Notice de fonctionnement - Multimetrix
Notice de fonctionnement - Multimetrix
Notice de fonctionnement - Multimetrix
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
English<br />
Operation<br />
Input terminal limits<br />
Switch<br />
«Function»<br />
Input<br />
terminals<br />
Min. display<br />
reading<br />
Max. display<br />
reading<br />
Max. input<br />
VDC<br />
VAC<br />
V/Ω/Hz<br />
COM<br />
V/Ω/Hz<br />
COM<br />
0.0001 V 1000.0 V 1000 VDC<br />
0.0001 V 750.0 V 750 VAC<br />
Ω<br />
V/Ω/Hz<br />
COM<br />
0.0001 kΩ 19.999 MΩ<br />
600 V<br />
(1 min)<br />
Dio<strong>de</strong> /<br />
Cont.<br />
V/Ω/Hz<br />
COM<br />
0.1 1999.9<br />
600 V<br />
(1 min)<br />
mADC mA COM 0.0001 mA 1999.9 mA 2 A<br />
mAAC mA COM 0.0001 mA 1999.9 mA 2 A<br />
ADC A COM 0.001 A 10.000 A 10.00 A<br />
AAC A COM 0.001 A 10.000 A 10.00 A<br />
Frequency<br />
V/Ω/Hz<br />
COM<br />
0.001 kHz 199.99 kHz<br />
600 V<br />
(1 min)<br />
Multimeter<br />
maintenance<br />
Fuse replacement<br />
• Switch off the instrument.<br />
• Unscrew the fuse hol<strong>de</strong>r located at the back of the instrument (16).<br />
• Take the <strong>de</strong>fect fuse away.<br />
• Replace with new fuse of same type.<br />
• Re-position the fuse hol<strong>de</strong>r.<br />
Warning !<br />
The fuses must be replaced only with fuses of same mo<strong>de</strong>l :<br />
200 mA, 250 V, fast.<br />
Case cleaning<br />
• Turn off the instrument.<br />
• Clean it with a damp cloth and soap.<br />
• Do not use abrasive products or solvents.<br />
• Leave to dry before using it again.<br />
18 Digital Benchtop Multimeter