<strong>Metaloterm</strong> G<br />
Dubbelwandige gasafvoeren voor atmosferische, gasgestookte toestellen<br />
Total Solutions in Chimney Systems
Inhoudsopgave<br />
Toepassingsgebied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1<br />
Voorbereiding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1<br />
Installatie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />
Keuze diameter <strong>Metaloterm</strong> AG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />
Bevestigingsmiddelen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />
Aansluiting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />
Opbouw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />
Verslepingen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />
Dakdoorvoer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />
Uitmonding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />
Onderhoud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />
Algemeen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />
Bijlage 1: Bepaling van diameter uit de tabel . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />
Bijlage 2: Constructiedetails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />
Figuur 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />
Figuur 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
Figuur 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
Figuur 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
Figuur 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
Figuur 5a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
Figuur 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
Figuur 6a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
Figuur 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
Figuur 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />
Figuur 8a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
Figuur 8b . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
Figuur 8c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />
Figuur 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
Figuur 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21<br />
Montage handleiding <strong>Metaloterm</strong> AG . . . . . . . . . . . . . . . . . . . . . . . . . 22
Installatievoorschrift METALOTERM AG<br />
Toepassingsgebied:<br />
METALOTERM AG is geschikt voor toepassing op stooktoestellen voor genormeerde<br />
gasvormige brandstoffen met een rookgastemperatuur van maximaal 250°C en een<br />
schoorsteenverlies van ≥ 17%.<br />
Het rookkanaal dient in onderdruk-omstandigheden te functioneren, dat wil zeggen:<br />
de heersende druk in het rookkanaal dient onder gebruiksomstandigheden altijd lager<br />
te zijn dan de omgevingsdruk. METALOTERM AG is ongeschikt voor overdruk.<br />
Gebruik uitsluitend originele METALOTERM AG onderdelen en accessoires.<br />
Veranderingen en aanpassingen kunnen de goede werking nadelig beïnvloeden.<br />
Eventuele aanspraken op garantie komen door dergelijke wijzigingen te vervallen.<br />
Voorbereiding:<br />
Alvorens met de installatie te beginnen wordt het beoogde tracé, de plaats van de<br />
ravelingen, sparingen in wanden, vloeren en het dak, en eventuele obstakels als balken,<br />
gordingen etc. ingemeten. Bij het aanbrengen van sparingen dient de sterkte van<br />
de oorspronkelijke constructie niet ontoelaatbaar beïnvloed te worden.<br />
De sparingen in de onbrandbare vloeren dienen 20 millimeter groter te zijn dan de uitwendige<br />
diameter van het kanaal.<br />
