6 Commissioning/start-up<br />

7.<br />

- GB -<br />

Two 25 l bags of Hel-X biomedia (50 l) are required for operating a <strong>Moving</strong> <strong>Bed</strong> <strong>Modul</strong>e. Optionally, 75 l<br />

can be used (supplementary kit Order No.: 51060).<br />

How to proceed:<br />

1. Close the slide valve for the DN 75 dirt outlet at the bottom of the container.<br />

2. Check that the entire filter system (pipes and hoses) is complete.<br />

3. Fill the container with water:<br />

Pump fed system: Switch on the filter pump.<br />

Gravity fed system: Open the slide valves (supply and return) of the <strong>ProfiClear</strong> <strong>Premium</strong> filter<br />

series to allow the water to flow.<br />

4. Check all pipes, hoses and their connections for leaks.<br />

Expansion seals may leak initially until they have fully expanded on contact with water.<br />

5. Fill the container with Hel-X biomedia.<br />

Ensure that the Hel-X biomedia can move around freely in the container.<br />

It can take several weeks for the Hel-X biomedia to become completely colonised. Uncolonised<br />

Hex-X biomedia tend to float more.<br />

6. Add filter starter BioKick CWS.<br />

7. Fit the container cover.<br />

8. When all filter containers are filled with water, switch on the other electrical units (e.g. filter pumps).<br />

If using filter starters (e.g. OASE BioKick CWS), do not operate any UVC clarifying units for at least<br />

24 hours so as not to disturb the colonisation of the filter media by micro-organisms.<br />

7 Remedy of faults<br />

Malfunction Possible cause Remedy<br />

No flow of water<br />

Water flow insufficient<br />

Water contains too much<br />

ammonium/nitrite<br />

Hel-X biomedia are being<br />

flushed out<br />

Less movement of the Hel-<br />

X biomedia<br />

Less movement of the new<br />

Hel-X biomedia<br />

Filter pump not switched on Switch on the filter pump, connect the power plug<br />

Supply to filter system or return to pond<br />

blocked<br />

Clean the supply and/or return<br />

Bottom drain, pipe or hose blocked Clean, replace if necessary<br />

Hose kinked Check hose, and replace if necessary<br />

Excessive loss in lines Reduce line length to necessary minimum<br />

Insufficient Hel-X biomedia used Use more Hel-X biomedia if necessary<br />

Unit has only been in operation for a short<br />

time<br />

The full biological cleaning effect is only achieved<br />

after several weeks<br />

The meshed tube has slipped Correct the position of the meshed tube<br />

Defective meshed tube Replace the meshed tube<br />

Aerator rod is blocked Replace the aerator rod<br />

Aerator pump malfunction Check the aerator pump<br />

Hel-X biomedia are not yet fully colonised It takes several weeks for the biomedia to become<br />

colonised by bacteria. Wait for the natural process<br />

to take place.<br />

25