13.07.2015 Views

User Manual - Data Migration - DK - Energinet.dk

User Manual - Data Migration - DK - Energinet.dk

User Manual - Data Migration - DK - Energinet.dk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Brugermanual – <strong>Data</strong>migreringVersion 1.0.4Dato 13. april 2012RuleNumberVAL-047VAL-048VAL-049VAL-050VAL-051VAL-052VAL-053VAL-054VAL-055VAL-056VAL-057VAL-058VAL-059Rule Description Attribute Rule Type Explanation10000000..99999999 (if available)The consumer CVR of a metering point isempty if the first consumer party reference orthe second consumer party reference isavailableThe second consumer party name of ametering point consists of maximal 35characters (if available)The second consumer party reference of ametering point has format YYYY-MM-DD (ifavailable)ConsumerCVRFirstConsumerPartyReferenceSecondConsumerPartyNameSecondConsumerPartyReferenceThe second consumer party reference of a SecondConsumerPartyRefemetering point is empty if the consumer CVR is renceavailableConsumerCVRThe estimated annual volume of a meteringpoint is mandatoryThe estimated annual volume of a meteringpoint consists of maximal 18 digitsThe consumer category of a metering pointconsists of maximal 4 digits (if available)The settlement method of a metering point ismandatoryThe settlement method of a metering point hasdomain values E01 (Profiled), E02 (Nonprofiled)The reading characteristics of a metering pointis mandatory for a profiled metering pointThe reading characteristics of a metering pointhas domain values D01 (Automatic), D02(<strong>Manual</strong>)The first scheduled meter reading date of ametering point is mandatory for a profiledmetering pointThe scheduled meter reading date of ametering point has format MMDDEstimatedAnnualVolumeTypeOfMPDependancyOnly one of the three attributes is requiredFormat All characters are allowed, length is restricted to 35FormatDependancyObligationDependancyDate format is '--', so length isrestricted to 10Only one of the three attributes is requiredA metering point cannot be registered in CCR without a valid estimated annual volumeEstimatedAnnualVolume Format Only digits are allowed, length is restricted to 18ConsumerCategory Format Only digits are allowed, length is restricted to 4SettlementMethodTypeOfMPObligationDependancySettlementMethod Domain Only specific domain values are allowedMPReadingCharacteristicsSettlementMethod*ObligationDependancyA metering point cannot be registered in CCR without a valid settlement methodA profiled metering point cannot be registered in CCR without valid readingcharacteristicsMPReadingCharacteristics Domain Only specific domain values are allowedScheduledMeterReadingDate1SettlementMethod*ObligationDependancyA profiled metering point cannot be registered in CCR without any valid scheduledmeter reading dateScheduledMeterReadingDate1…ScheduledMeterReadingDatFormat Date format is '', so length is restricted to 4side 56 af 60

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!