De minimale afstand van de buitenwand van het METALOTERM AG kanaal tot brandbare<br />
materialen is 25 mm.<br />
Binnen het gebouw, en bij doorvoering door een wand of vloer waar de voorgeschreven<br />
brandwerendheid van de bouwconstructie nadelig beïnvloedt wordt, dient er een<br />
omkokering toegepast te worden. Zie voorbeelden zoals aangegeven op pagina’s 8 t<br />
/m 10. Deze uitvoeringen voldoen aan de eisen die gesteld worden met betrekking tot<br />
de weerstand tegen branddoorslag-brandoverslag (WBDBO), zoals vermeld in het<br />
Bouwbesluit met een minimum van 20 minuten.<br />
Bij een brandwerendheid van 20 minuten is geen omkokering nodig. Hierbij dient echter<br />
rekening gehouden te worden dat de oppervlakte-temperatuur van het AG-systeem<br />
tot een afstand van 1 meter vanaf het toestel (de verbinding tussen toestel en<br />
rookgasafvoer) hoger kan zijn dan 75K en dient de afstand tot brandbaar materiaal<br />
50 i.p.v. 25 mm te bedragen.<br />
Omkokeringen kunnen worden samengesteld uit:<br />
- onbrandbare plaat met een minimumdikte van 12 mm (bijvoorbeeld Nobranda);<br />
- metselwerk uit baksteen of kalkzandsteen, minimumdikte 50 mm;<br />
- gasbetonblokken of gipsblokken, minimaal 50 mm dik;<br />
- betonwanden.<br />
Omkokeringen zijn in principe 4-zijdig, echter tegen wanden van metselwerk, beton<br />
of gasbeton kunnen de omkokeringen 3-zijdig zijn. Indien het kanaal geplaatst wordt<br />
in een hoek tussen twee samenkomende wanden bestaande uit één van de eerder<br />
genoemde materialen kan de omkokering 2-zijdig samengesteld worden.<br />
Materialen welke zich aan de binnenzijde van de omkokering bevinden dienen<br />
onbrandbaar te zijn.<br />
1<br />
GASTEC G 11/97
Installatie:<br />
Voorkeur verdient de opbouw van onderaf. Raadpleeg en volg de montagehandleiding,<br />
welke in de verpakking van de metersecties is bijgevoegd. Een voorbeeldexemplaar<br />
is als bijlage aan dit installatievoorschrift toegevoegd.<br />
De montagehandleiding geeft belangrijke informatie over de juiste positie van de elementen.<br />
Let vooral op de juiste stromingsrichting van de rookgassen zoals aangegeven op de<br />
elementen. Een ondersteboven gemonteerd kanaal is niet toegestaan en zal tot<br />
klachten leiden.<br />
Keuze diameter METALOTERM AG:<br />
De diameter wordt vooraf bepaald door de totale lengte, inclusief aansluitleiding en<br />
het verloop van het rookkanaal (zoals bij inmeten is vastgesteld), de capaciteit en het<br />
type toestel.<br />
Een te grote of te kleine diameter kan leiden tot condensatie en/of verminderde trek in<br />
het rookkanaal, waardoor er verbrandingsgassen in de verblijfsruimte kunnen stromen.<br />
Een te geringe schoorsteenhoogte (minder dan 3 meter) kan problemen geven, vooral<br />
bij het optreden van valwinden (tussen hoge gebouwen). De diameter kan benaderd<br />
worden zoals aangegeven in bijlage 1 op pagina 4. Voor een uitgebreide berekening<br />
van de afvoerdiameter dient de methode volgens NEN 2757 toegepast te<br />
worden.<br />
Bevestigingsmiddelen:<br />
Nadat de toe te passen onderdelen bepaald zijn, wordt de hartlijn van het tracé op de<br />
wanden aangebracht, en wordt de plaats van de bevestigingsmiddelen bepaald.<br />
Vervolgens kunnen de bevestigingsmiddelen aangebracht worden waarbij men rekening<br />
moet houden met een eventueel noodzakelijke omkokering.<br />
Kies de lengte en de plaats van de secties zodanig, dat de verbinding tussen twee<br />
elementen zich niet in een doorvoering bevindt en niet samenvalt met bevestigingshulpstukken.<br />
