Lighting Control Systems Helio Lighting Management System
Lighting Control Systems Helio Lighting Management System
Lighting Control Systems Helio Lighting Management System
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Lighting</strong> <strong>Control</strong> <strong><strong>System</strong>s</strong> <strong>Helio</strong> <strong>Lighting</strong> <strong>Management</strong> <strong>System</strong><br />
LRC 5040/10 Dimensions in mm<br />
LRC 5042<br />
LRC 5048<br />
158<br />
60<br />
125<br />
220<br />
54<br />
152.6<br />
51.3<br />
175<br />
407 62<br />
LRC 5042<br />
<strong>Helio</strong> light controller with two<br />
separately controlled outputs and<br />
one interface for standard<br />
movement, light and infrared<br />
sensors.<br />
The outputs are able to switch<br />
and regulate lighting loads up to<br />
5A.The outputs and Lon bus<br />
have screw connections, the<br />
sensor interface is connected via<br />
RJ-12 plug.<br />
200<br />
LRC 5040/10<br />
<strong>Helio</strong> light controller with single<br />
channel for switching and<br />
regulating lighting loads up to 5A,<br />
and providing a sensor interface<br />
for standard IR receivers,<br />
pushbutton interface units,<br />
movement detectors, and light<br />
sensors.<br />
Type<br />
LRC5040/10<br />
Type<br />
LRC5042<br />
LRC 5048<br />
<strong>Helio</strong> light controller with eight<br />
separately controlled outputs and<br />
two interfaces for standard<br />
movement detectors, light sensors<br />
and pushbutton switches.<br />
The outputs are able to switch<br />
and regulate lighting loads upto<br />
5A.The unit has a maximum total<br />
rating of 16A. Each output has a<br />
6-pole Wieland socket (GST) that<br />
includes a maintained live for<br />
power supply to batteries in<br />
emergency luminaires.<br />
Battery performance can then be<br />
tested by interrupting the<br />
maintained power supply at<br />
prescribed intervals.<br />
Type<br />
LRC5048
<strong>Lighting</strong> <strong>Control</strong> <strong><strong>System</strong>s</strong> <strong>Helio</strong> <strong>Lighting</strong> <strong>Management</strong> <strong>System</strong><br />
LRI 5133/10<br />
Mounting plate<br />
Mounting ring<br />
LCU 5305<br />
LCU 5315<br />
47<br />
105<br />
105<br />
∅ 75<br />
∅ 113<br />
∅ 99<br />
∅ 116<br />
∅ 95<br />
Dimensions in mm<br />
60<br />
60<br />
30<br />
60<br />
90<br />
90<br />
6 52<br />
LRI 5133/10<br />
<strong>Helio</strong> multi-sensor with movement<br />
detector, light sensor, and infrared<br />
receiver used for remote and<br />
automatic control of lighting,<br />
HVAC and sun blind functions in<br />
integrated room control<br />
applications.The IR receiver can be<br />
combined with hand-held and wall<br />
transmitters for remote control<br />
operations and with wall<br />
transmitters with built-in<br />
Mounting plate for surface<br />
mounting of LRI 5133.<br />
This plate is packed together with<br />
the sensor itself.<br />
Mounting ring for recessed<br />
mounting of LRI 5133.<br />
This ring is packed together with<br />
the sensor itself.<br />
temperature sensors for automatic<br />
temperature control.<br />
Units are connected directly to a<br />
LonWorks ® bus cable for network<br />
communication and power supply.<br />
Their functional behaviour can be<br />
adapted by downloading project<br />
specific software over the bus.<br />
Type<br />
LRI5133/10<br />
LCU 5305<br />
<strong>Helio</strong> digital I/O module providing<br />
a simple dry contact interface to<br />
and from various systems.<br />
The unit has 2 inputs and 2<br />
outputs.<br />
Type<br />
LCU5305<br />
LCU 5315<br />
<strong>Helio</strong> system clock providing a<br />
programmable switching schedule.<br />
Type<br />
LCU5315
<strong>Lighting</strong> <strong>Control</strong> <strong><strong>System</strong>s</strong> <strong>Helio</strong> <strong>Lighting</strong> <strong>Management</strong> <strong>System</strong><br />
LCN 5225<br />
LCN 5235<br />
LCN 5245<br />
Unilon software<br />
Unilon is a general configuration<br />
tool for LonWorks ® based<br />
systems. It offers a fully graphical<br />
user interface and many other<br />
features for commissioning of<br />
LonWorks ® systems. Plug-ins for<br />
the <strong>Helio</strong> controllers are<br />
separately available. Each actual<br />
214<br />
214<br />
Dimensions in mm<br />
The <strong>Helio</strong> system is completed with a selection of the following General Purpose Components.<br />
Infrared transmitters<br />
IRC 2130<br />
IRT 8050<br />
IRT 8065<br />
IRT 8070<br />
Sensors<br />
IRR 8124<br />
IRR 8125<br />
LRL 8101<br />
LRM 8112<br />
LRM 8115<br />
LRI 8133<br />
214<br />
installation of one node in a<br />
network requires a license, socalled<br />
credit key. Unilon, the<br />
<strong>Helio</strong> plug-ins and the credit<br />
keys can be ordered in many<br />
variations and combinations.<br />
Contact your local Philips<br />
<strong>Lighting</strong> <strong>Control</strong>s representative<br />
for more information.<br />
50<br />
60<br />
50<br />
60<br />
50<br />
60<br />
29<br />
29<br />
29<br />
90<br />
90<br />
90<br />
A fully functional demo and<br />
training versions are available.<br />
With the training version, it is<br />
possible to install up to 32 nodes<br />
for training or demonstration<br />
purposes. Both versions are<br />
delivered with all available <strong>Helio</strong><br />
plug-ins. Contact your local Philips<br />
<strong>Lighting</strong> <strong>Control</strong>s representative<br />
for more information.<br />
Push-button interface<br />
LCU 8020<br />
Dimmers<br />
LRD 8000<br />
LRD 8010<br />
Cables<br />
LCC 8011<br />
LCC 8012<br />
LCC 8013<br />
LCC 8014<br />
LCC 8024<br />
LCC 5301<br />
LCN 5225<br />
<strong>Helio</strong> bus power supply unit<br />
providing a voltage of 42 V DC<br />
and a current of 1.4 A to the<br />
linkpower bus.<br />
The bus voltage and current is<br />
used by devices not connected to<br />
the mains or auxiliary power<br />
supplies - <strong>Helio</strong> sensors, system<br />
clocks and digital I/Os.<br />
Type<br />
LCN5225<br />
LCN 5235<br />
<strong>Helio</strong> bus power supply/repeater<br />
regenerating bus communication<br />
and providing power to the bus.<br />
Type<br />
LCN5235<br />
LCN 5245<br />
<strong>Helio</strong> bus power supply/router<br />
repeater regenerating and<br />
managing bus communication and<br />
providing power to the bus.<br />
Type<br />
LCN5245<br />
Handbooks<br />
For both Unilon and <strong>Helio</strong><br />
handbooks are available. Contact<br />
your local Philips <strong>Lighting</strong><br />
<strong>Control</strong>s representative for more<br />
information and for availability in<br />
your language