• Sequence of OperationThe Model DCEZ-60 is made up of a series of accumulationzones, each zone having an EZLogic® accumulation kit,and an accumulation lift module to lift the load up off theconstantly moving drag chain. The sequence of "loading"and "unloading" the conveyor is as follows:LOADING THE CONVEYOR (Figure 12A)1. . .2. . .3. . .4. . .Beginning with the conveyor "empty," and the zone stopsignal to the discharge zone controller "active," a loadplaced on the conveyor continues forward until it reachesthe discharge zone (Zone #1).If two or more loads are placed on the conveyor with aspace of less than one zone length between them, theloads will singulate (separate) during the first few feet oftravel on the conveyor, until a space approximately equalto one zone length exists between all loads.When load #1 activates controller "A", Zone #1 stopsdriving. A signal is sent to Zone #2 indicating that Zone#1 is occupied (Figure 12A).When load #2 activates controller "B", Zone #2 stopsdriving. A signal is sent to Zone #3 indicating that Zone#2 is occupied.The above sequences are repeated until the conveyor isfully loaded.UNLOADING THE CONVEYOR1. . .2. . .3. . .Releasing load #1 is accomplished by "de-activating" thezone stop signal to the discharge zone (Refer to the"Auxiliary Connections" section on page 13). Thiscauses the lift module to move the load back down ontothe chain in Zone #1. Load #1 will then move forward,causing a gap between itself and load #2 (Figure 12B).When load #1 clears controller "A", load #2 will then moveforward, creating a gap between itself and load #3.This sequence will continue as long as the precedingload continues to move forward.FIGURE 12A• Secuencia de OperaciónEl modelo DCEZ-60 está compuesto por una serie de zonas deacumulación. Cada zona posee un módulo de acumulaciónEZLogic®, y un módulo levantador de acumulación que levantala carga de la cadena de arrastre que se encuentraconstantemente en movimiento. La secuencia de "Carga" y"Descarga" del transportador es la siguiente:CARGANDO EL TRANSPORTADOR (Fig. 12A)1. . .2. . .3. . .4. . .Empezando con el transportador "vacío" y la señal deparo de zona “activa" en la zona de descarga, una cargapuesta sobre el transportador hará el recorrido hasta quellegue a la zona de descarga (Zona #1).Si dos o más cargas se colocan sobre el transportadorcon un espacio de separación entre ellas menor que lalongitud de la zona, los productos se separán durante losprimeros pies de recorrido en el transportador hasta queel espacio entre las cargas sea por lo menos igual a lalongitud de la zona.Cuando la carga #1 activa el módulo "A", la Zona #1 sedetiene completamente. Una señal es enviada a la Zona#2 indicando que la Zona #1 está ocupada (Figura 12A).Cuando la carga #2 activa el módulo "B", la Zona #2 sedetiene completamente. Una señal es enviada a la Zona#3 indicando que la Zona #2 está ocupada.La secuencia anterior se repite hasta que eltransportador quede completamente cargado.DESCARGANDO EL TRANSPORTADOR1. . .2. . .3. . .Se logra liberar la carga #1 "desactivando" la señal deparo en la zona de descarga. (Refieráse a la sección“Conexiones de Paro de Zona” en la página 13.) Estocausa que el modulo levantador mueva la carga deregreso a la cadena en la Zona #1. La carga #1 semoverá hacia adelante, causando un espacio entre símisma y la carga #2 (Figura 12B).Cuando la carga #1 despeja el módulo "A", la carga #2se moverá hacia adelante creando un espacio entre símisma y la carga #3.Esta secuencia continuará mientras las cargasprecedentes continúen moviéndose hacia adelante.FIGURE 12B12
• EZLogic ® SystemEZLogic® Accumulation System ConnectionsThe Model DCEZ-60 is equipped with the EZLogic®accumulation system. The following basic information maybe used as a guide during the installation and initial setup ofthe conveyor. For detailed information about EZLogic®system components, options, functions, and programming,please refer to the EZLogic® Component Manual.Each EZLogic® zone controller is equipped with sealedconnectors for zone-to-zone communication, solenoidoutput, and zone stop connections (figure 14A &14B).These connections are described in the following sections.ZONE CONNECTIONSEach zone has a cordset terminated with a female microconnectorand a male micro-connector. This cordsetprovides power to all the controllers on the conveyor as wellas communication between controllers (Figure. 