RS-232 Communications Protocol & Command Set<br />

BATTERY LEVEL STATUS<br />

Requests the battery level, expressed as a percentage of maximum<br />

(full charge).<br />

Send Query to UPS:<br />

Action:<br />

Response:<br />

?BATTERYSTAT<br />

Load level will be displayed<br />

$BATTERY = xxx<br />

xxx is the battery charge level (percentage of maximum charge)<br />

expressed in decimal format. If the value is less than 100, the<br />

hundreds digit is represented with a 0.<br />

____________________________________________<br />

LIST CONFIGURATION<br />

Requests a list of all configurable parameters and current settings.<br />

Send Query to UPS:<br />

Action:<br />

?LIST_CONFIG<br />

List of configurable parameters and<br />

current settings will be displayed.<br />

Response:<br />

$BTHRESH = level<br />

$BUZZER = mode<br />

$AVR = mode<br />

$FEEDBACK = mode<br />

LINEFEED = mode<br />

$BRIGHTNESS = xxx<br />

$SCROLL_MODE = xxx<br />

$SLEEP_MODE = xxx<br />

____________________________________________<br />

List of all commands and queries<br />

Send Query to UPS:<br />

Action:<br />

Response:<br />

?HELP<br />

List of all commands and queries<br />

will be displayed<br />

!ALL_ON<br />

!ALL_OFF<br />

!SWITCH<br />

!SET_BATTHRESH<br />

!SET_BUZZER<br />

!SET_AVR<br />

!SET_FEEDBACK<br />

!SET_LINEFEED<br />

!RESET_ALL<br />

!SET_BRIGHT ?VOLTAGE<br />

!SET_SCROLLMODE ?LOADSTAT<br />

!SET_SLEEPMODE ?BATTERYSTAT<br />

?ID<br />

?LIST_CONFIG<br />

?OUTLETSTAT ?HELP<br />

?POWERSTAT<br />

_________________________________________<br />

RESPONSES & MESSAGES<br />

OUTLET STATUS CHANGE<br />

CONDITION<br />

RESPONSE<br />

Outlet Bank 1 changes state $BANK1 = status<br />

Outlet Bank 2 changes state $BANK2 = status<br />

status = {ON, OFF}<br />

_________________________________________<br />

POWER BUTTON STATUS CHANGE<br />

CONDITION<br />

Power Button changes<br />

ON/OFF status<br />

RESPONSE<br />

$BUTTON = status<br />

status = {ON, OFF}<br />

_________________________________________<br />

POWER FAULT STATUS CHANGE<br />

CONDITION<br />

Overvoltage State<br />

Undervoltage State<br />

Lost Power State<br />

Test Mode<br />

Recovery Mode<br />

Normal Operation Mode<br />

Low Battery<br />

AVR Stage<br />

Remaining Backup Time<br />

Battery State<br />

RESPONSE<br />

$PWR = OVERVOLTAGE<br />

$PWR = UNDERVOLTAGE<br />

$PWR = LOST POWER<br />

$PWR = TEST<br />

$PWR = RECOVERY<br />

$PWR = NORMAL<br />

$LOWBAT<br />

$AVRSTATE = state<br />

state = {BOOST, BUCK}<br />

$TIME = xxx<br />

xxx = backup time<br />

$BATTSTATE = xxx<br />

xxx = {CHARGE, DISCHARGE, FULL}<br />

Power Control Software<br />

Complete <strong>Instructions</strong> are available by clicking on Help on the<br />

Power Control Software welcome screen.<br />