Warning Type of Malfunction / Cause Possible Cause Possible Clearance<br />

A13 - Filling failure at the start of<br />

steaming in the first 3<br />

minutes, i.e. lower and<br />

upper water levels not<br />

reached (e.g. during initial<br />

start-up)<br />

- Solenoid valve error<br />

- Level sensor error<br />

(Symptom: Water emerges<br />

from the drain pipe during<br />

steam operation)<br />

- Steam module error<br />

A14 - Filling at the start of<br />

steaming in the first 3<br />

minutes insufficient, i.e.<br />

lower water level reached,<br />

but not upper water level<br />

A16 - Maximum cabin<br />

temperature of 55°C<br />

exceeded<br />

A17 - Drain process of steam<br />

generator defective<br />

A18 - Measured values from<br />

cabin temperature sensor<br />

out of tolerance<br />

A19 - Steam generator is filled up<br />

or is filled particular when<br />

starting<br />

- Ball valve before steam<br />

generator closed<br />

- Filter in connection bracket<br />

of steam generator clogged<br />

- Insufficient on-site water<br />

supply<br />

- Solenoid valve defective or<br />

disconnected<br />

- Level sensor defective or<br />

disconnected<br />

- Steam module defective or<br />

no voltage supply<br />

- Ball valve before steam<br />

generator closed<br />

- Filter in connection bracket<br />

of steam generator clogged<br />

- Insufficient on-site water<br />

supply<br />

- Solenoid valve defective or<br />

disconnected<br />

- Safety cut-out when<br />

maximum allowed cabin<br />

temperature exceeded<br />

- Generator calcified, i.e. drain<br />

outlet and / or pipe clogged<br />

- Cabin temperature sensor<br />

defective or disconnected<br />

- Solenoid valve defective<br />

(untight)<br />

As soon as a warning is displayed, the steam function can no longer be used!<br />

- Open ball valve<br />

- Clean filter in connection<br />

bracket<br />

- Ensure sufficient water<br />

supply<br />

- Replace solenoid valve<br />

membrane or connect<br />

cable (cable on steam<br />

module with “Fill” marking)<br />

- Replace level sensor or<br />

connect cable (cable on<br />

steam module with “Level”<br />

marking)<br />

- Replace steam module or<br />

connect cable (cable on<br />

steam module with “Mains<br />

230V” marking)<br />

- Open ball valve<br />

- Clean filter in connection<br />

bracket<br />

- Ensure sufficient water<br />

supply<br />

- Replace solenoid valve<br />

membrane or connect<br />

cable (cable on steam<br />

module with “Fill” marking)<br />

- Allow cabin to cool down<br />

- Remove generator and<br />

clean generator including<br />

drain pipe<br />

- Replace or connect cabin<br />

temperature sensor<br />

- Clean solenoid valve<br />

membrane or replace it<br />

Warnings can be not deleted; press the light push-button to ignore a warning. If the functional state does not change, the<br />

warning is displayed again when the respective function is selected again.<br />

After pressing the light push-buttom at warning A19, an automatic drain process of steam generator will be starting.<br />

Error messages can be eliminated without loss of data with a mains reset (switching the FI switch off and on again after 10<br />

seconds).<br />