NO0618<br />

01.13<br />

<strong>TLG</strong>-LØV LØV-R<br />

Sirkulær tilluftsventil<br />

• Designbeskyttet LØV-perforering<br />

• Tåler stor undertemperatur<br />

• Justerbar spaltehøyde<br />

• Lavtbyggende<br />

• Dokumentert med Luna plenumskammer<br />

• Ecoson dempingsmateriale i kammer<br />

<strong>TROX</strong> <strong>Auranor</strong> <strong>Norge</strong> AS<br />

Postboks 100<br />

2712 Brandbu<br />

Telefon +47 61 31 35 00<br />

Telefaks +47 61 31 35 10<br />

e-post: firmapost@auranor.no<br />

www.trox.no


<strong>TLG</strong>-LØV<br />

anvendelse<br />

<strong>TLG</strong>-LØV er en sirkulær tilluftsventil for mont<strong>as</strong>je i f<strong>as</strong>t himling.<br />

<strong>TLG</strong>-LØV har meget god induksjon og egner seg for både konstant og<br />

variabel luftmengde.<br />

Utførelse<br />

<strong>TLG</strong>-LØV har frontplate med LØV-perforering og justerbar spaltehøyde.<br />

MATERIALE OG OVERFLATEBEHANDLING<br />

Ventilen er produsert i stål og har EPDM gummipakning på anslutningen.<br />

Hele ventilen er innvendig og utvendig lakkert i RAL 9010. Andre<br />

farger leveres på forespørsel.<br />

MÅL OG VEKT, <strong>TLG</strong>-løv<br />

Dim. A B J T Utsp. Vekt<br />

mål ventil<br />

[kg]<br />

100 209 99 25 34-45 105 0,7<br />

125 238 124 33 34-45 130 0,9<br />

160 279 159 35 36-50 165 1,1<br />

200 334 199 35 38-52 205 1,4<br />

250 419 249 83 52-72 375 2,1<br />

315 525 314 93 53-73 470 3,0<br />

Tabell 2<br />

Hurtigvalg<br />

<strong>TLG</strong>-LØV<br />

[m³/h]<br />

Dim. 25 dB(A) 30 dB(A) 35 dB(A)<br />

100 87 104 123<br />

125 144 167 194<br />

160 238 273 312<br />

200 328 378 436<br />

250 609 707 820<br />

315 897 1046 1220<br />

Tabell 1, viser luftmengder ved oppgitt lydeffektnivå. Maksimal spaltehøyde<br />

og ventil montert direkte i rett kanal.<br />

BESTILLINGSKODE: <strong>TLG</strong>-LØV /Luna s.2<br />

BestillingsKODe, <strong>TLG</strong>-LØV<br />

<strong>TLG</strong>-LØV-0-125-0<br />

Produkt:<br />

S = Sentrert strålemønster<br />

E = Enveis LØV mønster<br />

Dimensjon: Ø100 - Ø315<br />

Eksempel:<br />

<strong>TLG</strong>-LØV-0-125-0<br />

Forklaring:<br />

<strong>TLG</strong>-LØV dim. Ø125.<br />

q 594<br />

SL = Spesiallakk<br />

Figur 1<br />

<strong>TLG</strong>-LØV 100-200<br />

OB<br />

OA<br />

<strong>TLG</strong>-LØV 250 og 315<br />

OB<br />

OA<br />

T J<br />

J<br />

T<br />

BestillingsKODe, Luna<br />

Produkt:<br />

UI = Utløp montert inn,<br />

lav byggehøyde<br />

I = Isolert<br />

Luna-0-0-125-125<br />

Dim. utløp: Ø100 - Ø315<br />

Dim. innløp: Ø100 - Ø315<br />

Eksempel:<br />

Luna-0-0125-125<br />

Forklaring:<br />

Luna med innløp Ø125 og utløp Ø125.<br />

2


<strong>TLG</strong>-LØV med Luna plenumskammer<br />

anvendelse<br />

Luna plenumskammer anbefales benyttet for å gi bedre lyddemping,<br />

samt regulerings- og målemulighet. Luna er et rektangulært kammer<br />

med demonterbart spjeld som gir tilgang til anslutningskanal. Spjeldet<br />

låses i ønsket posisjon.<br />

Utførelse<br />

Plenumskammeret Luna har spjeld og måleuttak for innregulering.<br />

Kammeret er isolert med Ecoson og kan leveres med én eller<br />

to dimensjonsforandringer mellom inn- og utløp. Kammeret kan også<br />

leveres med utvendig kondensisolering [I].<br />

Lavbyggende utførelse [UI] er også tilgjengelig, denne utførelsen<br />

gir en kap<strong>as</strong>itetsreduksjon på ca. 20 %. Avstanden mellom ventil<br />

