11.03.2014 Views

giada

giada

giada

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GIADA<br />

50 cm<br />

(1) In case of flues side by side, a chimney cap must be higher<br />

than the other one of at least 50 cm in order to avoid pressure<br />

transfers between the flues themselves.<br />

Picture 5<br />

2 m 10 m<br />

1<br />

m<br />

(1) The chimney cap must not show hindrances within 10 m from<br />

walls, pitches and trees. Otherwise raise it of at least 1 m over the<br />

hindrance.<br />

The chimney cap must exceed the ridge of the roof of at least 1 m.<br />

Picture 6<br />

> _ A<br />

>A<br />

0,5 m<br />

H min.<br />

(1)Ridge axis<br />

α<br />

(2)Roof<br />

Picture 7<br />

CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683/98<br />

Inclination of the<br />

roof<br />

Distance between the roof<br />

ridge and the stack<br />

Minimum height of the stack<br />

(measured from the outlet)<br />

α A (m) H (m)<br />

15°<br />

30°<br />

45°<br />

60°<br />

< 1.85 m 0.50 m above the roof ridge<br />

> 1.85 m 1.00 m from the roof<br />

< 1.50 m 0.50 m above the roof ridge<br />

> 1.50 m 1.30 m from the roof<br />

< 1.30 m 0.50 m above the roof ridge<br />

> 1.30 m 2.00 m from the roof<br />

< 1.20 m 0.50 m above the roof ridge<br />

> 1.20 m 2.60 m from the roof<br />