- GB -<br />

5.4 Pump fed system without <strong>ProfiClear</strong> <strong>Premium</strong> Individual <strong>Modul</strong>e: Fitting the discharge set<br />

Fit an outlet adapter with DN 110 pipe bend to each DN 150 outlet to ensure a suitable level of water in<br />

the filter container. The height of the pipe bend outlet determines how high the water can rise in the filter<br />

containers. Based on the physical principle of communicating pipes, the water balances out to the same<br />

level in all containers. Ensure that the centre of the pipe bend outlet is 169 mm below the top edge of<br />

the container. It is not necessary to fit pipe bends if the last filter module is a <strong>ProfiClear</strong> <strong>Premium</strong><br />

Individual <strong>Modul</strong>e.<br />

OASE provides a suitable discharge set (Order No. 50949). It consists of two pipe bends/DN 110<br />

adapters with holding plate.<br />

4.<br />

How to proceed:<br />

H<br />

1. If not already done: Fit the sealing ring into the wall of the container from the outside.<br />

Ensure that the raised marking is at the top and aligned in relation to the hole pattern.<br />

2. Fit the outlet adapter to the sealing ring.<br />

Ensure that the raised marking is at the top and aligned in relation to the hole pattern.<br />

3. Fasten the sealing ring and outlet adapter from the inside with oval head screws.<br />

Tighten all screws diagonally using the cordless screwdriver to ensure that the sealing ring is<br />

uniformly applied. Further tighten the screws using a Phillips screwdriver.<br />

4. Fit the pipe bend set together in the specified order and fasten to the outlet adapter.<br />

5. Guide the holding plate over the pipe bend and align the pipe elements if necessary.<br />

6. Insert the screws with expansion seals through the holes from the inside. Screw the holding plate<br />

from the outside to the container wall with cap nuts.<br />

5.5 Returning the water to the pond<br />

Once it has passed through all the cleaning stages, the clean water has to be returned to the pond.<br />

There are various possibilities for this depending on the system used (please refer to the operating<br />

manual for the Individual <strong>Modul</strong>e).<br />