og kammer kan økes med inntil 35 cm uten at vaier og måleslange<br />

må forlenges.<br />

MATERIALE OG OVERFLATEBEHANDLING<br />

Luna leveres i galvanisert utførelse, innvendig isolert i fire sider med<br />

Ecoson fiberfri isol<strong>as</strong>jon.<br />

Anslutningen har EPDM gummipakning.<br />

Hurtigvalg<br />

MÅL OG VEKT, luna<br />

Dim. D DA B H H1 H2 L L1 L2 Vekt<br />

Luna<br />

[kg]<br />

100-100 99 102 220 122 167 45 325 295 133 2,3<br />

100-125 99 127 220 122 167 45 325 295 133 2,3<br />

100-160 99 162 220 122 167 45 360 310 150 2,4<br />

125-125 124 127 250 147 192 45 360 335 150 2,4<br />

125-160 124 162 250 147 192 45 360 335 150 2,9<br />

125-200 124 202 250 147 192 45 400 355 170 3,1<br />

160-160 159 162 340 182 227 45 400 390 170 4,1<br />

160-200 159 202 340 182 227 45 400 390 170 4,2<br />

160-250 159 252 340 182 272 90 452 415 198 4,6<br />

200-200 199 202 380 222 267 45 452 460 198 5,7<br />

200-250 199 252 380 222 312 90 452 460 198 5,7<br />

200-315 199 317 380 222 312 90 515 485 228 6,1<br />

250-250 249 252 390 272 362 90 515 535 228 7,4<br />

250-315 249 317 390 272 362 90 515 535 228 7,4<br />

315-315 314 317 500 337 427 90 600 655 260 11<br />

Tabell 4<br />

<strong>TLG</strong>-LØV Luna [m³/h]<br />

Dim. Dim. 25 dB(A) 30 dB(A) 35 dB(A)<br />

100 100-100 67 81 97<br />

125 100-125 77 103 133<br />

125-125 94 112 133<br />

160 125-160 94 130 169<br />

160-160 148 176 216<br />

200 160-200 162 198 245<br />

200-200 216 252 295<br />

250 200-250 245 295 389<br />

250-250 349 403 493<br />

315 250-315 331 421 533<br />

315-315 547 626 720<br />

BESTILLINGSKODE; <strong>TLG</strong>-LØV med Luna s.3<br />

Tabell 3, tabellen viser luftmengde ved oppgitt lydeffektnivå og<br />

50 Pa totaltrykk.<br />

BestillingsKODe,<strong>TLG</strong>-LØV med Luna<br />

<strong>TLG</strong>-LØV-0-L-SL<br />

Produkt:<br />

S = Sentrert strålemønster<br />

E = Enveis LØV mønster<br />

SL = Spesiallakk<br />

Figur 2<br />

L-0-0-125-160<br />

Produkt: L = Luna<br />

UI = Utløp montert inn,<br />

lav byggehøyde<br />

I = Isolert<br />

Dim. utløp/ventil: Ø100 - Ø315<br />

Dim. innløp: Ø100 - Ø315<br />

Eksempel:<br />

<strong>TLG</strong>-LØV-0-L-0-0-125-160-SL<br />

Forklaring:<br />

<strong>TLG</strong>-LØV ventil og Luna plenumskammer innløp Ø125 og utløp/ventil dim. Ø160,<br />

