws.<br />

Telephone<br />

Socket<br />

outlets<br />

1980WHI<br />

1980CHA<br />

maSteR SoCKet<br />

1995WHI<br />

1995CHA<br />

HanDSet PolaRiSeD<br />

SoCKet outlet<br />

1999WHI<br />

1999CHA<br />

RJ11<br />

telePHone/Data SoCKet<br />

1980 Supplied complete with<br />

enclosure box together with fixing<br />

screws, connecting tool, cable tie<br />

and fixing screws for mounting on<br />

to the dado trunking. a full list of<br />

instructions with wiring diagrams is<br />

supplied in every pack. approved<br />

for use with telecommunication<br />

systems run by Bt in accordance<br />

with the conditions in the<br />

instructions for use.<br />

1995 Supplied complete with<br />

enclosure box together with fixing<br />

screws, connecting tool, cable tie<br />

and fixing screws for mounting on<br />

to the dado trunking. approved<br />

for use with telecommunication<br />

branch systems in accordance<br />

with the conditions in the<br />

instructions for use.<br />

Isolated<br />

Co-axial<br />

Socket<br />

outlets<br />

1980wHI 1981wHI<br />

1980CHA<br />

1995wHI<br />

1995CHA<br />

1981WHI<br />

1981CHA<br />

1981CHA<br />

341<br />

isolated single co-axial outlet for<br />

direct connection to single tV or<br />

Fm co-axial down lead. Supplied<br />

complete with enclosure box<br />

together with all the necessary<br />

fixing screws for mounting on<br />

to the dado trunking.


342 <strong>Powerlink</strong> <strong>Plus</strong><br />

cable management | perimeter and distribution www.mkelectric.co.uk<br />

Data outlets<br />

RJ45 BNC<br />

1978wHI<br />

1976CHA<br />

1976wHI<br />

1947CHA<br />

1978WHI<br />

1978CHA<br />

RJ45 CateGoRy 5e<br />

ComPuteR/Data SoCKet<br />

1976WHI<br />

1976CHA<br />

RJ45/euRo outlet<br />

two moDule unSeRViCeD<br />

1947WHI<br />

1947CHA<br />

RJ45/lJu6C outlet<br />

two moDule, unSeRViCeD<br />

1978 Data socket to<br />

Category 5e.<br />

k1976 euro 50x50mm<br />

(accommodates 2 outlets).<br />

k1947 Cut out dimensions lJu6C<br />

22x37mm for each outlet.<br />

1985WHI<br />

1985CHA<br />

BnC tyPe<br />

1985wHI<br />

1985CHA<br />

Supplied complete with enclosure<br />

box together with all necessary<br />

fixing screws for mounting on to<br />

the trunking.<br />

Crimped connections.<br />

impedance 50Ω.<br />

eLv<br />

Blank Plates<br />

1986wHI<br />

1986CHA<br />

1986WHI<br />

1986CHA<br />

elV Box anD CoVeR<br />

Can be punched for use with any<br />

elV accessory that can be mounted<br />

over the busbars.<br />

Supplied complete with enclosure<br />

box together with fixing screws for<br />

mounting on to the trunking.<br />

Data outlets<br />

FOR ExTENSION<br />

TRUNKING<br />

RJ45 BNC<br />

K1941wHI<br />

K1941CHA<br />

K1977wHI<br />

K1977CHA<br />

K1941WHI<br />

K1941CHA<br />

RJ45/lJu6C<br />

telePHone/Data outlet<br />

(unSeRViCeD) two moDule<br />

K1977WHI<br />

K1977CHA<br />

RJ45/euRo<br />

telePHone/Data outlet<br />

(unSeRViCeD) two moDule<br />

Plates for mounting clip in RJ45/<br />

lJu6C and RJ45/euro data modules.<br />

accessory modules not supplied.<br />

Cut out DimenSionS:<br />

k1941 22mm x 37mm for<br />

each outlet.<br />

k1977 50x50mm which<br />

accommodates 2 outlets.<br />

K1989WHI<br />

K1989CHA<br />

BnC tyPe<br />

K1989wHI<br />

K1989CHA<br />

Crimped connections.<br />

impedance 50Ω.Ω


<strong>Powerlink</strong> <strong>Plus</strong><br />

technical hotline +44 (0)1268 563720 perimeter and distribution | cable management<br />

