04.02.2013 Views

Removing water at this point, using a system - JCM

Removing water at this point, using a system - JCM

Removing water at this point, using a system - JCM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RICOR<br />

Cryogenic & Vacuum Systems<br />

Introducing a Unique Altern<strong>at</strong>ive to Cryo Pumping<br />

MicroStar TM<br />

a self-contained cryogenic <strong>w<strong>at</strong>er</strong> vapor pump<br />

Fe<strong>at</strong>ures Benefits<br />

No external compressor or gas lines Compact-Easy install<strong>at</strong>ion and saving<br />

on footprint<br />

P<strong>at</strong>ented fast regener<strong>at</strong>ion-No need<br />

for he<strong>at</strong>ers<br />

Simple and safe <strong>system</strong> (fire and combustion<br />

hazard free)<br />

MTBF>30,000 HRS Simple and “bullet proof” cryo mechanism<br />

Cooler is controlled by a simple easy to<br />

use temper<strong>at</strong>ure controller<br />

Unique Stirling cryo cooler to chill the<br />

cryogenic panel<br />

• Base temp is user adjustable and can be<br />

altered “on the fly”<br />

• Temp stability can be set to a level<br />

of ±0.2 Kelvin<br />

Stirling-The most production worthy efficient<br />

cooling cycle-low input power<br />

Maintenance Free Low cost of ownership<br />

Controller includes RS-232 and discrete<br />

signals outputs<br />

Easy and simple pump to tool integr<strong>at</strong>ion<br />

General<br />

The MicroStar is a st<strong>at</strong>e-of-the-art, completely self-contained,<br />

compact cryogenic <strong>w<strong>at</strong>er</strong> vapor pump. Unlike conventional<br />

<strong>system</strong>s, it does not require a separ<strong>at</strong>e helium compressor and<br />

gas lines.<br />

This enables fast, simple and painless pump to tool integr<strong>at</strong>ion,<br />

<strong>at</strong> the lowest possible cost.<br />

Fe<strong>at</strong>ures<br />

New Approach To Cryo-Pumping<br />

The MicroStar combined with turbo pump (TMP-mechanical or<br />

magnetic levit<strong>at</strong>ed bearings) addresses some of the main flaws<br />

th<strong>at</strong> exist with traditional Cryo pumping.<br />

A TurboStar – combin<strong>at</strong>ion of TMP and MicroStar – offers<br />

reduced partial pressure of <strong>w<strong>at</strong>er</strong> and total base pressure<br />

together with saving up to 50% of the pump down time.<br />

Cryo Pump TurboStar<br />

High W<strong>at</strong>er Vapor Pumping Speed Good Good<br />

Regener<strong>at</strong>ion Often Rarely<br />

Self contained-On the tool<br />

pumping setup<br />

Ability to pump toxic, corrosive<br />

explosive gasses<br />

No Yes<br />

No,<br />

Hazardous!<br />

Yes<br />

Ability to withstand hi flow processes Problem<strong>at</strong>ic Good<br />

Sub Fab space Required Not required<br />

Constant permanent gasses speed Poor Good<br />

The MicroStar can be utilized as an upgrade to an existing pump<br />

(mechanical or TMP) on load lock, or transfer or, and process<br />

chambers. On process chambers, a set of 8” MicroStar and 4”<br />

turbo-pump can often replace the traditional Cryo pump and<br />

therefore elimin<strong>at</strong>e regener<strong>at</strong>ion while providing MicroStar‘s<br />

high <strong>w<strong>at</strong>er</strong> vapor pumping speed and the turbo constant<br />

permanent gases speed.<br />

Load locks present the gre<strong>at</strong>est risk of introducing <strong>w<strong>at</strong>er</strong> into<br />

the chamber <strong>system</strong>. W<strong>at</strong>er vapor can react with process gasses<br />

producing particul<strong>at</strong>e or corrosive by-products reducing yields<br />

and damaging chamber components.<br />

<strong>Removing</strong> <strong>w<strong>at</strong>er</strong> <strong>at</strong> <strong>this</strong> <strong>point</strong>, <strong>using</strong> a <strong>system</strong> containing the<br />

MicroStar W<strong>at</strong>er Vapor Pump can:<br />

• Provide favorable, consistent process conditions<br />

• Reduce the risk of corrosive by-products<br />

• Reduce the pump down time by up to 50%This can mean<br />

higher uptime and improved productivity<br />

Standard Vacuum Flange<br />

The MicroStar is available in all standard vacuum flanges types.<br />

It is also available without a flange for non-standard in situ<br />

applic<strong>at</strong>ions.<br />

High Speed W<strong>at</strong>er Pumping<br />

The cold panel is kept <strong>at</strong> 110K to 140K. At <strong>this</strong> temper<strong>at</strong>ure<br />

only <strong>w<strong>at</strong>er</strong> molecules are captured to a partial pressure as low as<br />

below 10-10 Torr. The temper<strong>at</strong>ure is user defined and could be<br />