Aansluiting:<br />
Het stooktoestel wordt altijd aangesloten op het METALOTERM AG kanaal met<br />
behulp van een aansluitstuk (code GA) waarbij het gewicht van de schoorsteen niet<br />
rechtstreeks op het stooktoestel mag rusten. Alleen op deze manier wordt een vrije<br />
thermische uitzetting gewaarborgd. Voor de verschillende uitvoeringen van de aansluitingen:<br />
zie ook figuur 9 op pagina 20.<br />
Opbouw:<br />
Direct boven het aansluitstuk GA wordt het eerstvolgende element met behulp van<br />
een muurbeugel aan de bouwkundige constructie bevestigd. Vervolgens worden alle<br />
secties en eventuele bochten aangebracht en bevestigd. Tenminste voor elke eerste<br />
bocht en na de volgende bocht dient er een bevestiging aan de bouwkundige constructie<br />
aangebracht te worden, zoals aangegeven in de constructiedetails op pagina<br />
7 e.v.<br />
2
Verslepingen:<br />
Indien verslepingen niet te vermijden zijn, dan dienen bochten spanningsvrij gemonteerd<br />
te worden zoals aangegeven in figuur 1, pagina 7. Een rechte schoorsteen<br />
garandeert de beste trek.<br />
Dakdoorvoer:<br />
Eventueel aanwezige omkokering moet door het dakbeschot aangebracht worden<br />
(zie figuur 3 en 4 op pagina’s 9 en 10). Denk aan de afstand tot brandbare<br />
materialen van 25 mm. Juist onder het dakbeschot dient een muurbeugel geplaatst<br />
te worden.<br />
Breng daarna de geëigende dakplaat en stormkraag aan zoals in figuur 10 op pagina<br />
21 aangegeven is.<br />
Uitmonding:<br />
Goede werking:<br />
Gebruik voor de uitmonding altijd de voorgeschreven <strong>Metaloterm</strong> trekkende kap<br />
(code GK). De uitmondingshoogte wordt bepaald volgens de situatieschets volgens<br />
figuur 8 en 8a op pagina’s 16 en 17, overeenkomstig met NEN 2757.<br />
Hinder:<br />
Ter voorkoming van hinder door de rookgassen ventilatie- en/of verbrandingsluchttoevoeropeningen<br />
(van hetzelfde perceel) dient voldoende afstand in acht genomen<br />
te worden. De korst mogelijke afstand tussen uitmonding en toevoer is bepalend.<br />
Op pagina’s 18 en 19 is een overzicht opgenomen, conform de situaties 1, 8 en 9<br />
uit NEN 2757.<br />
Onderhoud:<br />
Het rookkanaal moet 1 maal per jaar geïnspecteerd worden en eventueel geveegd.<br />
Dit dient bij voorkeur door een erkend schoorsteenreinigingsbedrijf, aangesloten bij<br />
de ASPB, te geschieden.<br />
Algemeen:<br />
Draag zorg voor een onbelemmerde toevoer van ventilatie- en verbrandingslucht, bij<br />
voorkeur rechtstreeks van buiten. Hierdoor wordt onderdruk en dus rookgaslekkage<br />
in de woning voorkomen.<br />
3
Bijlage 1: Bepaling van diameter uit de tabel<br />
Tabel 1 is geldig voor een enkelvoudige METALOTERM afvoerleiding<br />
De kenmerkende afmetingen, zoals aangegeven in figuur 1, zijn:<br />
- de totale hoogte (H), dat is de verticale afstand tussen de bovenkant van de trekonderbreker<br />
en de onderkant van de schoorsteenkap;<br />
- de horizontale lengte (L), dat is de horizontale afstand tussen de trekonderbreker<br />
en het verticale gedeelte van de afvoerleiding.<br />
Tabel 1 dient als volgt te worden gebruikt:<br />
1. zoek in de eerste verticale kolom de totale hoogte (h) in m;<br />
2. zoek naast de gevonden totale hoogte, in de tweede verticale kolom, de horizontale<br />
lengte (l) in m (=0 voor een geheel verticale afvoer),<br />
3. zoek in de daarnaast gelegen regel de capaciteit in kW die overeenkomt met de<br />