lakkert i spesialfarge RAL 9006*<br />

*Fargekode må angis.<br />

3


<strong>TLG</strong>-LØV<br />

Akustisk dokument<strong>as</strong>jon<br />

I diagrammene er det oppgitt summert A-veid lydeffektnivå fra ventil,<br />

L WA<br />

. Korreksjonsfaktorene i tabell 6, side 8, benyttes for å beregne<br />

avgitt frekvensfordelt lydeffektnivå, L W<br />

= L WA<br />

+ KO. Lydtrykknivå i et<br />

rom med absorpsjon tilsvarende 10m² Sabine vil være 4 dB lavere enn<br />

avgitt lydeffektnivå.<br />

Diagrammene gjelder ved maksimal spaltehøyde.<br />

Eksempel:<br />

<strong>TLG</strong>-LØV med Luna 125-125, ønsket luftmengde 35 l/s.<br />

Av diagram 4 finner vi at L WA<br />

= 31 dB(A) ved åpent spjeld og<br />

20 Pa totaltrykktap. Vi ønsker å finne følgende data:<br />

a) avgitt lydeffektnivå i 250 Hz<br />

b) A-veid lydtrykknivå i et kontor<br />

c) A-veid lydtrykknivå i et kontor ved 50 Pa totaltrykktap, (dvs. 30 Pa<br />

struping over enhetens spjeld.)<br />

a) Korreksjonsfaktoren er 2 dB. Avgitt lydeffektnivå i 250 Hz<br />

blir da: L W<br />

= L WA<br />

+ KO = 31 + (2) = 33 dB<br />

b) Hvis vi forutsetter romabsorpsjon tilsvarende 10m² Sabine,<br />

blir A-veid lydtrykknivå: 31 – 4 = 27 dB(A)<br />

c) Ved å følge linjen for 35 l/s i diagrammet opp til 50 Pa,<br />

av leses 33 dB(A) = økning på 2 dB, det vil si at A-veid<br />

lydtrykknivå blir 29 dB(A)<br />

Dimensjoneringsdiagram<br />

∆p t<br />

[Pa]<br />

150<br />

2 3 4 5 [m/s]<br />

∆p t [Pa]<br />

150<br />

3 4 5 6<br />

[m/s]<br />

100<br />

100<br />

40<br />

75<br />

40<br />

75<br />

35<br />

35<br />

50<br />

50<br />

30<br />

40<br />

30<br />

40<br />

30<br />

25<br />

30<br />

25<br />

20<br />

20<br />

16 18 20 25 30 35<br />

[l/s]<br />

20 25 30 35 40 45<br />

[l/s]<br />

60 70 80 90 100 120 140 [m 3 /h]<br />

60 70 80 100 120 140 160<br />

[m 3 /h]<br />

Diagram 1, <strong>TLG</strong>-LØV m/Luna 100-100<br />

Diagram 2, <strong>TLG</strong>-LØV m/Luna 100-125<br />

∆p t<br />

[Pa]<br />

150<br />

3 4 5 6 7<br />

[m/s]<br />

∆p t [Pa]<br />

150<br />

2 3 4<br />

[m/s]<br />

100<br />

40<br />

100<br />

40<br />

75<br />

75<br />

35<br />

35<br />

50<br />

40<br />

30<br />

50<br />

40<br />

30<br />

30<br />

25<br />

30<br />

25<br />

20<br />

20<br />

25 30 35 40 45 50 55<br />

[l/s]<br />

25 30 35 40 45 50 55<br />

[l/s]<br />

80 100 120 140 160 180 200<br />

[m 3 /h]<br />

80 100 120 140 160 180 200<br />

[m 3 /h]<br />

Diagram 3, <strong>TLG</strong>-LØV m/Luna 100-160<br />

Diagram 4, <strong>TLG</strong>-LØV m/Luna 125-125<br />

4


<strong>TLG</strong>-LØV<br />

med Luna plenumskammer<br />

∆p t [Pa]<br />

150<br />

2 3 4 5<br />

[m/s]<br />

∆p t<br />

[Pa]<br />

150<br />

2 3 4 5 6<br />

[m/s]<br />

100<br />

75<br />

40<br />

100<br />

75<br />

40<br />

50<br />

40<br />

30<br />

35<br />

50<br />

40<br />

30<br />

35<br />

30<br />

25<br />

30<br />

25<br />

20<br />

20<br />

25 30 35 40 45 50 60 [l/s]<br />

25 30 35 40 45 50 60 70<br />

80 100 120 140 160 180 200<br />

[m 3 /h]<br />

80 100 150 200 250<br />

Diagram 5, <strong>TLG</strong>-LØV m/Luna 125-160 Diagram 6, <strong>TLG</strong>-LØV m/Luna 125-200<br />

