Warning Type of Malfunction / Cause Possible Cause Possible Clearance<br />
A13 - Filling failure at the start of<br />
steaming in the first 3<br />
minutes, i.e. lower and<br />
upper water levels not<br />
reached (e.g. during initial<br />
start-up)<br />
- Solenoid valve error<br />
- Level sensor error<br />
(Symptom: Water emerges<br />
from the drain pipe during<br />
steam operation)<br />
- Steam module error<br />
A14 - Filling at the start of<br />
steaming in the first 3<br />
minutes insufficient, i.e.<br />
lower water level reached,<br />
but not upper water level<br />
A16 - Maximum cabin<br />
temperature of 55°C<br />
exceeded<br />
A17 - Drain process of steam<br />
generator defective<br />
A18 - Measured values from<br />
cabin temperature sensor<br />
out of tolerance<br />
A19 - Steam generator is filled up<br />
or is filled particular when<br />
starting<br />
- Ball valve before steam<br />
generator closed<br />
- Filter in connection bracket<br />
of steam generator clogged<br />
- Insufficient on-site water<br />
supply<br />
- Solenoid valve defective or<br />
disconnected<br />
- Level sensor defective or<br />
disconnected<br />
- Steam module defective or<br />
no voltage supply<br />
- Ball valve before steam<br />
generator closed<br />
- Filter in connection bracket<br />
of steam generator clogged<br />
- Insufficient on-site water<br />
supply<br />
- Solenoid valve defective or<br />
disconnected<br />
- Safety cut-out when<br />
maximum allowed cabin<br />
temperature exceeded<br />
- Generator calcified, i.e. drain<br />
outlet and / or pipe clogged<br />
- Cabin temperature sensor<br />
defective or disconnected<br />
- Solenoid valve defective<br />
(untight)<br />
As soon as a warning is displayed, the steam function can no longer be used!<br />
- Open ball valve<br />
- Clean filter in connection<br />
bracket<br />
- Ensure sufficient water<br />
supply<br />
- Replace solenoid valve<br />
membrane or connect<br />
cable (cable on steam<br />
module with “Fill” marking)<br />
- Replace level sensor or<br />
connect cable (cable on<br />
steam module with “Level”<br />
marking)<br />
- Replace steam module or<br />
connect cable (cable on<br />
steam module with “Mains<br />
230V” marking)<br />
- Open ball valve<br />
- Clean filter in connection<br />
bracket<br />
- Ensure sufficient water<br />
supply<br />
- Replace solenoid valve<br />
membrane or connect<br />
cable (cable on steam<br />
module with “Fill” marking)<br />
- Allow cabin to cool down<br />
- Remove generator and<br />
clean generator including<br />
drain pipe<br />
- Replace or connect cabin<br />
temperature sensor<br />
- Clean solenoid valve<br />
membrane or replace it<br />
Warnings can be not deleted; press the light push-button to ignore a warning. If the functional state does not change, the<br />
warning is displayed again when the respective function is selected again.<br />
After pressing the light push-buttom at warning A19, an automatic drain process of steam generator will be starting.<br />
Error messages can be eliminated without loss of data with a mains reset (switching the FI switch off and on again after 10<br />
seconds).<br />