Flow (horizontal) Flow (vertical)<br />

from left to right from top to bottom<br />

E = Oil filler neck O = Oil-level gauge glass<br />

A = Oil drain sleeve V = Screw plug<br />

9. Commissioning<br />

© Elster GmbH · All rights reserved · Subject to technical modification<br />

Elster-Instromet<br />

Figure 8: Horizontal and vertical installation positions, oil filling and oil-level display for Type<br />

<strong>RVG</strong>-ST<br />

Flow direction Oil-level gauge glass Oil quantity<br />

Horizontal<br />

Vertical<br />

Oil level<br />

On the front side<br />

of the meter<br />

On the side<br />

of the housing cover<br />

Oil level<br />

Approx. 25 ml<br />

Approx. 80 ml<br />

Table 4: Guide values for oil quantity on commissioning and for oil changes for Type<br />

<strong>RVG</strong>-ST<br />

In order not to damage the meter,<br />

– slowly fill the system until operating pressure is reached.<br />

– The pressure rise may not exceed 350 mbar/s. You should use a bypass line for filling<br />

(recommendation: 12 mm pipe diameter).<br />

– Do no exceed the measuring range even briefly!<br />

– Conduct a tightness test!<br />

Attention: you must please note the instructions in Section 5, „Operating Location“.<br />