basiscapaciteit van het toestel of de naastliggende hogere capaciteit;<br />
4. ga van deze capaciteit omhoog en lees zodoende de diameter in mm van de<br />
afvoerleiding af.<br />
Een voorbeeld van een enkelvoudige afvoerleiding toont fig. 2. De gasketel heeft een<br />
capaciteit van 38,38 kW en een trekonderbreker met een diameter van 150 mm.<br />
Werkwijze:<br />
Ga van boven naar beneden in de eerste kolom tot u de hoogte 6 meter vindt en daarnaast<br />
de horizontale lengte 3 meter. In de kolom voor 130 mm diameter vindt u een<br />
capaciteit van 39,19 kW<br />
Condensatie:<br />
Afvoerleidingen die een uitzonderlijk grote lengte hebben in verhouding tot hun<br />
diameter, kunnen aanleiding geven tot condensatie. Een vuistregel om dat te<br />
ontgaan luidt:<br />
- totale lengte in m x 0,18 diameter in mm niet overschrijden waarin:<br />
- totale lengte = totale hoogte + horizontale lengte (H + L).<br />
Volgens deze regel zal een afvoerleiding van bijv. 100 mm diameter een totale lengte<br />
van 0,18 x 100 = 18 m niet moeten overschrijden.<br />
Minimale afvoerhoogte:<br />
Zoals uit de tabel blijkt, is een totale hoogte van minder dan 1 m niet aan te bevelen.<br />
Ingeval het gastoestel een luchtverhitter is die lucht uit een beperkte opstellingsruimte<br />
aanzuigt, dient de totale hoogte niet minder dan 2 meter te zijn. Raadpleeg voor<br />
ventilatie-openingen en afmetingen NEN 1078 en NEN 2757.<br />
4
Verdere richtlijnen bij het bepalen van diameter en lengte:<br />
Minimale diameter van de leiding. In geval de met de tabel gevonden diameter kleiner<br />
is dan die van de trekonderbreker van het toestel, dient het volgende in acht te worden<br />
genomen:<br />
- wanneer de totale hoogte kleiner is dan 3 m en geheel verticaal, mag pas verkleind<br />
worden na de eerste 0,5 m verticaal; bij voorkeur met niet méér dan één diameter<br />
verkleining.<br />
Compensatie voor extra bochten:<br />
Voor capaciteiten, geldend voor enkelvoudige afvoerleidingen met horizontale gedeelten,<br />
houdt de tabel rekening met twee bochten 90°, ergens tussen de trekonderbreker<br />
en de afvoerkap.<br />
a. 2 bochten van 90°<br />
b. 1 bocht van 90° en 1 T-stuk<br />
c. 4 bochten van 45°.<br />
minimale hoogte<br />
0.5 m<br />
L<br />
figuur 1<br />
H<br />
5<br />
3 m<br />
figuur 2<br />
6 m
Tabel 1<br />
- Tabel voor enkelvoudige afvoerleidingen.<br />
- Maximum netto ketelcapaciteit in kW (1 kW = 0.86 Mcal)<br />
- H en L in meters<br />
- Diameter afvoerleiding in mm<br />
H L 90 100 110 130 150 180 200<br />
1.0 0.0<br />
0.5<br />
12.0<br />
8.9<br />
15.5<br />
11,8<br />
18.0<br />
14.7<br />
26.6<br />
20.4<br />
35.7<br />
27.2<br />
52.0<br />
39.5<br />
64.5<br />
49.1<br />
1.5 0.0<br />
0.5<br />
1.0<br />
13.2<br />
10.9<br />
10.3<br />
18.1<br />
14.1<br />
13.7<br />
22.6<br />
17.6<br />
17.1<br />
31.5<br />
24.4<br />
24.0<br />
42.4<br />
32.8<br />
32.2<br />
62.1<br />
47.8<br />
47.1<br />
77.2<br />
59.3<br />
58.5<br />
2.0 0.0<br />
0.5<br />
1.0<br />
1.5<br />
15.5<br />
12.4<br />
11.7<br />
11.0<br />
20.1<br />
15.9<br />
15.6<br />
15.2<br />
25.1<br />
19.9<br />
19.4<br />
19.0<br />
35.2<br />
27.6<br />
27.1<br />
26.6<br />
47.7<br />
37.2<br />
36.6<br />
36.1<br />
70.0<br />
54.3<br />
53.6<br />
52.9<br />
87.2<br />
67.6<br />
66.8<br />
65.9<br />
2.5 0.0<br />
0.5<br />
1.0<br />
1.5<br />
16.3<br />
13.2<br />
12.8<br />
12.2<br />
21.8<br />
17.5<br />
17.0<br />
16.6<br />
27.2<br />
21.7<br />
21.3<br />
20.8<br />
38.3<br />
30.4<br />
29.8<br />
