English<br />

Operation<br />

Input terminal limits<br />

Switch<br />

«Function»<br />

Input<br />

terminals<br />

Min. display<br />

reading<br />

Max. display<br />

reading<br />

Max. input<br />

VDC<br />

VAC<br />

V/Ω/Hz<br />

COM<br />

V/Ω/Hz<br />

COM<br />

0.0001 V 1000.0 V 1000 VDC<br />

0.0001 V 750.0 V 750 VAC<br />

Ω<br />

V/Ω/Hz<br />

COM<br />

0.0001 kΩ 19.999 MΩ<br />

600 V<br />

(1 min)<br />

Dio<strong>de</strong> /<br />

Cont.<br />

V/Ω/Hz<br />

COM<br />

0.1 1999.9<br />

600 V<br />

(1 min)<br />

mADC mA COM 0.0001 mA 1999.9 mA 2 A<br />

mAAC mA COM 0.0001 mA 1999.9 mA 2 A<br />

ADC A COM 0.001 A 10.000 A 10.00 A<br />

AAC A COM 0.001 A 10.000 A 10.00 A<br />

Frequency<br />

V/Ω/Hz<br />

COM<br />

0.001 kHz 199.99 kHz<br />

600 V<br />

(1 min)<br />

Multimeter<br />

maintenance<br />

Fuse replacement<br />

• Switch off the instrument.<br />

• Unscrew the fuse hol<strong>de</strong>r located at the back of the instrument (16).<br />

• Take the <strong>de</strong>fect fuse away.<br />

• Replace with new fuse of same type.<br />

• Re-position the fuse hol<strong>de</strong>r.<br />

Warning !<br />

The fuses must be replaced only with fuses of same mo<strong>de</strong>l :<br />

200 mA, 250 V, fast.<br />

Case cleaning<br />

• Turn off the instrument.<br />

• Clean it with a damp cloth and soap.<br />

• Do not use abrasive products or solvents.<br />

• Leave to dry before using it again.<br />