set to a lower base temp in order to pump other condensable<br />

gasses.<br />

Permanent gasses conductance is maximized thanks to<br />

optimized geometric design.<br />

Unique, Fast & Safe Regener<strong>at</strong>ion<br />

In a unique p<strong>at</strong>ented process, the frequency of the Stirling<br />

engine is altered ca<strong>using</strong> the thermodynamics of the <strong>system</strong><br />

to change from cooling to he<strong>at</strong>ing. No other he<strong>at</strong> source is<br />

required to achieve full regener<strong>at</strong>ion cycle in less than 40<br />

minutes. As only <strong>w<strong>at</strong>er</strong> vapor is captured on the cold panel,<br />

the regener<strong>at</strong>ion process does not release hazardous gasses in<br />

dangerous concentr<strong>at</strong>ions into the vacuum <strong>system</strong>. For extreme<br />

cases where regener<strong>at</strong>ion fast cycle is a requirement, he<strong>at</strong>ers<br />

can be added to expedite the cycle.<br />

Ultra Low Vibr<strong>at</strong>ions Cooler Option<br />

An ultra low vibr<strong>at</strong>ion version of the pump is available for<br />

very sensitive applic<strong>at</strong>ions. These may be detector cooling<br />

applic<strong>at</strong>ions or other processes in which prior to MicroStar LN2<br />

was the only available cooling option.