29.3<br />
52.0<br />
40.9<br />
40.4<br />
39.7<br />
76.4<br />
59.9<br />
59.1<br />
58.4<br />
95.5<br />
74.7<br />
73.7<br />
72.8<br />
3.0 0.0<br />
0.5<br />
1.0<br />
1.5<br />
17.9<br />
14.0<br />
13.6<br />
13.3<br />
23.0<br />
18.6<br />
18.3<br />
17.9<br />
29.0<br />
23.3<br />
22.8<br />
22.6<br />
40.8<br />
32.7<br />
32.1<br />
31.5<br />
55.5<br />
44.2<br />
43.5<br />
42.8<br />
81.9<br />
64.8<br />
63.8<br />
63.0<br />
102.5<br />
80.7<br />
79.8<br />
78.7<br />
4.5 0.0<br />
0.5<br />
1.0<br />
2.3<br />
19.0<br />
15.4<br />
15.4<br />
13.8<br />
25.8<br />
21.5<br />
21.2<br />
20.2<br />
32.7<br />
27.0<br />
25.7<br />
25.5<br />
46.3<br />
38.0<br />
37.4<br />
36.1<br />
63.5<br />
51.8<br />
51.1<br />
49.3<br />
94.4<br />
76.3<br />
75.4<br />
73,2<br />
118.6<br />
95.4<br />
94.3<br />
91.8<br />
6.0 0.0<br />
0.5<br />
1.0<br />
3.0<br />
20.1<br />
16.2<br />
16.2<br />
15.4<br />
27.7<br />
23.6<br />
23.1<br />
21.7<br />
35.1<br />
30.8<br />
29.2<br />
27.6<br />
50.1<br />
42.0<br />
41.4<br />
39.2<br />
69.0<br />
57.3<br />
56.6<br />
53.8<br />
103.3<br />
85.0<br />
84.0<br />
80.4<br />
130.3<br />
106.5<br />
105.4<br />
101.2<br />
9.0 0.0<br />
0.5<br />
1.0<br />
4.5<br />
20.9<br />
16.9<br />
16.9<br />
16.2<br />
30.0<br />
26.3<br />
25.9<br />
23.8<br />
38,4<br />
33.4<br />
33.0<br />
30.4<br />
55.0<br />
47.5<br />
46.9<br />
43.4<br />
76.2<br />
65.2<br />
64.5<br />
60.0<br />
115.3<br />
97.5<br />
96.5<br />
90.4<br />
146.0<br />
122.7<br />
121.5<br />
114.2<br />
12.0 0.0<br />
0.5<br />
1.0<br />
6.0<br />
20.3<br />
17.3<br />
17.3<br />
16.5<br />
31.4<br />
28.1<br />
27.8<br />
25.0<br />
40.6<br />
36.0<br />
35.4<br />
32.0<br />
58.0<br />
51.2<br />
50.6<br />
46.1<br />
80.8<br />
70.7<br />
70.0<br />
64.0<br />
122.9<br />
106.3<br />
105.3<br />
96.9<br />
156.4<br />
134.2<br />
133.0<br />
122.9<br />
18.0 0.0<br />
0.5<br />
1.0<br />
9.0<br />
-<br />
-<br />
-<br />
-<br />
33.0<br />
-<br />
-<br />
-<br />
42.6<br />
37.3<br />
36.6<br />
-<br />
61.6<br />
55.9<br />
55.5<br />
-<br />
86.4<br />
77.7<br />
77.1<br />
68.7<br />
132.5<br />
117.9<br />
117.0<br />
105.1<br />
169.3<br />
149.7<br />
148.6<br />
134.1<br />
24.0 0.0<br />
0.5<br />
1.0<br />
12,0<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
89.6<br />
82.1<br />
81.5<br />
-<br />
138.0<br />
125.3<br />
124.4<br />
-<br />
177.0<br />
159.7<br />
158.6<br />
140.7<br />
30.0 0.0 - - - - - 141.8 182.1<br />
0.5 - - - - - 130.5 166.7<br />
1.0 - - - - - 129.7 165.7<br />
6
Bijlage 2: Constructiedetails<br />
Figuur 1<br />
Montage paspijp<br />
sectie A<br />
muurbeugel (GKL)<br />
De paspijp (schuifpijp) wordt gebruikt om een willekeurige restmaat tussen 100 en<br />
300 mm te overbruggen. De paspijp laten schuiven over sectie A. Na montage de<br />
paspijp borgen door de slangklem vast te draaien.<br />
7<br />
werkende<br />
lengte<br />
muurbeugel (GKL)<br />
paspijp (GPP)
Figuur 2<br />
Dakdoorvoer pannendak<br />
trekkende kap (GK)<br />
<strong>Metaloterm</strong> AG<br />
elementen<br />
lodenslabpan (GSL) of<br />
verstelbare kunstofpan<br />
trekkende kap (GK)<br />
muurbeugel (GKL)<br />
25 mm<br />
Bij geïsoleerde daken ter plaatse de schuimisolatie verwijderen. De brandwerende<br />
omkokering doortrekken tot boven de onbegaanbare vliering.<br />
8<br />
Zie figuur 7, 8, 8a<br />
onbegaanbare<br />
vliering<br />
brandwerende omkokering
Figuur 3<br />
Dakdoorvoer pannendak<br />
trekkende kap (GK)<br />
