13.07.2015 Views

Untitled - Platon-implant.com

Untitled - Platon-implant.com

Untitled - Platon-implant.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

6) Cases of dense boneWhere the bone at the <strong>implant</strong> site is closely taken up by <strong>com</strong>pactbone, or is covered by 2mm-3mm of <strong>com</strong>pact cortical bone, be sureto prepare the cortical bone layer using special tapping instruments.The need for tap preparation should be determined while evaluatingthe bone quality during drilling, or the <strong>implant</strong> placement in preparationof the <strong>implant</strong> socket. Also, where the need for tap preparationwas determined, and the <strong>implant</strong> placement is stopped once the tappreparation is done, we are asking you to place another new <strong>implant</strong>.Conduct the tap preparation while controlling bone burns throughsufficient irrigation, and preventing burr formations and clogging withcutting chips due to low speed rotation. Use special tapping instrumentscorresponding to <strong>implant</strong> sizes.Tapping instrumentsThese are instruments for tap preparation. Because the lengthof the tap part is set longer than that of the self tap provided to the<strong>implant</strong>s, tap preparation can be performed smoothly, and the <strong>implant</strong>placement can be made with a minimum of resistance to <strong>implant</strong>insertion. There are two types, for 8-10mm and 12-14mm by theintraosseous length of different sizes ( φ 3.3, φ 3.8, and φ 4.7).Chapter 6 Surgical formø 3.3 ø 3.8 ø 4.7Total length: 25.5mm1.2mmMaterial: Stainless steel (TiN coating)The placement should be made to match the grooves formed bytaps with <strong>implant</strong> threads.For dense bone, because the accumulation of bone cutting chipsin the <strong>implant</strong> socket may cause an increase in the placing resistance,place the <strong>implant</strong> following thorough cleaning of the<strong>implant</strong> socket after tap preparation.Where <strong>implant</strong>s are <strong>com</strong>pletely placed, prepare the bone up tothe top of the instruments. Also, where placement of the polishedsurface is controlled, prepare the bone based on a lasermark.27 SURGICAL MANUAL FOR PLATON IMPLANT SYSTEM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!