2. The plasma arc can cause injury and burns.<br />
2.1 Turn off power before disassembling torch.<br />
2.2 Do not grip material near cutting path.<br />
2.3 Wear complete body protection.<br />
3. Electric shock from torch or wiring can kill.<br />
3.1 Wear dry insulating gloves. Do not wear wet or<br />
damaged gloves.<br />
3.2 Protect yourself from electric shock by insulating<br />
yourself from work and ground.<br />
3.3 Disconnect input plug or power before working on<br />
machine.<br />
4 Breathing cutting fumes can be hazardous to your<br />
health.<br />
4.1 Keep your head out of fumes.<br />
4.2 Use forced ventilation or local exhaust to remove<br />
fumes.<br />
4.3 Use ventilating fan to remove fumes.<br />
5 Arc rays can burn eyes and injure skin.<br />
5.1 Wear hat and safety glasses. Use ear protection and<br />
button shirt collar. Use welding helmet with correct<br />
shade of filter. Wear complete body protection.<br />
6 Become trained and read the instructions before<br />
working on the machine or cutting.<br />
7 Do not remove or paint over (cover) the label.<br />
2 GENERAL DESCRIPTION<br />
This equipment is a direct current continuous power<br />
source designed for plasma arc cutting of electro-conducting<br />
materials (metals and alloys). The plasma gas can<br />
be air or nitrogen.<br />
2.1 TORCH ASSEMBLY (Fig. 1)<br />
Insert the torch fitting into the guard R, then onto the fitting<br />
P, firmly tightening the ring-nut to avoid air leaks that<br />
could damage or interfere with smooth operation of the<br />
torch.<br />
Do not dent the current pin or bend the pegs of the torch<br />
fitting. A dented pin may not disconnect, while a bent peg<br />
does not allow proper insertion onto the fixed fitting P,<br />
thereby preventing the machine from working.<br />
8<br />
W<br />
Use the screws provided to fasten the guard R on to the<br />
panel.<br />
If torches for automatic cutting are used, connect the<br />
earth cable to the terminal W.<br />
2.2 DESCRIPTION OF DEVICES ON THE MACHINE<br />
A) Power cord<br />
B) Compressed air fitting (1/4" female gas thread)<br />
C) Mains power switch<br />
E) Pressure regulator knob<br />
F) Pressure gauge<br />
G) Thermostat LED<br />
H) Grounding clamp<br />
I) Water trap<br />
L) Low air pressure LED<br />
M) Cutting current regulator knob<br />
P) Torch fitting<br />
R) Safety guard<br />
S) Blocked LED; lights when hazardous conditions<br />
arise.<br />
T) Push-button to activate and deactivate the "SELF-<br />
RESTART PILOT" function.<br />
U) Plasma torch.<br />
V) Mains power led.<br />
W) Earth terminal for straight torches.<br />
2.3 SAFETY DEVICES<br />
This system comes equipped with the following safety<br />
devices:<br />
Overload cutout:<br />
1) To avoid overloads. It is evidenced by the G led<br />
continuosly on (see fig.1).<br />
Pneumatic:<br />
Located on the torch inlet to prevent low air pressure.<br />
The LED L lights when tripped (see fig.1).<br />
The blinking L led means that the pressure has temporarily<br />
gone below 3.2 ÷ 3.5 bar.<br />
Electrical:<br />
Located on the torch body, to prevent hazardous voltages<br />
from occurring on the torch when, swirl ring, electrode or<br />
➡➡<br />
Fig.1