lodenslabpan (GSL)<br />
Zie figuur 7, 8, 8a<br />
muurbeugel (GKL)<br />
begaanbare vliering<br />
Bij geïsoleerde daken ter plaatse de schuimisolatie verwijderen. De brandwerende<br />
omkokering doortrekken tot door het dakbeschot omdat de zolderverdieping begaanbaar<br />
is.<br />
9<br />
<strong>Metaloterm</strong>-AG<br />
elementen<br />
stormkraag (GS)<br />
25 mm<br />
brandwerende omkokering
Figuur 4<br />
Dakdoorvoer platdak<br />
trekkende kap (GK)<br />
<strong>Metaloterm</strong> AG<br />
elementen<br />
stormkraag (GS)<br />
dakplaat platdak (GDP)<br />
platdak<br />
isolatie 50 mm (o.a. steenwol)<br />
onbrandbaarA1<br />
muurbeugel (GKL)<br />
brandwerende<br />
omkokering<br />
Het gat in de afdekplaat van de bitumen heeft dezelfde diameter als de bovenkant<br />
van de conus. Zo ontstaat na het afplakken de gewenste opstaande rand tegen de<br />
conus.<br />
10<br />
zie figuur 7, 8, 8a<br />
25 mm
Figuur 5<br />
Doorvoering onbrandbare vloer; WBDBO: < 20 min.<br />
<strong>Metaloterm</strong>-AG<br />
elementen<br />
muurbeugel (GKL)<br />
onbrandbare vloer<br />
brandwerende siliconenkit<br />
(o.a. Promaseal S)<br />
11<br />
D uitw. + 20 mm<br />
onbrandbaar<br />
isolatiemateriaal<br />
(o.a. steenwol<br />
Klasse A1)
Figuur 5a<br />
Doorvoering onbrandbare vloer; WBDBO: < 60 min.<br />
<strong>Metaloterm</strong>-AG<br />
elementen<br />
muurbeugel (GKL)<br />
onbrandbare vloer<br />
brandwerende siliconenkit<br />
(o.a. Promaseal S)<br />
12<br />
D uitw. + 20 mm<br />
25 mm<br />
onbrandbaar<br />
isolatiemateriaal<br />
(o.a. steenwol<br />
Klasse A1)
Figuur 6<br />
Doorvoering brandbare vloer: WBDBO: < 60 min.<br />
brandwerende<br />
omkokering<br />
13<br />
<strong>Metaloterm</strong>-AG<br />
elementen<br />
brandbare vloer<br />
isolatie (o.a. steenwol)<br />
onbrandbaar A1<br />
muurbeugel (GKL)
Figuur 6a<br />
Doorvoering brandbare vloer: WBDBO < 20 min.<br />
14<br />
<strong>Metaloterm</strong>-AG<br />
elementen<br />
afdekking met onbrandbare<br />
plaat 10 mm.<br />
o.a. Promatect-H<br />
brandbare vloer<br />
isolatie<br />
(o.a. steenwol)<br />
onbrandbaar A1<br />
muurbeugel (GKL)
Figuur 7<br />
Bevestiging <strong>Metaloterm</strong>-AG<br />
B<br />
A<br />
A<br />
A<br />
ø mm A B<br />
130 2 1,5<br />
150 2 1,5<br />
180 2 1,5<br />
200 2 1,5<br />
Maten in meters<br />
NB. Bij een totale bouwhoogte > 20 meter dient een muurondersteuning toegepast<br />
te worden.<br />
15<br />
B<br />
A
Figuur 8<br />
Belendende<br />
bebouwing<br />
Belendende<br />
bebouwing<br />
III<br />
IV IV<br />
10˚<br />
< 15 m<br />
16<br />
α > 23˚<br />
III<br />
Uitmonding uitsluitend in gebied I toegestaan met trekkende kap (GK)<br />
Uitmonding in gebied I & II toegestaan met trekkende kap (GK)<br />
Uitmonding uitsluitend in gebied I toegestaan met trekkende kap (GK)<br />
> 15 m<br />
10˚<br />
III<br />
10˚<br />
III<br />
IV<br />
I<br />
II<br />
α > 23˚<br />
Uitmonding in gebied I & II toegestaan met trekkende kap (GK)<br />
I<br />
0.5 m<br />
Uitmonding uitsluitend in gebied l toegestaan met trekkende kap (GK)<br />
I
Figuur 8a<br />
Gebied I uitmonding met trekkende kap (GK)<br />
Gebied III uitmonding niet toegestaan<br />
I<br />
III<br />
lijn volgens<br />
formule<br />
III<br />
0.5 m<br />
schuin dak<br />
dakhelling<br />
α < 23˚<br />
I<br />
0.5 m<br />
0.8 m<br />
schuindak<br />
dakhelling<br />
α > 23˚<br />
Berekening van de uitmondingshoogte indien<br />
de schoorsteen niet binnen 0.8 m uit de nok<br />
