50<br />
45<br />
25<br />
38<br />
30<br />
English<br />
Selecting the field angle and focusing the beam<br />
1. Press the locking lever push button and lift the locking lever to<br />
unlock the focus dial. See Figure 3.<br />
2. To reduce the field angle, rotate the focus dial clockwise. To<br />
enlarge the field angle, turn the focus dial anticlockwise.<br />
3. Once the desired field angle is established, slide the focus dial<br />
forward or backward to soften or sharpen the edge focus.<br />
4. Once the field and edge are established, press the locking<br />
lever back into position until it locks.<br />
Gel frame retaining clip<br />
The gel frame holder is equipped with a spring-loaded retaining<br />
clip that prevents gel frames and accessories from falling out of<br />
the holder.<br />
1. Release the retaining clip by pushing it sideways. The retaining<br />
clip pops open. See Figure 4.<br />
2. Insert the gel frame.<br />
3. Press the retaining clip down until it locks.<br />
Important: Lock retaining clip before you use the luminaire.<br />
Important: Use only the <strong>CE</strong> <strong>Source</strong> <strong>Four</strong> <strong>Zoom</strong> Colour frame<br />
(model number 407CF).<br />
Unlocked position<br />
Focus dial<br />
Locking lever<br />
push button<br />
Retaining clip<br />
Light baffle<br />
Figure 3<br />
Figure 4<br />
Gel notes<br />
For best results, always use a high quality, high temperature color<br />
medium. ETC does not guarantee performance with low<br />
temperature, saturated color gels.<br />
ETC's <strong>Source</strong> <strong>Four</strong> <strong>Zoom</strong> gel frame holder extender may help<br />
increase your gel life. (Accessory catalogue number 400PGE3)<br />
Contact ETC or your dealer for ordering information.<br />
10 • <strong>CE</strong> <strong>Source</strong> <strong>Four</strong> <strong>Zoom</strong>