[l/s]<br />

[m 3 /h]<br />

∆p t<br />

[Pa]<br />

150<br />

2 3 4<br />

[m/s]<br />

∆p t<br />

[Pa]<br />

150<br />

2,5 3 4<br />

[m/s]<br />

100<br />

100<br />

75<br />

40<br />

75<br />

40<br />

50<br />

40<br />

30<br />

25<br />

30<br />

35<br />

50<br />

40<br />

30<br />

25<br />

30<br />

35<br />

20<br />

20<br />

40 45 50 55 60 65 70 80 [l/s]<br />

45 50 55 60 70 80 90 [l/s]<br />

140 160 180 200 250 300<br />

[m 3 /h]<br />

160 180 200 250 300 350 [m 3 /h]<br />

Diagram 7, <strong>TLG</strong>-LØVm/Luna 160-160 Diagram 8, <strong>TLG</strong>-LØV m/Luna 160-200<br />

∆p t [Pa]<br />

150<br />

3 4 5 6<br />

[m/s]<br />

∆p t [Pa]<br />

150<br />

2 2,5 3<br />

[m/s]<br />

100<br />

100<br />

75<br />

40<br />

75<br />

40<br />

50<br />

40<br />

30<br />

30<br />

35<br />

50<br />

40<br />

30<br />

30<br />

35<br />

25<br />

25<br />

20<br />

20<br />

50 60 70 80 90 100 120<br />

[l/s]<br />

60 70 80 90 100 110<br />

[l/s]<br />

150 200 250 300 350 400 450<br />

[m 3 /h]<br />

200 250 300 350 400<br />

[m 3 /h]<br />

Diagram 9, <strong>TLG</strong>-LØV m/Luna 160-250 Diagram 10, <strong>TLG</strong>-LØV m/Luna 200-200<br />

5


<strong>TLG</strong>-LØV<br />

∆p t<br />

[Pa]<br />

150<br />

2 2,5 3 4 5<br />

[m/s]<br />

∆p t [Pa]<br />

150<br />

2 2,5 3 4 5<br />

[m/s]<br />

100<br />

100<br />

75<br />

40<br />

75<br />

40<br />

35<br />

50<br />

40<br />

30<br />

50<br />

40<br />

35<br />

30<br />

25<br />

30<br />

30<br />

20<br />

20<br />

25<br />

60 70 80 100 120 140 160<br />

[l/s]<br />

60 70 80 100 120 140 160<br />

[l/s]<br />

200 300 400 500 600<br />

[m 3 /h]<br />

200 300 400 500 600<br />

[m 3 /h]<br />

Diagram 11, <strong>TLG</strong>-LØV m/Luna 200-250<br />

Diagram 12, <strong>TLG</strong>-LØV m/Luna 200-315<br />

∆p t<br />

[Pa]<br />

150<br />

2 2,5 3 4 [m/s]<br />

∆p t [Pa]<br />

150<br />

2 2,5 3 4<br />

[m/s]<br />

100<br />

100<br />

75<br />

40<br />

75<br />

40<br />

50<br />

35<br />

50<br />

35<br />

40<br />

30<br />

40<br />

30<br />

30<br />

25<br />

30<br />

25<br />

20<br />

20<br />

100 120 140 160 180<br />

[l/s]<br />

100 120 140 160 180 200 220<br />

[l/s]<br />

300 400 500 600 700 [m 3 /h]<br />

300 400 500 600 700 800<br />

Diagram 13, <strong>TLG</strong>-LØV m/Luna 250-250 Diagram 14, <strong>TLG</strong>-LØV m/Luna 250-315<br />