door het dakvlak komt.<br />
H = (0.5 + 0.16x(α-23)xa<br />
H is de hoogte van de uitmonding ten<br />
opzichte van het dakvlak (in m)<br />
α is de dakhelling in °<br />
a is de horizontale afstand tussen het hart<br />
van de uitmonding en de nok (in m)<br />
17<br />
0.5 m<br />
plat dak<br />
I<br />
III
Figuur 8b<br />
∆H (in mtr.)<br />
a belasting 10 kW<br />
b belasting 20 kW<br />
c belasting 30 kW<br />
d belasting 40 kW<br />
e belasting 50 kW<br />
Uitmondingen (hinder):<br />
Bovenstaande grafiek geldt voor de meest voorkomende situaties volgens NEN<br />
2757; situatie 1, 6, 8, en 9 zoals weergegeven op de volgende pagina. Deze situaties<br />
gelden voor een atmosferisch gestookt toestel waarvan de afvoer in onderdruk<br />
is. De lengte “L” kan berekend worden middels de hierna volgende formule:<br />
f. =<br />
2.50<br />
2.25<br />
2.00<br />
1.75<br />
1.50<br />
1.25<br />
1.00<br />
0.75<br />
0.50<br />
0.25<br />
a<br />
b<br />
√belasting<br />
c 1 . L + c 2 . ∆H<br />
c<br />
d e<br />
1.00 2.00 3.00 4.00 5.00<br />
L (mtr.).<br />
Waarin:<br />
L is de verbindingslijn tussen een niet afsluitbare ventilatieluchttoevoer of een<br />
verbrandingsluchttoevoer en de rookgasuitmonding.<br />
∆H is het hoogteverschil in meter tussen de niet afsluitbare ventilatieluchttoevoer<br />
of een verbrandingsluchttoevoer en de rookgasuitmonding.<br />
f is de factor welke maximaal 0.01 mag bedragen<br />
c1 is een correctie factor welke in de hier geldige situatie 163 bedraagt<br />
c2 is een correctie factor welke in de hier geldige situatie 325 bedraagt<br />
18
Figuur 8c<br />
D<br />
D<br />
A<br />
D<br />
A<br />
D<br />
75˚ >75˚<br />
G G G G<br />
T<br />
T<br />
>23˚<br />
A<br />
G A<br />
T<br />
>23˚ >23˚ >75˚<br />
D D D G D<br />
A<br />
T<br />
T<br />
A<br />
T<br />
T<br />
A<br />
A<br />
A A<br />
Situatie 1<br />
>23˚<br />
D D D D G D Situatie 8<br />
G/D A G/D G/D A G/D G/D A G/D<br />
T<br />
A<br />
D<br />
D<br />
∆H<br />
A<br />
A<br />
>23˚<br />
T<br />
>23˚<br />
T<br />
D<br />
23˚ >23˚<br />
T<br />
D<br />
h<br />
T<br />
∆H<br />
A<br />
D<br />
>23˚<br />
>75˚<br />
G is de gevel<br />
D is het dak<br />
T is de toevoer<br />
A is de afvoer<br />
∆HH<br />
is de verticale<br />
afstand tussen<br />
afvoer- en<br />
toevoeropening.<br />
>23˚<br />
Situatie 6<br />
Situatie 9
Figuur 9<br />
Verbindingsleidingen <strong>Metaloterm</strong>-AG<br />
GB 90<br />
SITUATIE B<br />
20<br />
SITUATIE A
Figuur 10<br />
Bij dakdoorvoeren (dakplaten en lodenslabpan) wordt de stormkraag (GS) gebruikt<br />
om de kier tussen de schoorsteensectie en de conus van de dakplaat of lodenslab<br />
inregenvrij te maken.<br />
Schuif hiertoe de stormkraag om de schoorsteensectie welke door de dakplaat of<br />
lodenslab is gevoerd, tot deze horizontaal op de opstand rust.<br />
Zorg dat de sectie ter plaatse vetvrij is.<br />
Teken rondom en langs de bovenzijde van de stormkraag de sectie af en schuif de<br />
stormkraag omhoog.<br />
Breng dan een rups kit op de aftekenlijn aan. Duw daarna de stormkraag in de kit en<br />
draai vervolgens de slangklem op de stormkraag aan. De kit dient voor het grootste<br />
deel aan de onderkant van de stormkraag te komen.<br />
21<br />
<strong>Metaloterm</strong>-AG<br />
element<br />
kitrups<br />
conus van<br />
de dakplaat<br />
stormkraag (GS)
Montage handleiding METALOTERM AG<br />
Systeembeschrijving<br />
METALOTERM AG is een modulair dubbelwandig gasafvoersysteem.<br />
De kenmerken van dit systeem zijn:<br />
