4. Brief functional description<br />
The fan can be installed in four ways depending on<br />
the function as detailed below:<br />
Humidity control only, wiring diagram 1<br />
1 The fan is connected using constant phase (L) and<br />
neutral (N) for automatic humidity control.<br />
The timer can be activated manually by fitting a pull<br />
cord and pulling on this.<br />
Constant low speed + humidity control, wiring<br />
diagram 2<br />
The fan is connected using constant phase (L) and<br />
neutral (N) for automatic humidity control.<br />
Phase (L) is linked to switched live (SL) for constant<br />
low speed. When humid air is present the fan runs<br />
in the selected mode of silent or maximum. Once<br />
the humid air has been expelled, the fan returns to<br />
running at low speed. You can adjust the low speed<br />
setting using the speed buttons (plus or minus) on<br />
the control panel.<br />
Humidity control + timer with light switch, wiring<br />
diagram 3<br />
The fan is connected using constant phase (L) and<br />
neutral (N) for automatic humidity control.<br />
Switched live (SL) is connected to activate the fan’s<br />
timer, i.e. when the bathroom light is switched on,<br />
current is present at switched live. This option offers<br />
a delayed start of 90 seconds before the fan starts.<br />
When the light is switched off, there is a delay of 5,<br />
15 or 30 minutes before the fan stops (post-running<br />
time), depending on your preferred control panel<br />
setting.<br />