10.07.2015 Views

D GB E DK P Motormodul MZ2 MM2x8A Technische ... - Essmann

D GB E DK P Motormodul MZ2 MM2x8A Technische ... - Essmann

D GB E DK P Motormodul MZ2 MM2x8A Technische ... - Essmann

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Motor Modul <strong>MZ2</strong> <strong>MM2x8A</strong>Terminal assignmentTop terminal row(as a rule the terminal board for the fitter)Numbering the connection terminals follows the same principle for all <strong>MZ2</strong>-modules.(Exception power supply unit NM16A).Module-view:Starts at top left.The numbering is continued at each deeper level, starting at the left.1 2 3. . .<strong>MZ2</strong>Modul. . .4 . . .. . .. . .1 2 3 4<strong>MM2x8A</strong>OKAB5 6 7 81 2 3 45 6 7 8Numbering of the bottom terminal row is continued as per the procedure describedabove at .9 10 11 12. . .. . .9 10 11 12. . .. . .13 14 15 1613 14 15 16. . . . . .Bottom terminal row(as a rule the terminal board for the fitter)ConnectionsMotor circuit APlease see the wiring and terminal plan for the position of the terminals and thewiring with the <strong>MZ2</strong> modules and actuators.brownWarning: Each terminal can be loaded with a maximum of 12 A! The modulemust never be fitted on the top hat rail when the supply is switched on; this will leadto damage to the module and the external actuator circuit monitoring diodes.MblueTerminal 1: Output actuator circuit A (-) (in relation to: direction of movement "Open")Terminal 2: Output actuator circuit A (+) (in relation to: direction of movement "Open")Output “Open”Terminal 3: Monitoring line actuator circuit ATerminal 4: Output “On-display" for actuator circuit A (+24 V against mass).Idle if "Emergency operation".Terminal 9: 24 V supply actuator circuit AAA1 2 3 49 10 11 12Terminal 10: 24 V supply actuator circuit A (internally bridged to terminal 9)Terminal 11: Mass supply actuator circuit ATerminal 12: Mass supply actuator circuit A (internally bridged to terminal 11)Terminal 5: Output actuator circuit B (-) (in relation to: Direction of movement "Open")+ 24V- GNDMotor circuit Bbrown+ 24V- GNDTerminal 6: Output actuator circuit B (+) (in relation to: Direction of movement"Open")MblueTerminal 7: Monitoring line actuator circuit BTerminal 8: Output “Open-display" for actuator circuit B (+24 V against mass)Idle if "Emergency operation".Terminal 13: 24 V supply actuator circuit BOutput “Open”Terminal 14: 24 V supply actuator circuit B (internally bridged to terminal 13)Terminal 15: Mass supply actuator circuit BTerminal 16: Mass supply actuator circuit B (internally bridged to terminal 15)BB5 6 7 813 14 15 16+ 24V+ 24V- GND - GND16 03/24999739

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!