13.07.2015 Views

User Manual - Data Migration - DK - Energinet.dk

User Manual - Data Migration - DK - Energinet.dk

User Manual - Data Migration - DK - Energinet.dk

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Brugermanual – <strong>Data</strong>migreringVersion 1.0.4Dato 13. april 2012Error Code Validation File Type Error Messageas the checksum for quantities in the footerchecksum for quantities in the footer of the file.of the file.DM-113The length of an attribute in the file islonger than the maximum length specifiedin the file definition for the body.ALL_CONNECTION,MASTERDATA, METERDATA,DELETE_CONNECTIONThe length of attribute is longer than the maximumlength specified in the file definition for the body.DM-114DM-115DM-116DM-117DM-119DM-120DM-121The type of an attribute in the file is notconforming to the type specified in the filedefinition for the body.The metering point ID holds 18 digits, thelast digit contains the checksum of thepreceding 17 digits, i.e. sum(odd x 3, evenx 1) mod 10.The start or end time of a meter datarecord is not conform format YYYY-MM-DDTHH:MMZ.The metering point ID in the file has to beunique.The combination of metering point ID andstart time has to be unique.The combination of metering point ID andend time has to be unique.An attribute in the file is mandatory in thefile definition for the body.ALL_CONNECTION,MASTERDATA, METERDATA,DELETE_CONNECTIONThe type of the attribute is different from the type of theof the attribute specified in the file definition for the body.ALL_CONNECTION The metering point ID specified is not a valid GSRN /EAN18 code (wrong checksum).METERDATAALL_CONNECTION,DELETE_CONNECTIONMETERDATAMETERDATAALL_CONNECTION,MASTERDATA, METERDATA,DELETE_CONNECTIONDM-122 There must be files present to process. ALL_CONNECTION,MASTERDATA, METERDATA,DELETE_CONNECTIONDM-123The combination of aDELETE_CONNECTIONDELETE_CONNECTION file and one or moreof the other files is not allowed.DM-201Metering point is imported by the same grid ALL_CONNECTIONoperator as before.DM-202Metering point is imported by another grid ALL_CONNECTIONoperator as well.DM-203Metering point in the MASTERDATA file has MASTERDATAnot been delivered in ALL_CONNECTION fileyet (or has been deleted in the past).DM-205Type of metering point in the MASTERDATA MASTERDATAfile should not be changed.DM-206The occurrence of the new connection state MASTERDATAof a metering point in the MASTERDATA fileshould not be before the occurrences of thealready present connection states in theThe attribute of metering point ID isnot in format YYYY-MM-DDTHH:MMZ.The metering point ID is not unique in the file.The metering point ID and start time isnot unique in the file.The metering point ID and end time is notunique in the file.The attribute is mandatory in the file definition for thebody.*There are no files present for run number and grid area to process.**In a run a combination of a DELETE_CONNECTION file and one or more ofthe other files is not allowed.**Metering point in ALL_CONNECTION has already beendelivered by the same grid operator.Metering point in ALL_CONNECTION has already beendelivered by grid operator .Metering point in the MASTERDATA file has not beendelivered in ALL_CONNECTION file or has been deleted. The records for thismetering point will be rejected.The type of metering point of metering point in the MASTERDATA file must not be changed.The occurrence of the new connection state of meteringpoint in the MASTERDATA file may not be before theoccurrence * of the already present connections states in themigration area.side 50 af 60

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!