MAINTENANCE<br />

ATTENTION: The pre-filter basket (4), when present, must be periodically emptied and cleaned. A dirty or clogged basket<br />

decreases pump performance.<br />

Cleaning the frame<br />

1. Turn off the pump by disconnecting it from the electric network.<br />

2. Close any valves that are present.<br />

3. Unscrew the transparent cover (5) of the pre-filter (2).<br />

4. Remove the frame (4), empty it and carefully clean it.<br />

5. Insert the frame again (4) inside the pre-filter (2).<br />

6. Tightly fasten the transparent cover (4) of the pre-filter making sure that the OR gasket (3) is intact and correctly<br />

positioned in its proper housing.<br />

7. Open any valves that are present.<br />

8. Start the pump by connecting it to the electric network.<br />

ATTENTION: Should the pump turn off because the thermal breaker is triggered, disconnect the pump from the electric<br />

network and then dismantle the differential safety switch. Check whether the rotor turns freely as indicated in fig.4. If the<br />

rotor is blocked follow the steps described in the MALFUNCTION chapter. If the motor shaft turns freely, mount the<br />

differential safety switch and activate the pump by connecting it to the electric network; when the motor has cooled down<br />

the pump will begin to run again.<br />

If the thermal breaker should be triggered again frequently, have the pump checked by qualified personnel and make sure<br />

also the domestic electric network is inspected.<br />

ATTENTION: If the pump is blocked it must be cleaned! Repeated attempts at starting a blocked pump cause irreparable<br />

damage. In this case the warranty is no longer valid.<br />

ATTENTION: All extraordinary maintenance (replacement of mechanical gaskets, etc.) must be carried out by qualified<br />

personnel.<br />

WINTER STORAGE<br />

In winter the pump must be stored in a cool, dry place. If there is the risk of freezing, the pump must be carefully emptied<br />

from the liquids in its circuit. It is advisable to empty all the piping.<br />

MALFUNCTIONING<br />

A mechanical gasket is used to isolate the pump body and the motor body. Some drops of water may flow out once in a<br />

while – this is normal, especially after periods of non use.<br />

If the leaks are consistent contact the assistance center.<br />

ATTENTION: After a long period of inactivity check that the motor shaft turns freely. (Fig. 4). If the fan has difficulty in<br />

rotating or is jammed follow these steps:<br />

1. disconnect the pump from the electric network;<br />

2. manually turn the rotor for 9-10 rotations using a screwdriver as shown in Fig. 4.<br />

3. connect the pump to the electric network and start it.<br />

If the pump does not run contact the assistance centre.