25.10.2013 Views

ADVANCE - Gaswinkel

ADVANCE - Gaswinkel

ADVANCE - Gaswinkel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TECHNICAL SPECIFICATIONS<br />

5 LITRES 10 LITRES<br />

TECHNICAL SPECIFICATIONS CMB-5 CMB-5 E EB-10 EB-10 E<br />

CATEGORY BUTANE / PROPANE II2H3+ II2H3+ II2H3+ II2H3+<br />

NATURAL GAS II2H3+ II2H3+ II2H3+ II2H3+<br />

APPLIANCE TYPE B 11BS B 11 B 11BS B 11<br />

TYPE OF INSTALLATION Inside Outside Inside Outside<br />

NOMINAL CONSUMPTION - kW 10.1 10.1 20.2 20.2<br />

USEFUL POWER - kW<br />

WATER (l/min) AND<br />

TEMPERATURE RATE: (a)<br />

40º C (∆= 25° C)<br />

65º C (∆= 50° C)<br />

minimum<br />

maximum<br />

MINIMUM WATER PRESSURE (bar)<br />

FOR TEMPERATURE: (b)<br />

40º C (∆= 25° C)<br />

65º C (∆= 50° C)<br />

8.9 8.9 17.8 17.8<br />

MAXIMUM WATER PRESSURE (bar) (d) 10 10 10 10<br />

—<br />

5.1<br />

—<br />

2.6<br />

—<br />

0.5<br />

—<br />

0.2<br />

GAS CONSUMPTION (1013 mbar/288° K) (c)<br />

0.32<br />

Propane G-31<br />

kg/h<br />

0.79<br />

Butane G-30<br />

Natural gas G-20 m3 /h<br />

0.43<br />

1.07<br />

GAS PRESSURE (mbar)<br />

At the heater inlet (mbar) Butane G-<br />

30<br />

Propane G-31<br />

Natural G-20<br />

In the burner- Maximum<br />

Power ( ) (mbar)<br />

Butane G-30<br />

Propane G-31<br />

Natural G-20<br />

In the burner- Minimum<br />

power ( ) (mbar)<br />

Butane G-30<br />

Propane G-31<br />

Natural G-20<br />

28-30<br />

37<br />

20<br />

27.3<br />

35.3<br />

14.7<br />

—<br />

—<br />

—<br />

12<br />

—<br />

5.1<br />

—<br />

2.6<br />

—<br />

0.5<br />

—<br />

0.2<br />

0.32<br />

0.79<br />

0.43<br />

1.07<br />

28-30<br />

37<br />

20<br />

27.3<br />

35.3<br />

14.7<br />

—<br />

—<br />

—<br />

—<br />

10.1<br />

—<br />

5.1<br />

—<br />

0.5<br />

—<br />

0.2<br />

0.63<br />

1.58<br />

0.86<br />

2.14<br />

28-30<br />

37<br />

20<br />

27.57<br />

35.84<br />

13.33<br />

ELECTRICAL CURRENT (220V—50 Hz) no no no no<br />

—<br />

—<br />

—<br />

—<br />

10.1<br />

—<br />

5.1<br />

—<br />

0.5<br />

—<br />

0.2<br />

0.63<br />

1.58<br />

0.86<br />

2.14<br />

28-30<br />

37<br />

20<br />

27.57<br />

35.84<br />

13.33<br />

“EC” MARK 0461BT0927 0461BT0927 0461BT0927 0461BT0927<br />

(a) Based on input temperature of cold water at 15º C.<br />

(b) This is the pressure required to operate the appliance, allowing for the addition of what is needed based on diameters and length of the pipeline<br />

circuit used.<br />

(c) This consumption is produced in reference conditions for an 84% yield of the IPC<br />

(d) Maximum pressure with water temperature of 75º C.<br />

—<br />

—<br />

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!