Wilo-TOP-E / TOP-ED / TOP-EV - NRF
Wilo-TOP-E / TOP-ED / TOP-EV - NRF
Wilo-TOP-E / TOP-ED / TOP-EV - NRF
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
1. General Information<br />
Assembly and installation should only be<br />
carried out by qualified personnel!<br />
1.1 Uses<br />
The circulating pump is used to transport liquids in<br />
warm water heating systems.<br />
Under no circumstances may the pump come in<br />
contact with drinking water or foodstuffs.<br />
1.2 Product data<br />
1.2.1 Key<br />
<strong>TOP</strong>-E 30/1-7<br />
Heating circulating pumps,<br />
wet runner motors<br />
E ➝ Electronics module<br />
<strong>ED</strong> ➝ Double pump with<br />
electronic module<br />
<strong>EV</strong> ➝ with built-in isolating valve<br />
<strong>EV</strong> ➝ and electronic module<br />
Nominal width DN of the connecting pipe [mm]<br />
Flange connection: 32 (for <strong>ED</strong>),<br />
Flange connection: 40, 50, 65, 80, 100<br />
(<strong>EV</strong> with all-purpose flange PN 6/10: 40, 50, 65)<br />
Screw connection: 25 (R 1), 30 (R 1&)<br />
level, adjustable nominal pump lift 1 to 7 m<br />
Hmin: 1 m, Hmax: 7 m<br />
1.2.2 Connection and output data<br />
– Flow media:<br />
– Heating water acc. to VDI 2035.<br />
– Water glycol mixtures containing up to 50 % glycol.<br />
Should glycol be added to the liquid, the flow<br />
data must be adapted to correspond to the<br />
higher viscosity. Only brand products with anticorrosion<br />
inhibitors should be used. The manufacturer’s<br />
instructions must always be strictly<br />
adhered to.<br />
– If another medium is to be used, it must be<br />
cleared by <strong>Wilo</strong>.<br />
– Temperature range of the flow medium: +20 °C to<br />
+110°C.<br />
– Max. ambient temperature: 40 °C.<br />
– In order to avoid the build up of condensation water,<br />
the temperature of the room must be lower the<br />
temperature of the flow medium.<br />
– Max. operating pressure of the pump: see rating<br />
plate.<br />
– Min. supply pressure at the air intake in order to<br />
avoid cavity noises (at max. water temperature T max):<br />
Tmax R1 R1& DN 40 (32) DN 50 DN 65 DN 80 DN 100<br />
1+50°C 0.05 bar 0.3 bar<br />
1+95°C 0.5 bar 1.0 bar<br />
+110°C 1.1 bar 1.6 bar<br />
These values are valid up to a height of 300 m<br />
above sea level. For situations above this height<br />
add 0.01 bar for every additional 100 m.<br />
– system of protection IP 43.<br />
– Connection to 1~230 V, 50 Hz in accordance with<br />
IEC 38.<br />
– When ordering spare parts, please give all the information<br />
on the pump/motor rating plate.<br />
2. Safety<br />
These instructions contain important information which<br />
must be followed when installing and operating the<br />
pump. It is therefore imperative that they be read by<br />
both the installer and the operator before the pump is<br />
installed or started up.<br />
Both the general safety points in this section and the<br />
more specific safety points in the following sections<br />
should be noted.<br />
2.1 Instruction symbols in this operating manual<br />
Safety precautions in these operating instructions<br />
which, if not followed, could cause personal injury are<br />
indicated by the symbol:<br />
Safety precautions warning of danger due to electricity<br />
are indicated by the symbol<br />
The following symbol is used to indicate that by ignoring<br />
the relevant safety instructions, damage could be<br />
caused to the pump/machinery and its functions:<br />
ATTENTION!<br />
ENGLISH<br />
2.2 Staff training<br />
The personnel installing the pump must have the<br />
appropriate qualifications for this work.<br />
19