IMPORTANT: For 3-phase <strong>pump</strong>s, check for proper rotation before installing <strong>pump</strong> into basin. See figure A for proper<br />

rotation.<br />

4.<br />

Fig. A – Proper impeller<br />

rotation, three phase models<br />

AFTER THE PUMP IS INSTALLED, THE ELECTRICAL CHECKS OF SECTION 4 MUST BE PERFORMED.<br />

4-1 PIGGY BACK SWITCH OPERATION<br />

1. Plug the Piggyback switch into a 6-20R receptacle. The receptacle must be<br />

wired to a 30-amp breaker. Be sure to have the breaker turned off before<br />

plugging in the switch.<br />

2. Plug the <strong>pump</strong> power cord into the piggyback switch as shown.<br />

3. The <strong>pump</strong> is ready to test and your breaker can be turned on.<br />

(Refer to section 5)<br />

4-2 DIRECT WIRING OF AUTOMATIC PUMP<br />

The <strong>pump</strong> can run on a voltage rating of<br />

230V or 208V. Check that it is the same as<br />

the supply voltage. The <strong>pump</strong>s are<br />

supplied with 6-20P (20-amp) cord plug<br />

ends. If a single phase <strong>pump</strong> is to be wired<br />

directly into a control device or junction box,<br />

and it is necessary to remove the plugs,<br />

have a certified electrician do the wiring in<br />

accordance with the National Electric Code<br />

and applicable local codes. See Fig. B for<br />

direct wire installation of single phase,<br />

<strong>automatic</strong> <strong>pump</strong>s.<br />

Bottom<br />

View<br />

Electrical Connection<br />

ALWAYS TURN OFF BREAKERS BEFORE<br />

WORKING ON ELECTRICAL CORDS.<br />

BE CAREFUL NOT TO DRILL OR SCREW INTO<br />

EXISTING WIRING.<br />

1. The control panel is preferably mounted<br />

in a cool, dry environment. Installation<br />

and connections are specific to the<br />

control panel. Control panels should be<br />

installed and serviced only by a<br />

qualified electrician (Refer to Figure 2, page 10).<br />

Check three phase <strong>pump</strong>s for proper<br />

rotation prior to installing <strong>pump</strong>(s) in<br />

basin. To change rotation, reverse any<br />

two of the three power leads to the<br />

<strong>pump</strong>. Code the wires for reconnection<br />

after installation.<br />

Check to make sure installation is in accordance<br />

with the National Electric Code and all applicable local codes. Installation and servicing is to be<br />

conducted by qualified personnel. This <strong>pump</strong> is supplied with a grounding conductor. To reduce<br />

the risk of electrical shock, be certain that it is connected to a properly grounded earth wire.<br />

Fig. B – Direct Wiring of 120V or 208-<br />

230V Single Phase, Automatic Pumps<br />

©Copyright 2010 Liberty Pumps Inc. All rights reserved - 6 -