USER INSTRUCTIONS<br />

ELECTRONIC WATER HEATERS (WITHOUT PERMANENT PILOT LIGHT)<br />

- Prior checks<br />

1. Make sure hot water taps are turned off.<br />

2. Turn on the gas to water heater stopcock that is located where gas is supplied to the appliance.<br />

3. Check that the 1.5 V batteries are correctly installed according to polarity (+ and -) and the safety seal has<br />

been removed.<br />

4. Check that they are sufficiently charged for the water heater to function.<br />

- Manual selection of Burner Power<br />

To ignite the appliance, turn the gas knob from the position to one of the 2 minimum<br />

or maximum positions.<br />

The gas knob allows you to select the water heater power, minimum ( ) or maximum<br />

( ), and intermediate positions according to the hot water intensity required. Turn the gas<br />

knob to the position (large flame), the unit heats the water at<br />

full power. If the temperature is too high, for example in summer or when small volumes of not<br />

very hot water are required, turn the knob to the right to position (small flame), reducing<br />

the power (and gas consumption) almost by half.<br />

- Temperature selection<br />

With the Temperature Selector you can easily gauge the water temperature by turning the selector to the<br />

right to achieve a higher temperature, or to the left to obtain less hot water.<br />

- Hot Water Service<br />

- Once the previous settings have been selected, the water heater will start the process; turning on the hot<br />

water tap will automatically generate continuous sparks through its ignition electrode and directly light the<br />

burner.<br />

- All the electronic models have an ionisation probe, which is immersed in the flame to<br />

control it.<br />

- If for any reason an issue has occurred in the gas circuit and the probe does not detect the<br />

flame’s presence, the ignition electrode will automatically generate sparks for a few seconds to<br />

ignite the burner; in the event that the water heater does not turn on, it will be out of service.<br />

- You must remove the cause or element that prevents the gas from reaching the water heater,<br />

for example if the stopcock has been inadvertently turned off, worn out gas cylinder, etc.<br />