[m 3 /h]<br />

∆p t [Pa]<br />

150<br />

2 2,5 3,5 m/s<br />

100<br />

75<br />

40<br />

50<br />

40<br />

35<br />

30<br />

30<br />

20<br />

25<br />

140 160 180 200 220 240 260<br />

500 600 700 800 900<br />

Diagram 15, <strong>TLG</strong>-LØV m/Luna 315-315<br />

l/s<br />

m 3 /h<br />

6


<strong>TLG</strong>-LØV<br />

∆p t [Pa]<br />

50<br />

Ø100<br />

Ø125<br />

Ø160<br />

Ø200<br />

Ø250<br />

∆p t [Pa]<br />

50<br />

Ø100<br />

Ø125<br />

Ø160<br />

Ø200<br />

Ø250<br />

40<br />

30<br />

Ø315<br />

40<br />

30<br />

Ø315<br />

20<br />

40<br />

20<br />

40<br />

15<br />

35<br />

15<br />

35<br />

10<br />

9<br />

8<br />

7<br />

25<br />

30<br />

10<br />

9<br />

8<br />

7<br />

25<br />

30<br />

6<br />

6<br />

5<br />

30 40 50 60 70 80 100 150 200 250 300 400<br />

[l/s]<br />

5<br />

30 40 50 60 80 100 150 200 250 300 350 [l/s]<br />

100 200 300 400 500 600 800 1000 1500 [m 3 /h]<br />

100 150 200 300 400 500 600 800 1000 [m 3 /h]<br />

Diagram 16, <strong>TLG</strong>-LØV i kanalende<br />

Diagram 17, <strong>TLG</strong>-LØV i 90° bend<br />

Statisk lyddemping inkl. enderefleksjon, <strong>TLG</strong>-LØV med Luna<br />

<strong>TLG</strong>-LØV Luna Demping [dB]<br />

Dim. Dim. 63 125 250 500 1k 2k 4k 8k<br />

100 100-100 25 16 17 20 22 20 16 12<br />

125 100-125 26 12 14 18 20 19 14 17<br />

160 100-160 25 11 13 16 18 19 14 17<br />

125 125-125 24 16 16 20 22 17 13 19<br />

160 125-160 24 11 10 16 19 15 11 17<br />

200 125-200 25 11 9 15 18 15 10 15<br />

160 160-160 20 13 15 16 12 10 11 10<br />

200 160-200 17 9 10 16 18 11 13 17<br />

250 160-250 19 11 12 15 17 10 11 11<br />

200 200-200 18 12 15 18 18 12 16 18<br />

250 200-250 17 12 14 16 16 10 14 16<br />

315 200-315 18 11 13 13 15 9 12 15<br />

250 250-250 15 10 14 15 15 11 13 16<br />

315 250-315 17 11 13 15 14 10 12 14<br />

315-315 12 9 14 16 11 11 12 14<br />

Tabell 5<br />

7


<strong>TLG</strong>-LØV<br />

Korreksjonsfaktor [KO], <strong>TLG</strong>-LØV med Luna<br />

KO [dB]<br />

<strong>TLG</strong>-LØV Luna Stengt spjeld Åpent spjeld<br />

Dim. Dim. 63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k<br />

100 100-100 -4 4 0 -5 -5 -7 -13 -20 -4 1 -2 -6 -5 -6 -14 -24<br />

125 100-125 -2 6 2 -5 -7 -8 -10 -15 -1 6 1 -5 -5 -8 -17 -23<br />

160 100-160 -1 3 4 -5 -8 -9 -10 -13 -2 3 3 -4 -6 -7 -18 -22<br />

125 125-125 1 3 1 -5 -6 -9 -9 -11 2 4 2 -5 -5 -8 -17 -22<br />

160 125-160 -9 0 0 -7 -8 -8 -7 -10 -6 1 2 -5 -6 -7 -16 -24<br />

200 125-200 0 0 -1 -6 -9 -9 -6 -8 3 3 2 -4 -5 -8 -17 -21<br />

160 160-160 2 3 0 -5 -6 -7 -11 -12 2 3 1 -4 -5 -9 -18 -19<br />

200 160-200 0 3 2 -6 -8 -7 -9 -10 4 3 2 -4 -5 -9 -19 -20<br />

250 160-250 0 0 -2 -8 -10 -6 -7 -9 1 1 1 -5 -4 -8 -19 -21<br />

200 200-200 3 4 -1 -5 -5 -7 -14 -15 2 3 -2 -6 -4 -6 -17 -24<br />

250 200-250 -1 1 -3 -7 -7 -6 -9 -10 1 1 -1 -3 -4 -9 -20 -22<br />

315 200-315 -2 -1 -4 -8 -9 -5 -7 -10 2 -1 -4 -6 -3 -8 -19 -26<br />

250 250-250 1 3 -3 -4 -5 -8 -10 -11 2 4 -1 -3 -4 -9 -19 -22<br />

315 250-315 -2 -1 -4 -8 -9 -5 -7 -10 1 -1 -4 -6 -3 -8 -19 -26<br />

315-315 -4 -4 -6 -2 -2 -11 -21 -25 1 1 -4 -4 -4 -7 -19 -25<br />

Tabell 6<br />

Statisk lyddemping inkl. enderefleksjon for <strong>TLG</strong>-LØV<br />

<strong>TLG</strong>-LØV<br />

