Housings, Frames & special applications<br />
Filters for Gas Turbines<br />
<strong>Cam</strong> <strong>GT</strong> <strong>Box</strong> <strong>Type</strong><br />
Advantages<br />
• Suitable for high humidity<br />
conditions<br />
• Can be used to upgrade<br />
existing installations<br />
• Patented integrated water<br />
drainage<br />
• Very robust construction<br />
• Burst pressure = 7500 Pa<br />
• Corrosion resistant<br />
Application: Admission d’air de turbines à gaz<br />
<strong>Type</strong>: Filtre multidièdre compact haute efficacité<br />
Cadre: Polypropylène et ABS<br />
Joint: Polyuréthane expansé placé côté dièdre (code 01)<br />
Média: Papier fibre de verre<br />
Séparateurs: Cordons hot-melt<br />
Lut: Polyuréthane<br />
Grille: Grille de renfort fibre de verre placée en aval<br />
Efficacité EN779:2012: F7. F9<br />
Efficacité EN 1822: E10<br />
Perte de charge finale recommandée: 600 Pa<br />
Débit maximum: 5100m3/h<br />
Température: 80ºC maximum en service continu<br />
Nota: Pression d’éclatement : > 7500 Pa<br />
Country Product Reference <strong>Type</strong> Model<br />
Dimensions<br />
(WxHxD) mm<br />
Filter<br />
grade Air flow/pressure drop<br />
EN 779 m³/hr/Pa<br />
à 0,4 µm<br />
Media<br />
surface m2<br />
Unit<br />
weight kg<br />
Unit volume<br />
m3<br />
DE<br />
CAM <strong>GT</strong><br />
Turbinenfilter -<br />
Filterklasse F7,<br />
F9, E10<br />
232072SO<br />
CAM<br />
<strong>GT</strong>-F7<br />
CAM <strong>GT</strong> F7-<br />
242412/01<br />
592x592x290 F7 4250/120 19,00 7,00 0,110<br />
DE<br />
CAM <strong>GT</strong><br />
Turbinenfilter -<br />
Filterklasse F7,<br />
F9, E10<br />
232073SO<br />
CAM<br />
<strong>GT</strong>-F7<br />
CAM <strong>GT</strong> F7-<br />
241212/01<br />
592x287x290 F7 2125/145 9,00 5,00 0,050<br />
As part of our continuous improvement, <strong>Cam</strong>fil Farr reserve the right to change specifications without notice.<br />
DE<br />
DE<br />
UK<br />
UK<br />
UK<br />
UK<br />
SE<br />
SE<br />
SE<br />
SE<br />
CAM <strong>GT</strong><br />
Turbinenfilter -<br />
Filterklasse F7,<br />
F9, E10<br />
CAM <strong>GT</strong><br />
Turbinenfilter -<br />
Filterklasse F7,<br />
F9, E10<br />
CAM <strong>GT</strong> Gas<br />
Turbine Filter<br />
CAM <strong>GT</strong> Gas<br />
Turbine Filter<br />
CAM <strong>GT</strong> Gas<br />
Turbine Filter<br />
CAM <strong>GT</strong> Gas<br />
Turbine Filter<br />
CAM <strong>GT</strong> Gas<br />
Turbin<br />
CAM <strong>GT</strong> Gas<br />
Turbin<br />
CAM <strong>GT</strong> Gas<br />
Turbin<br />
CAM <strong>GT</strong> Gas<br />
Turbin<br />
232075SO<br />
232076SO<br />
1530.12.50<br />
1530.52.50<br />
1530.17.50<br />
1530.57.50<br />
1530.12.50<br />
1530.52.50<br />
1530.17.50<br />
1530.57.50<br />
FR CAM <strong>GT</strong> 1530.52.50<br />
CAM<br />
<strong>GT</strong>-F9<br />
CAM<br />
<strong>GT</strong>-F9<br />
CAM<br />
<strong>GT</strong>-F7<br />
CAM<br />
<strong>GT</strong>-F7<br />
CAM<br />
<strong>GT</strong>-F9<br />
CAM<br />
<strong>GT</strong>-F9<br />
CAM<br />
<strong>GT</strong>-F7<br />
CAM <strong>GT</strong> F9-<br />
242412/01<br />
CAM <strong>GT</strong> F9-<br />
241212/01<br />
CAM <strong>GT</strong> F7-<br />
242412/01<br />
CAM <strong>GT</strong> F7-<br />
241212/01<br />
CAM <strong>GT</strong> F9-<br />
242412/01<br />
CAM <strong>GT</strong> F9-<br />
241212/01<br />
CAM <strong>GT</strong> F7-<br />
242412/01<br />
CAM <strong>GT</strong> F7-<br />
241212/01<br />
CAM <strong>GT</strong> F9-<br />
242412/01<br />
CAM <strong>GT</strong> F9-<br />
241212/01<br />
C<strong>GT</strong>-HF-P-F7-<br />
592x287x292-01<br />
592x592x290 F9 4250/160 19,00 7,00 0,110<br />
592x287x290 F9 2125/180 9,00 5,00 0,050<br />
592x592x290 F7 4250/120 19,00 7,00 0,110<br />
595x287x290 F7 2125/145 9,00 5,00 0,050<br />
592x592x290 F9 4250/160 19,00 7,00 0,110<br />
595x287x290 F9 2125/180 9,00 5,00 0,050<br />
592x592x290 F7 4250/120 19,00 7,00 0,110<br />
592x287x290 F7 2125/145 9,00 5,00 0,050<br />
592x592x290 F9 4250/160 19,00 7,00 0,110<br />
592x287x290 F9 2125/180 9,00 5,00 0,050<br />
595x287x290 F7 2125/145 9,00 5,00 0,05<br />
www.camfilfarr.com
Housings, Frames & special applications<br />
Filters for Gas Turbines<br />
Country Product Reference <strong>Type</strong> Model<br />
Dimensions<br />
(WxHxD) mm<br />
Filter<br />
grade Air flow/pressure drop<br />
EN 779 m³/hr/Pa<br />
à 0,4 µm<br />
Media<br />
surface m2<br />
Unit<br />
weight kg<br />
Unit volume<br />
m3<br />
FR CAM <strong>GT</strong> 1530.12.50<br />
CAM<br />
<strong>GT</strong>-F7<br />
C<strong>GT</strong>-HF-P-F7-<br />
592x592x292-01<br />
592x592x290 F7 4250/120 19,00 7,00 0,11<br />
FR CAM <strong>GT</strong> 1530.57.50<br />
CAM<br />
<strong>GT</strong>-F9<br />
C<strong>GT</strong>-HF-P-F9-<br />
592x287x292-01<br />
595x287x290 F9 2125/180 9,00 5,00 0,05<br />
FR CAM <strong>GT</strong> 1530.17.50<br />
CAM<br />
<strong>GT</strong>-F9<br />
C<strong>GT</strong>-HF-P-F9-<br />
592x592x292-01<br />
592x592x290 F9 4250/160 19,00 7,00 0,11<br />
www.camfilfarr.com<br />
As part of our continuous improvement, <strong>Cam</strong>fil Farr reserve the right to change specifications without notice.