14A).All controllers are mounted and connected at the factorywithin each conveyor section. Connections betweensections are made at installation. (See Conveyor Set-Up,page 8). The cordset from one controller is alwaysconnected to the module on the upstream side of it. This isthe way the controllers know which direction product isflowing.The cordset on the infeed end of the conveyor is simplybundled and tied in the accumulation channel and is notconnected. The infeed cordset may be replaced with aninfeed zone terminator (P/N 032.550). Protective caps areprovided to seal unused connectors.An optional conveyor-to-conveyor connector is requiredwhen two conveyors are joined end-to-end. Please refer tothe EZLogic ® Component Manual for more information.SOLENOID CONNECTIONSEach zone controller has a built-in cable to provide a zonedrive/no drive output to the solenoid air valve operating thezone. This cable is terminated with a female Pico-stylesealed snap-lock connector. Connection is made bypushing the cable connector onto the corresponding maleconnector of the valve until it snaps in.Please note that this output is only to be used to operate thezone mechanism of the conveyor. It is not to be used as anoutput signal to other control devices. If a control output isneeded, an optional auxiliary module with I/O should beused. Please refer to the EZLogic ® Component Manual formore information.AUXILIARY CONNECTIONSEvery EZLogic ® zone controller is equipped with an auxiliaryport. This connector can be used to accept either a zonestop signal, a slug input signal, or a zone wake-up signal bysimply connecting an auxiliary input cable to the auxiliaryport and then wiring the two wires of the cable to any “drycontact” type switching device, such as a toggle switch orrelay. No other components are required. The default• Sistema EZLogic ®Conexiones del Sistema de Acumulación EZLogic®El Modelo DCEZ-60 está equipado con un sistema deacumulación EZLogic®. La siguiente información básica puedeser usada como guía durante la instalación y el montaje delt r a n s p o r t a d o r. Para información más detallada sobre loscomponentes del sistema EZLogic®, sus opciones, funciones,y programación, refiérase al "EZLogic® Component Manual".Cada módulo EZLogic® está equipado con conectoressellados que permiten la comunicación zona-a-zona, consalida solenoide y con conexiones de paro de zona (Fig. 14A &14B). Estas conexiones se describen a continuación.CONEXIONES DE ZONACada zona posee un cable que termina con micro-conectormacho integrado en su interior y un cable terminado en unmicro-conector hembra. Por medio de este cable setransmite poder y comunicación entre los controladores(Fig. 14A).Todos los controladores son montados y conectados en lafábrica en cada seccion del transportador. Las conexionesentre las secciones se hacen durante la instalación (VerPágina 8). El cable de un controlador estará siempreconectado al módulo de la zona anterior para que elcontrolador sepa la dirección del flujo de los productos.El cable del controlador en la zona de carga simplementees amarrado al canal y no será conectado. El cable en lazona de carga puede ser remplazado con una terminal dealimentación (N/P 032.550). Se proporcionan terminalesprotectores para sellar los conectores que no se usarán.Cuando se unen dos transportadores, un cable conectoropcional de transportador a transportador es requerido.Refiérase al "EZLogic ® Components Manual" para mayorinformación.CONECTORES DE LA VALVULA SOLENOIDECada controlador de zona de acumulación posee un cableque provee una señal de tracción/no-tracción de la zona ala válvula solenoide de aire que la está operando.Este cable termina con un conector hembra "Pico-Style"sellado ajustable a presión. La conexión se haceenchufando el cable conector al conector macho de laválvula.Recuerde que esta señal debe ser exclusivamente utilizadapara operar el mecanismo de la zona del transportador. Nodebe ser utilizada como señal de salida de otro dispositivode control. Si una señal de control es necesaria, un móduloopcional auxiliar I/O debe ser utilizado. Refiérase al"EZLogic® Component Manual" para mayor información.CONEXIONES AUXILIARESCada controlador de zona EZLogic® está equipado conun puerto auxiliar. Este conector puede ser usado paraaceptar, ya sea una señal de paro de zona, una señal deentrada continua (slug), o una señal de activación de zona,simplemente conectando el cable de entrada auxiliar alpuerto auxiliar y después conectando los dos cables a13