Troubleshooting<br />
Always remove the battery before carrying out any work on the power tool.<br />
Condition Cause Remedy<br />
Machine does not run when switched on<br />
<strong>RMA</strong> <strong>370</strong><br />
No electrical contact between power tool<br />
and battery<br />
Battery discharged<br />
(1 light emitting diode on battery flashes<br />
green)<br />
Battery too hot / too cold<br />
(1 light emitting diode on battery glows<br />
red)<br />
Fault in battery<br />
(4 light emitting diodes on battery flash<br />
red)<br />
English<br />
Remove battery, check contacts and refit<br />
battery<br />
Charge the battery<br />
Allow battery to cool down / at temperatures<br />
of about 59°F - 68°F (15°C - 20°C),<br />
allow battery to warm up slowly<br />
Take the battery out of the power tool<br />
and refit it. Switch on the power tool – if<br />
the light emitting diodes still flash, the<br />
battery is faulty and must be replaced.<br />
Fuse key not fitted Fit the fuse key<br />
Fault in fuse key Replace fuse key<br />
Power tool too hot<br />
Allow power tool to cool down<br />
(3 light emitting diodes on battery glow<br />
red)<br />
Electromagnetic interference or fault in<br />
power tool<br />
(3 light emitting diodes on battery flash<br />
red)<br />
Take the battery out of the power tool<br />
and refit it. Switch on the power tool – if<br />
the light emitting diodes still flash, the<br />
power tool is faulty and must be checked<br />
by a servicing dealer 1) .<br />
Motor overloaded by high or damp grass Do not start motor in high grass, adjust<br />
cutting height to suit conditions<br />
Mower housing blocked Clean mower housing<br />
Moisture in power tool and/or battery Allow power tool/battery to dry<br />