Page 18 Notice technique EVP 3160 Version logiciel : 1.00<br />

Connexions EVP Entrées / Sorties<br />

Données techniques<br />

OUT (Signal 0-10V)<br />

Capteur<br />

de pression<br />

DG 0-25 HUB<br />

2<br />

1<br />

3<br />

IN<br />

GND<br />

PE<br />

EVP 3160<br />

Alim.<br />

230VAC<br />

N L<br />

1 2 3 4 5<br />

ATTENTION !!!<br />

Bien vérifier<br />

le type de bobine<br />

du dét. élect.<br />

33<br />

DO1<br />

Sortie dét. élect.<br />

230V DC / AC<br />

Alimentation ........................... 230V 50Hz, env. 6VA<br />

T°C fonctionnement ............... 0...+50°C<br />

Humidité fonctionnement ....... 85% r.F., non-condensée<br />

Entrées .................................. 4x sonde de température<br />

TF 501 (PT 1000)<br />

1x Capteur de pression 0-10V DC<br />

Entrées de commande ........... 2x 230V~, max. 3mA<br />

Relais de sortie ...................... 3x inverseurs, libre de tt pot.<br />

Puissance 8A cos phi=1/250VAC<br />

Relais statique ....................... 1x Solid-State-Relais (SSR)<br />

Puissance 1 A / 250VAC<br />

ou<br />

230V DC / 400mA<br />

Sortie analogique ................... 0...10V ou 4...20mA configurable<br />

Plage d'affichage / réglage ..... voir liste des paramètres<br />

Interfaces ............................... 2x RS-485, 1x CAN<br />

Sauvagarde des données ...... illimitée<br />

Horloge temps réel ................ commutation été / hiver, 10 jour de<br />

réserve de marche en cas de coupure<br />

d'alimentation<br />

Boîtier ............................. PVC avec touche folio<br />

pour montage sur rail DIN 35mm<br />

Bornier 2,5mm 2<br />

We state the following: When operated in accordance with the technical manual, the criteria have been met that are outlined in the guidelines of the<br />

council for alignment of statutory orders of the member states on EMC-Directive (2004/108/EC) and the Low Voltage Directive (LVD 2006/95/EC).<br />

This declarations are valid for those products covered by the technical manual which itself is part of the declaration. To meet the requirements, the<br />

currently valid versions of the relevant standards have been used<br />

This statement is made from the manufacturer / importer by:<br />

230V DC<br />

34 35 36 37 38 39 40 41 42<br />

Alimentation<br />

Capteur 24VDC<br />

DC<br />

DC<br />

6 7 8 9<br />

230V AC<br />

N<br />

Afficheur<br />

externe MA/SL<br />

DO<br />

NDO<br />

RS<br />

485<br />

DO2<br />

10<br />

Ventilation<br />

H<br />

L<br />

CAN<br />

DO3<br />

11 12 13 14<br />

Dégivrage<br />

Dimensions EVP<br />

EG-Statement of Conformity<br />

ELREHA Elektronische Regelungen GmbH Werner Roemer, Technical Director<br />

D-68766 Hockenheim, Schwetzinger Str. 103<br />

(name / adress) Hockenheim.............9.10.2008.......................................................<br />

DO<br />

E-Link<br />

NDO<br />

RS<br />

485<br />

43 44 45 46 47 48 49 50<br />

DO4<br />

15 16 17 18 19 20<br />

Libre<br />

EVP<br />

AO1<br />

4...20mA<br />

DI1<br />

Autorisation<br />

froid si 0V<br />

AO1<br />

0...10V<br />

DI2<br />

Libre<br />

!<br />

AI5<br />

Capteur 0...10V<br />

153 (6.02)<br />

51<br />

AI4<br />

Sonde PT1000<br />

P<br />

52 53 54 55 56<br />

AI3<br />

Sonde PT1000<br />

AI2<br />

Sonde PT1000<br />

ELREHA<br />

AI1<br />

Sonde PT1000<br />

63 (2.48)<br />

47 (1.85)<br />

93 (3.66)<br />

59 (2.32)<br />

39 (1.54)<br />

114 (4.49)<br />

26 (1.02)<br />

35(1.38)<br />

date: 14/08/2012, jr/tkd