USER INSTRUCTIONS<br />
ELECTRONIC WATER HEATERS (WITHOUT PERMANENT PILOT LIGHT)<br />
- Prior checks<br />
1. Make sure hot water taps are turned off.<br />
2. Turn on the gas to water heater stopcock that is located where gas is supplied to the appliance.<br />
3. Check that the 1.5 V batteries are correctly installed according to polarity (+ and -) and the safety seal has<br />
been removed.<br />
4. Check that they are sufficiently charged for the water heater to function.<br />
- Manual selection of Burner Power<br />
To ignite the appliance, turn the gas knob from the position to one of the 2 minimum<br />
or maximum positions.<br />
The gas knob allows you to select the water heater power, minimum ( ) or maximum<br />
( ), and intermediate positions according to the hot water intensity required. Turn the gas<br />
knob to the position (large flame), the unit heats the water at<br />
full power. If the temperature is too high, for example in summer or when small volumes of not<br />
very hot water are required, turn the knob to the right to position (small flame), reducing<br />
the power (and gas consumption) almost by half.<br />
- Temperature selection<br />
With the Temperature Selector you can easily gauge the water temperature by turning the selector to the<br />
right to achieve a higher temperature, or to the left to obtain less hot water.<br />
- Hot Water Service<br />
- Once the previous settings have been selected, the water heater will start the process; turning on the hot<br />
water tap will automatically generate continuous sparks through its ignition electrode and directly light the<br />
burner.<br />
- All the electronic models have an ionisation probe, which is immersed in the flame to<br />
control it.<br />
- If for any reason an issue has occurred in the gas circuit and the probe does not detect the<br />
flame’s presence, the ignition electrode will automatically generate sparks for a few seconds to<br />
ignite the burner; in the event that the water heater does not turn on, it will be out of service.<br />
- You must remove the cause or element that prevents the gas from reaching the water heater,<br />
for example if the stopcock has been inadvertently turned off, worn out gas cylinder, etc.<br />