➤<br />

Microstar In Line<br />

Example of Microstar<br />

connected to Turbo<br />

Pump<br />

➤<br />

In Situ Ready to<br />

Incorpor<strong>at</strong>e any<br />

Cryo Panel Design<br />

Example of Load lock<br />

Typical Install<strong>at</strong>ion<br />

➤<br />

In Situ Forced Air<br />

Cooled DN40CF<br />

Interface Flange<br />

Example of<br />

Microstar InSitu<br />

Typical Install<strong>at</strong>ion<br />

➤<br />

In Situ Version with<br />

special Cryo Panel<br />

VACUUM SHROUD<br />

CRYOPANEL<br />

66 FROM FLANGE<br />

SEALING SURFACE<br />

TO COLD HEAD END<br />

65<br />

A-A (1:4)<br />

139<br />

92<br />

FLOW<br />

104<br />

Microstar In Line Type Outline Dimensions (mm)<br />

(See details on ordering info. table)<br />

C<br />

NW40 CLAMP<br />

O-RING SEALING<br />

H<br />

WATER INLET<br />

by 6mm plastic pipe,<br />

straight push-on<br />

connector<br />

Top View<br />

NW40 FLANGE<br />

M5 MTD 5<br />

169<br />

4x<br />

M5 MTD 5<br />

ON 26 B.C<br />

C<br />

B<br />

Ø 101<br />

AIR FLOW<br />

- + CONTROLLER CONTROLLER<br />

Ø 55<br />

NW40<br />

FLANGE<br />

39<br />

ֿ147 ֿ<br />

19.5<br />

66<br />

39<br />

ֿ101 ֿ<br />

COOLER CABLE<br />

A1 B1 A2<br />

B2<br />

Microstar In Situ Type Outline Dimensions (mm)<br />

B<br />

245<br />

426<br />

43.7<br />

82<br />

Ø 70<br />

DN40CF<br />

FLANGE<br />

33<br />

321<br />

A<br />

282<br />

CRYOPANEL DIAMETER<br />

SHROUD O.D.<br />

SHROUD I.D.<br />

5xM5<br />

TEMP. DIODE<br />

129<br />

151<br />

A<br />

TRASPORTATION<br />

PROTECTIVE<br />

COVER<br />

Top View<br />

DN40CF FLANGE<br />

M5 MTD 5<br />

4x<br />

M5 MTD 5<br />

ON ֿ26 ֿ B.C<br />

6x<br />

M6 MTD 8<br />

ON 58.7 B.C


➤<br />

Adding Microstar<br />

decreases Pump down<br />

time from 90 to less<br />

than 20 minutes<br />

➤<br />

➤<br />

MicroStar 160 & 4"<br />

4" Turbo<br />

6" Turbo<br />

Maximum<br />

Performance<br />

Ordering<br />

Inform<strong>at</strong>ion<br />

Scope of Supply<br />

Pressure (Torr)<br />

1.00E-03<br />

1.00E-04<br />

1.00E-05<br />

1.00E-06<br />

1.00E-07<br />

1.00E-08<br />

Time (Min)<br />

ORDERING<br />

P/N TYPE<br />

VACUUM SHROUD<br />

O.D. I.D.<br />

B53401000 In-Situ Pump KF-40 Interface Flange<br />

50 100 150<br />

CRYOPANEL<br />

DIAMETER H B*<br />

B53401200 ISO100 130 103 93 303 ISO Claw Flanges<br />

B53401300 ISO160 180 153 130 323 ISO Claw Flanges<br />

B53401400 ISO200 240 213 190 355 ISO Claw Flanges<br />

B53401800 ISO250 290 261 236 383.3 ISO Claw Flanges<br />

C*<br />

No. and size<br />

of bores<br />

B53401500 DN100CF 152 102 93 302 130.2 15 x Ø8.4<br />

B53401600 DN160CF 202 153 130 323 181 19 x Ø8.4<br />

B53401700 DN200CF 254 206 190 355 231.8 23 x Ø8.4<br />

B53401450 ISO200F 285 213 190 355.5 260 12 x Ø11<br />

B53401850 ISO250F 335 261 236 383.3 310 12 x Ø11.1<br />

* for CF and ISO-F vacuum shrouds<br />

other flanges dimensions and type are available upon request<br />

PART P/N DESCRIPTION<br />

from 90 to less than 20 minutes<br />

ISO & CF 100 ISO & CF 160 ISO & CF 200<br />

W<strong>at</strong>er Vapor Pumping Speed ls -1 1,000 2,000 4,000<br />

Air (N2) Conductance Speed ls -1 700 3,500 10,000<br />

INCLUDED<br />

WITH MICROSTAR<br />

K535 PCU 235B002A Parallel control unit for K535 cooler √ ⎯<br />

Integr<strong>at</strong>ed Controller for K535 235C102A Driver/Temp controller for K535 cooler √ ⎯<br />

Power Supply Unit (PSU) 235C001A K535 52VDC, power supply unit ⎯ √<br />

Communic<strong>at</strong>ion Cable 2.9m 235R300A Communic<strong>at</strong>ion cable for Nir-Or controller √ ⎯<br />

PSU to Wall Electric Cable 2m 1P0754 IEC320 with bare ends ⎯ √<br />

PSU to Controller Cable 2.7m 235R011A PSU-Controller SDC power cable for K535 ⎯ √<br />

Customer CD 737R050A CD with LCC monitor software and user manual files √ ⎯<br />

MicroStar Cooling W<strong>at</strong>er Kit 737C010A SST coils for cooling <strong>w<strong>at</strong>er</strong> √ ⎯<br />

INCLUDED<br />

WITH PSU<br />

DOC00610/A1<br />

➤<br />

MicroStar General<br />

Technical D<strong>at</strong>a<br />

➤<br />

Power Supply Unit<br />

Outline Dimensions<br />

(mm)<br />

This PSU is comp<strong>at</strong>ible<br />

for rack mount by<br />

simply dismantling<br />

the casing feet<br />

➤<br />

Power Supply Unit<br />

General Technical<br />

D<strong>at</strong>a<br />

Maximum Weight (including pump) 21 Kg (ISO250F configur<strong>at</strong>ion)<br />

Cooling Power (a) 18W@120K (23ºC ambient temper<strong>at</strong>ure)<br />

Cooling Power (b) 7W@65K (23ºC ambient temper<strong>at</strong>ure)<br />

Power Consumption 200W max. 52VDC in normal oper<strong>at</strong>ion<br />

W<strong>at</strong>er Cooling Consumption 2LPM @23ºC<br />

MTTF > 25,000 Hours<br />

Helium Gas Pressure 16 to 20 Bar<br />

Measured Noise Level 35 dB(A) from 5 meter distance<br />

Self Induced Force (vibr<strong>at</strong>ion) 20 Nrms <strong>at</strong> expander axis<br />

101.5<br />

100-240 VAC INLET<br />

IEC320 + FUSE<br />

52 VDC OUTLET<br />

LOCKING 3 POLES<br />

80mm COOLING FAN<br />

335.8<br />

��������� ����������<br />

130 (3U)<br />

A<br />

A<br />

141 (28HP)<br />

0<br />

1<br />

A-A<br />

CASING FEET<br />

4xØ3.5<br />

MOUNTING<br />

SCREW<br />

MAIN SWITCH<br />

OUTLET<br />

INDICATION<br />

LED<br />

ISRAEL En Harod Ihud, 18960, Israel<br />

USA Cryo-Solutions Corp.<br />

Phone. +972-4-6530800<br />

Fax. +972-4-6532424<br />

E-mail: microstar@ricor.com<br />

For more inform<strong>at</strong>ion on MicroStar visit us <strong>at</strong>: www.ricor.com or e-mail: microstar@ricor.com<br />

RICOR<br />

Cryogenic & Vacuum Systems<br />

5 Nrms <strong>at</strong> motor axis<br />

Oper<strong>at</strong>ing Temper<strong>at</strong>ure 0 to +50°C (cooler body temper<strong>at</strong>ure)<br />

Storage Temper<strong>at</strong>ure -40 to +80°C (cooler body temper<strong>at</strong>ure)<br />

Humidity 10% to 90%<br />

Altitude -70 m to +3500 m rel<strong>at</strong>ive to sea level<br />

Input Voltage 100-240VAC full range<br />

Input Frequency 47-63Hz<br />

Input Current 8A <strong>at</strong> 90VAC full load<br />

Output Voltage 52 ± 2VDC<br />

Output Current 10.7A ± 5%<br />

Efficiency 70% minimum. (<strong>at</strong> 230V full load)<br />

Oper<strong>at</strong>ing Temp 0° to 50°C environment<br />

Cooling Air-Cooled<br />

Weight Maximum 2.6Kg<br />

Phone. +1-954-802-7477<br />

Fax. +1-954-337-2693<br />

E-mail: nirg@cryo-solutions.net<br />

Design and Production: Moshe Mirsky

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!