GIESSE <strong>OS</strong> OPERATOR<br />

Technical details<br />

System Design for <strong>the</strong> <strong>OS</strong><br />

<strong>Operator</strong><br />

The <strong>OS</strong> <strong>Operator</strong> has been designed to<br />

work with a vent-to-frame clearances<br />

that allow for standard four bar hinges.<br />

The ideal design utilizes an integral<br />

groove on <strong>the</strong> vent with a flat surface on<br />

<strong>the</strong> frame.<br />

For a detailed review of potential applications,<br />

please contact <strong>Giesse</strong> Engineering<br />

for assistance.<br />

Size Limitations<br />

Overall size restrictions for windows utilizing<br />

<strong>the</strong> <strong>OS</strong> <strong>Operator</strong> depend upon<br />

many factors including <strong>the</strong> hinges utilized,<br />

glass size, windload requirements,<br />

and impact requirements.<br />

Max and Min vent size<br />

<strong>OS</strong> <strong>Operator</strong> mechanism 725<br />

Code 02000 000<br />

<strong>OS</strong> <strong>Operator</strong> mechanism 466,5<br />

Code 02002 000 1<br />

Code 02002 000 2<br />

Test Results<br />

The <strong>OS</strong> <strong>Operator</strong> has passed cycle testing<br />

at 15,000 cycles for both an awning<br />

and casement windows at AAMA’s<br />

gateway sizes.<br />

In addition, <strong>the</strong> use of a single cremone<br />

handle in <strong>the</strong> <strong>OS</strong> <strong>Operator</strong> substantially<br />

improves air and water performance.<br />

Traditional systems with rotary<br />

operators and multiple locks – penetrate<br />

<strong>the</strong> frame with more and larger<br />

openings. Systems designed with <strong>the</strong><br />

<strong>OS</strong> <strong>Operator</strong> can result in reduced air<br />

infiltration and higher water performance<br />

than <strong>the</strong>se traditional systems.<br />

1,6<br />

+0,1<br />

0<br />

0<br />

3 -0,1<br />

L Max.<br />

L Min.<br />

0<br />

-0,2<br />

16,5 ÷ 18<br />

+0,2<br />

-0,1<br />

1,8<br />

15<br />

+0,2<br />

-0,1<br />

20<br />

0<br />

4,5 -0,1<br />

+0,1<br />

3 0<br />

15 ÷ 18,5<br />

6<br />

83/128" ÷ 181/256"<br />

1/16"<br />

15/128"<br />

+ 1/256"<br />

0<br />

0<br />

- 1/256"<br />

Top hung durability test Test mechanism<br />

"<br />

9/128 0 - 1/128"<br />

+ 1/128"<br />

- 1/256"<br />

151/256"<br />

[mm] [inches]<br />

Top Hung Side Hung<br />

L<br />

H<br />

45/256"<br />

15/128"<br />

151/256" ÷ 93/128"<br />

+ 1/128"<br />

- 1/256"<br />

101/128"<br />

0<br />

- 1/256"<br />

+ 1/256"<br />

0<br />

1500 mm 2000 mm 900 mm 1600 mm<br />

H Max.<br />

L Max.<br />

H Max.<br />

59 1/16" 78 3/4" 35 7/16" 63"<br />

800 mm 450 mm * 450 mm* 800 mm<br />

31 1/2"<br />

H Min.<br />

17 22/32"<br />

L Min.<br />

17 23/32"<br />

H Min.<br />

31 1/2"<br />

1500 mm 2000 mm 900 mm 1600 mm<br />

L Max. H Max. L Max. H Max.<br />

59 1/16" 78 3/4" 35 7/16" 63"<br />

500 mm 450 mm * 450 mm* 500 mm<br />

L Min. H Min. L Min. H Min.<br />

19 11/16" 17 22/32" 17 23/32" 19 11/16"<br />

* IF THIS DIMENSION IS