eLv<br />

Blank Plates<br />

FOR ExTENSION<br />

TRUNKING<br />

K1987WHI<br />

K1987CHA<br />

elV CoVeR<br />

K1987wHI<br />

K1987CHA<br />

Can be punched to accommodate<br />

elV outlets.<br />

Flush<br />

Accessory<br />

Mounting<br />

Frames<br />

1928<br />

1946wHI<br />

1998<br />

12024SLT9<br />

1928<br />

1 GanG aCCeSSoRy<br />

mountinG Kit witH<br />

BuSBaR SHielD<br />

1946WHI<br />

2 GanG aCCeSSoRy<br />

mountinG Kit<br />

witH FRame anD PattReSS<br />

1998<br />

1 GanG mountinG<br />

FRame & Box FoR elV aCCeSSoRieS<br />

12024SLT9<br />

mountinG FRame FoR<br />

2 GanG aCCeSSoRy<br />

1928 For fixing standard single<br />

gang accessories to the trunking.<br />

the accessories can be connected<br />

to the busbars by using one of the<br />

cable termination components or<br />

wired separately. Complete with<br />

fixing screws.<br />

1946 For fixing Sentrysockets,<br />

Filtered sockets and two gang<br />

accessories to the trunking.<br />

Supplied with busbar terminations<br />

and cover, mounting frame and<br />

extension pattress together with<br />

fixing screws.<br />

1998 For fixing standard single<br />

gang extra low voltage outlets to<br />

the trunking. Supplied complete<br />

with enclosure box together with<br />

all the necessary fixing screws.<br />

eMC Screening<br />

Inserts<br />

vTSSx<br />

vTSSxI<br />

vTSSxE<br />

vTSSO1<br />

VTSS<br />

tRunKinG (lenGtH 3m)<br />

VTSSI<br />

inteRnal CoRneR<br />

VTSSE<br />

exteRnal CoRneR<br />

21016SST9<br />

SPaRe BonDinG linKS<br />

VTSSO1<br />

outlet Box aSSemBly<br />

VTSSx<br />

extenSion tRunKinG<br />

3 metRe lenGtH<br />

VTSSxI<br />

inteRnal CoRneR FoR<br />

extenSion tRunKinG<br />

VTSSxE<br />

exteRnal CoRneR FoR<br />

extenSion tRunKinG<br />

VTSSxO1<br />

outlet Box aSSemBly<br />

FoR extenSion tRunKinG<br />

Screening inserts can be used as<br />

a screen for computer services cables.<br />

not for use with power cables.<br />

lengths include earth lead and fixing<br />

screws.<br />

VtSS fits top and bottom data<br />

compartments only.<br />

Box not supplied.<br />

Trunking<br />

Accessories<br />

and<br />

Plug in Cable<br />

Terminations<br />

(3 Pole)<br />

K1925wHI<br />

1919<br />

K1937CHA 1923wHI<br />

1924wHI<br />

K1925WHI<br />

PluG in BuSBaR CouPleR<br />

1919<br />

CaBle linK aSSemBly<br />

K1937CHA<br />

CaBle CRoSSinG BaRRieR<br />

1923WHI<br />

10mm 2 CaBle teRmination<br />

1924WHI<br />

25mm 2 CaBle teRmination<br />

K1925 to connect lengths of individual<br />

busbars together. Rating 63a.<br />

1919 Prewired corner cable link for<br />

internal and external corners.<br />

Rating 63a.<br />

1937 Suitable for bridging the central<br />

compartment, where there are no<br />

busbars (Busbars are coupled by cables<br />

passing underneath).<br />

1939 to maintain segregation between<br />

the wall and the busbars or cables when<br />

installing <strong>Powerlink</strong> around a pillar of less<br />

than 125mm.<br />

1923 to connect the busbar to the<br />

mains supply or to electrical accessories<br />

mounted onto mounting frames.<br />

Rating: 50a.<br />

1924 to connect the busbars to the<br />

mains supply and for connecting the<br />

busbars around corners (two required).<br />

Rating: 63a.<br />

Trunking<br />

Components<br />

and Spares<br />

1909<br />

CHA<br />

1930<br />

wHI<br />

1909WHI<br />

1909CHA<br />

CentRal CoVeR CouPleR<br />

1930WHI<br />

aCCeSSoRy SPaCeR<br />

1909<br />

wHI<br />

1933wHI<br />

343<br />

1933WHI<br />

BuSBaR SeCtion<br />

for dado trunking without busbars.<br />

Supplied in 3m lengths.<br />

11750PST9<br />

CoVeR SCRewS<br />

11816PS<br />

aCCeSSoRy SCRewS<br />

11817PS<br />

CaBle teRmination<br />

& BuSBaR CoVeR SCRewS<br />

11827PS<br />

FixinG SCRew BuSHeS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!