- NetzanschluB mit dem Gegenstekker<br />

@ nach Schal tplan<br />

PM 001 985 -5 herstellen. Der<br />

AnschluB der Pumpe erfolgt Uber<br />

Stecker @ .<br />

Fig. 11<br />

•<br />

RUckseite <strong>TCP</strong> <strong>270</strong><br />

Rear of <strong>TCP</strong> <strong>270</strong><br />

Arriere du <strong>TCP</strong> <strong>270</strong><br />

NetzanschluB<br />

AnschluB <strong>TPH</strong> <strong>110</strong> oder <strong>TPU</strong> <strong>110</strong><br />

AnschluB <strong>Pumps</strong>tandkomponenten<br />

Anderung der BrUcken bei <strong>110</strong> V<br />

Schaltung auf Fig. 11 ist<br />

fur 220 V.<br />

AnschluB fUr Uberwachungsteil<br />

an b1-b2 nur donn erforderlich,<br />

wenn der Reloiskontakt d1 und<br />

d2 benutzt werden (Beschreibung<br />

unter 2.5).<br />

Bei dieser Anardnung sind die<br />

Druckschalter "pumping unit" und<br />

"heating" ouBer Funktion. AnschluB<br />

an Klemmleiste Kist nicht m6glich,<br />

do die Klemmen nur in Verbindung<br />

mit dem Relaissatz (Relois<br />

c7 cS) in Funktion sind.<br />

f<br />

2. Einsatz als Antriebselektronik<br />

und <strong>Pumps</strong>tandsteuerung mit Relois<br />

c7 und c8 (Relaissatz im<br />

Zubehor ongegeben).<br />

_ <strong>Pumps</strong>tandkomponenten on rvckseitiger<br />

Klemmleiste K onschlieBen<br />

(fUr Zugentlostung der Kabel sorgen,<br />

AnschluBleistung Vorpumpe<br />

max. 250 W).<br />

_ Relais c7 und c8 in das Gerot<br />

einsetzen.<br />

_ NetzanschluB mit dem Gegenstekker<br />

® nach Schal tplan<br />

PM 001 985 -5 herstellen.<br />

_ Ventilsteuergerat TCV kann nicht<br />

angeschlossen werden.<br />

- Make the power connection with<br />

matching plug @ in accordance<br />

with Wiring Diagram PM 001 985 -5.<br />

Connection of the pump is made<br />

over plug @ .<br />

@)<br />

@<br />

K<br />

Steuerprint<br />

Control print<br />

Circuit imprime de commande<br />

Power connection QD<br />

Connection of <strong>TPH</strong> <strong>110</strong> or <strong>TPU</strong> <strong>110</strong> CD<br />

Connection of pumping unit K<br />

components<br />

- Branchement secteur avec 10 contre-fiche<br />

@ selon schema electrique<br />

PM 001 985 -5.<br />

Cannexion de la pompe se fait<br />

par 10 fiche @ .<br />

Branchement secteur<br />

Branchement <strong>TPH</strong> <strong>110</strong> ou <strong>TPU</strong> <strong>110</strong><br />

Branchement composants du<br />

groupe de pompage<br />

Modification of the bridges ® Modification des ponts en <strong>110</strong><br />

for <strong>110</strong> V. Circuit in figure: V. Cablage sur la fig. en<br />

220 V.<br />

220 V.<br />

- Connection of monitoring section<br />

to b1-b2 only required if the<br />

relay contacts d1 and d2 are<br />

used (description in Point 2.5).<br />

For this application the push buttons<br />

"pumping unit" and "heating"<br />

are not working. Connection to<br />

the terminal strip is not possible<br />

because the terminals are only<br />

working in connection with the set<br />

af relays (relay c7, c8).<br />

2. As drive electronics and pumping<br />

unit control, with relays<br />

c7 and c8 (set of relays is indicated<br />

under accessories).<br />

- Connect the pumping unit components<br />

to the terminal strip K<br />

at the rear (provide for strain<br />

relief of the cables, connected<br />

rating of backing pump: max.<br />

250 W).<br />

- Insert relays c7 and c8 into the<br />

unit.<br />

- Make the power connection with<br />

matching plug ® in accordance<br />

with the Wiring Diagram<br />

PM 001 985 -5.<br />

- The valve control unit TCV cannot<br />

be connected.<br />

- Le branchement sur 10 partie contrale<br />

en b1-b2 n'est necessaire<br />

que lorsqu'on utilise les relois<br />

de contact d1 et d2 (description<br />

en 2.5).<br />

Pour cette application les interrupteurs<br />

d bouton "pumping unit"<br />

et "heating" sont hors fonction.<br />

Connexion d 10 reglette d barnes<br />

K n'est pas possible, parce que<br />

les bornes ne sont en fonction<br />

qu'en communication avec Ie jeu<br />

de relais (relais c7, cS).<br />

2. Utilisation comme commande<br />

electronique et commande de<br />

groupe de pampage c7 et c8<br />

(je de relais est indique sous<br />

accessoires).<br />

- Srancher les composants a l'arriere<br />

sur la reglette d barnes<br />

K (veiller d ce que les cables<br />

ne soient pas trop tendus, puissance<br />

absorbee pompe prima ire<br />

max. 250 W).<br />

- Placer les relais c7 et cS dons<br />

l'appareil.<br />

- Etablir Ie branchement secteur<br />

ovec 10 contre-fiche @selon<br />

schema electrique PM 002 985 -So<br />

- L'appareil de commande de vanne<br />

TeV nc peut pas etre branche.<br />

22