Demping [dB]<br />

Dim. 63 125 250 500 1k 2k 4k 8k<br />

100 26 18 13 7 3 2 3 6<br />

125 22 16 11 6 1 0 2 4<br />

160 19 14 11 4 1 0 3 4<br />

200 16 12 7 3 0 0 2 3<br />

250 16 10 5 1 0 0 1 2<br />

315 15 7 4 1 0 0 1 2<br />

Tabell 7<br />

Korreksjonsfaktor [KO], <strong>TLG</strong>-LØV<br />

<strong>TLG</strong>-LØV<br />

KO [dB]<br />

Dim. 63 125 250 500 1k 2k 4k 8k<br />

100 -3 -1 -6 -6 -5 -5 -13 -22<br />

125 -6 -4 -6 -6 -6 -5 -12 -23<br />

160 1 -1 -3 -4 -5 -6 -16 -21<br />

200 0 0 -5 -6 -5 -5 -16 -24<br />

250 0 -5 -5 -4 -3 -7 -20 -21<br />

315 -3 -7 -8 -6 -3 -6 -19 -26<br />

Tabell 8<br />

KASTELENGDE, <strong>TLG</strong>-LØV<br />

Spredningsmønster, <strong>TLG</strong>-LØV<br />

L 0,2 [m]<br />

L 0,3 [m]<br />

12<br />

8,0<br />

10<br />

8<br />

6<br />

5<br />

4<br />

Ø100<br />

Ø125<br />

Ø160<br />

Ø200<br />

Ø250<br />

Ø315<br />

6,7<br />

5,3<br />

4,0<br />

3,3<br />

2,7<br />

3<br />

2,0<br />

2<br />

1,3<br />

30 40 50 60 70 80 100 150 200 [l/s]<br />

100 150 200 250 300 400 500 600 800 [m 3 /h]<br />

Diagram 18, <strong>TLG</strong>-LØV. Figur 3<br />

8


<strong>TLG</strong>-LØV<br />

KASTELENGDE, <strong>TLG</strong>-LØV-S<br />

Det er målt h<strong>as</strong>tigheter på nedadrettet stråle for <strong>TLG</strong>-LØV-S.<br />

Ved isoterme forhold kan diagram 19 benyttes til å finne den vertikale<br />

k<strong>as</strong>telengden.<br />

For overtemperert luft (oppvarming) benyttes diagram 20 og 21 til å<br />

finne vendepunktet til strålen med hhv. 5 eller 10° overtemperert luft i<br />

forhold til romluftens temperatur.<br />

Diagram 19, Isoterm ståle.<br />

Diagram 20, +5° overtemperatur.<br />

Diagram 21, +10° overtemperatur.<br />

9


<strong>TLG</strong>-LØV<br />

Montering<br />

Ved montering i f<strong>as</strong>t tak eller innfelt i himlingsplate festes <strong>TLG</strong>-LØV<br />

ved hjelp av to mont<strong>as</strong>jevinkler som vist i figur 5, eller ventilen skrus<br />

f<strong>as</strong>t i kammerts utløp. Dersom plenumskammer Luna benyttes pendles<br />

dette i opphengsbraketten i bakkant med gjengestag eller bånd (figur 5).<br />

INNREGULERING<br />

Ved innregulering må ventilfronten være påmontert. Måleslange og<br />

reguleringsvaier trekkes ut gjennom spalten på ventilen. Spjeldet låses<br />

med låsemutter på vaieren. K-faktorer for utregning av luftmengde<br />

finnes på merkelappen i ventilen, eller i vår innjusteringsguide på vår<br />

hjemmeside: www.trox.no.<br />

VEDLIKEHOLD<br />

Ventilen rengjøres med en fuktig klut. Ved rensing av kanalnettet<br />

fjernes ventilfronten for å komme til kanalen. Dersom Luna benyttes,<br />

demonteres fordelingsplaten og spjeldet for fri tilgang til kanalen.<br />

MILJØ<br />

Forespørsel vedrørende byggvaredeklar<strong>as</strong>jon kan rettes til en av våre<br />

selgere, eller finnes på vår hjemmeside: www.trox.no<br />

Figur 4, mont<strong>as</strong>je<br />

Figur 5, mont<strong>as</strong>je<br />

<strong>TLG</strong>-LØV er utviklet og produsert av:<br />

Rett til endringer forbeholdes.<br />

www.dmt.no<br />

Hovedkontor:<br />

<strong>TROX</strong> <strong>Auranor</strong> <strong>Norge</strong> AS, Postboks 100, 2712 Brandbu<br />

Telefon: 61 31 35 00 Telefaks: 61 31 35 10 www.trox.no