6 Putting into operation<br />

6.1 Check the spring tension<br />

The spring tension has been set in<br />

the factory and does not usually<br />

need to be altered. (Exception: Variant<br />

doors without lining).<br />

Check the tension by opening the<br />

door about 1 metre and then letting<br />

it fall. It is ideal if the door<br />

stops in this position. The door<br />

does not move up or down into its<br />

end position until gentle pressure is<br />

applied.<br />

However, if the door moves out of<br />

this position on its own either upwards<br />

or downwards, adjust the<br />

springs.<br />

6.2 Adjust the spring tension<br />

Caution!<br />

The springs are under tension<br />

and can spring out in the event<br />

of incorrect use.<br />

– Work with the springs carefully<br />

and carry out this work only<br />

when the door is open and<br />

supported (springs not tensioned).<br />

There is a risk of squashing<br />

when carrying out work on the<br />

springs.<br />

– Wear gloves!<br />

On Variant doors without linings<br />

the springs are set at the factory for<br />

a lining weight of 8 kg/m 2 . On<br />

doors with a width of up to 3 m the<br />

spring packets are not prestressed<br />

and must be adjusted to the actual<br />

lining weight.<br />

Adjust the springs so that they are<br />

the same on both sides<br />

Caution!<br />

Danger of injury by springs<br />

jumping out.<br />

– After setting the spring tension<br />

refit the spring safety<br />

sleeve.<br />

Do not operate the up and over<br />

door without a spring safety sleeve.<br />

6.3 Install safety cover<br />

Caution!<br />

Risk of crush injuries on the lifting<br />

mechanism.<br />

– Do not operate the up and<br />

over door without the safety<br />

cover on the lifting mechanism.<br />

Insert the expanding rivets in the<br />

holes, then press in the rivet arbour<br />

completely.<br />

6.4 Locking/unlocking<br />

Check the setting and adjust it if<br />

necessary.<br />

(A) Rod locking mechanism:<br />

Adjust the locking mechanism so<br />

that there is a gap (around 2 mm)<br />

between the rod and the background.<br />

(B) Cable locking mechanism<br />

(Prominent, Rustico, Elegant):<br />

Prestress the cable slightly. There<br />

must be no gap on the handle.<br />

Adjust the lock so that a gap<br />

(approximately 2 mm) remains between<br />

the lock and the lock box.<br />

(C) Cable locking mechanism<br />

(Variant, Prominent backbone):<br />

Prestress the cable slightly. There<br />

must be no gap on the handle.<br />

Adjust the lock so that a gap<br />

(approximately 2 mm) remains between<br />

the lock and the lock box.<br />