- aluminium binnenmantel<br />
- thermisch verzinkte buitenmantel<br />
- t/m ø 200 mm voldoet aan KOMO QA-keur<br />
- “klik” sluiting<br />
- dikte binnenwand 0,3 mm in ø 90 t/m 150 mm, 0,4 mm in ø 180 en 200 mm,<br />
0,5 mm in ø 250 t/m 600 mm.<br />
- dikte buitenwand 0,4 mm in ø 90 mm, 0,5 mm in ø 100 t/m 600 mm<br />
Het <strong>Metaloterm</strong> AG systeem is verkrijgbaar in de inwendige diameters (in mm):<br />
90, 100, 110, 130, 150, 180, 200, 250, 300, 350, 400, 450, 500, 600.<br />
Toepassingsgebied<br />
<strong>Metaloterm</strong> AG systeem is geschikt als rookgasafvoersysteem voor gasgestookte<br />
toestellen zonder ventilator, met een schoorsteenverlies van ≥ 17 %, ook wel atmosferisch<br />
gestookte toestellen genoemd. Tevens is dit systeem geschikt als luchttoevoer-<br />
en luchtafvoersysteem. Het AG systeem functioneert alleen in onderdruk. De<br />
maximale rookgastemperatuur is 250°C (zowel continu als incidenteel).<br />
Overige toepassingen in overleg met de fabrikant.<br />
Installatievoorschriften<br />
Het rookgasafvoersysteem moet opgebouwd worden volgens de nationale regelgeving<br />
en de voorschriften van de fabrikant, zoals aangegeven in de documentatie en<br />
het installatievoorschrift AG. Beide worden op aanvraag kosteloos toegezonden.<br />
Montage<br />
Controleer alle onderdelen op eventuele beschadigingen. Het gasafvoersysteem van<br />
onderaf installeren, dus vanaf het toestel richting de uitmonding. Altijd naar binnen<br />
afwaterend monteren. De onderkant van de elementen is herkenbaar aan de rondom<br />
aangebrachte ’vergrendelingsnokjes’. (zie fig. 1)<br />
De montage geschiedt door de elementen in elkaar te schuiven tot de buitenwand<br />
aansluit, d.w.z. dat de nokjes vergrendelen en de ‘klik’sluiting tot stand is gekomen.<br />
(zie fig. 2). Bij montage moet een minimum afstand van tenminste 25 mm tot brandbare<br />
materialen in acht worden genomen. Indien mogelijk het systeem in één rechte<br />
lijn omhoog en door het dak laten lopen. AIs dit niet mogelijk is, kunnen bochten<br />
(code GB 45 en/of GB 90) toegepast worden. Het systeem moet ondersteund worden<br />
op regelmatige afstanden. Ondersteuning vindt plaats door middel van het<br />
gebruik van muurbevestigingsbeugels (code GKL). Deze moeten ook toegepast wor-<br />
22<br />
GASTEC G 11/97
den direct voor en na bochten. Maximum afstand tussen deze beugels is 2 meter.<br />
Eerst de beugel(s) bevestigen, daarna de elementen monteren en vastklemmen in de<br />
beugels.<br />
Om optische redenen verdient het aanbeveling om de naden, indien mogelijk, aan de<br />
achterzijde en in elkaars verlengde te plaatsen.<br />
Let op!<br />
De elementen mogen niet ingekort worden. De ‘klik’ sluiting van de elementen komt<br />
dan niet tot stand. Gebruik voor afwijkende lengtes de paspijp (code GPP).<br />
figuur 1<br />
figuur 2<br />
23
© 1997 ONTOP METALOTERM<br />
Niets uit deze uitgave mag worden vermenigvuldigd en/of openbaar gemaakt door<br />
middel van druk, fotokopie, microfilm of op welke andere wijze dan ook, zonder voorafgaande<br />
schriftelijke toestemming van ONTOP B.V.<br />
METALOTERM is een gedeponeerde handelsnaam.
Ontop B.V.<br />
Postbus 135, 4330 AC Middelburg<br />
Oude Veerseweg 23, 4332 SH Middelburg<br />
Telefoon: +31 (0)118 689 900<br />
Fax: +31 (0)118 689 999<br />
E-mail: info.nl@metaloterm.com<br />
Ontop Abgastechnik GmbH<br />
Postfach 1340, 51657 Wiehl<br />
Albert-Einstein-Straße 8, 51674 Wiehl<br />
Telefon (0 22 61) 7 08 –0<br />