By og Byg Dokumentation 058<br />

<strong>Måling</strong> <strong>på</strong> <strong>alternative</strong><br />

<strong>isoleringsmaterialer</strong><br />

Borup Seniorby - et demonstrationsprojekt


<strong>Måling</strong>er <strong>på</strong> <strong>alternative</strong><br />

<strong>isoleringsmaterialer</strong><br />

Borup Seniorby - et demonstrationsprojekt<br />

Torben Valdbjørn Rasmussen<br />

Asta Nicolajsen<br />

By og Byg Dokumentation 058<br />

<strong>Statens</strong> Byggeforskningsinstitut 2004


Titel <strong>Måling</strong>er <strong>på</strong> <strong>alternative</strong> <strong>isoleringsmaterialer</strong><br />

Undertitel Borup Seniorby - et demonstrationsprojekt<br />

Serietitel By og Byg Dokumentation 058<br />

Udgave 1. udgave<br />

Udgivelsesår 2004<br />

Forfatter Torben Valdbjørn Rasmussen, Asta Nicolajsen<br />

Sprog Dansk<br />

Sidetal 91<br />

Litteraturhenvisninger<br />

Side 42<br />

English<br />

summary Side 43-44<br />

Emneord Alternative <strong>isoleringsmaterialer</strong>, fugt, termografering, løsfyldsisolering, byggeteknik,<br />

demonstrationsbyggeri, cellulose, glasuld, høruld, stenuld, træfiber, perlit<br />

ISBN 87-563-1204-0<br />

ISSN 1600-8022<br />

Pris Kr. 220,00 inkl.25 pct. moms<br />

Tekstbehandling Solveig Susanne Johansen<br />

Fotos Torben Valdbjørn Rasmussen, Peter Mossing, Jan Carl Westphall<br />

Udgiver By og Byg<br />

<strong>Statens</strong> Byggeforskningsinstitut,<br />

P.O. Box 119, DK-2970 Hørsholm<br />

E-post by-og-byg@by-og-byg.dk<br />

www.by-og-byg.dk<br />

Eftertryk i uddrag tilladt, men kun med kildeangivelsen: By og Byg Dokumentation 058: <strong>Måling</strong>er <strong>på</strong> <strong>alternative</strong><br />

<strong>isoleringsmaterialer</strong>. Borup Seniorby - et demonstrationsprojekt. (2004)


Indhold<br />

Forord ..............................................................................................................5<br />

Sammenfatning og konklusion ........................................................................6<br />

Konklusion ..................................................................................................6<br />

Fugtophobning .......................................................................................6<br />

Isoleringsarbejdets udførelse.................................................................6<br />

Velegnede <strong>isoleringsmaterialer</strong>..............................................................7<br />

Indledning........................................................................................................8<br />

Baggrund ....................................................................................................8<br />

Formål.........................................................................................................8<br />

Metode........................................................................................................8<br />

Teori............................................................................................................9<br />

Forsøg vedrørende fugtophobning................................................................10<br />

Isoleringsmateriale....................................................................................10<br />

Byggeriet Borup Seniorby.........................................................................10<br />

Konstruktionernes opbygning ...................................................................13<br />

Påvirkninger..............................................................................................15<br />

Registrerede <strong>på</strong>virkninger....................................................................15<br />

Undersøgelsesmetode .........................................................................17<br />

Fugtmåler .............................................................................................17<br />

Dataopsamling .....................................................................................17<br />

Forsøgsperiode ....................................................................................18<br />

Resultater vedrørende fugtophobning ......................................................18<br />

Diskussion.................................................................................................22<br />

Klima<strong>på</strong>virkning....................................................................................22<br />

Usikkerhed ...........................................................................................22<br />

Kriterier.................................................................................................22<br />

Fugtophobning i <strong>isoleringsmaterialer</strong> ...................................................22<br />

Er isoleringsarbejdet udført korrekt? .............................................................23<br />

Termografering .........................................................................................23<br />

<strong>Måling</strong>er................................................................................................23<br />

Resultat af termografering ........................................................................23<br />

Bemærkninger til termografering ..............................................................25<br />

Kategori A: Kolde overgange mellem lejlighedsskel og loft .................25<br />

Kategori B: Kolde hjørner mellem lejlighedsskel og facade.................26<br />

Kategori C: Kolde fodpaneler langs facade .........................................27<br />

Kategori D: Kolde områder ved spær, lagt an <strong>på</strong> bagvæg af<br />

letklinkerbeton ......................................................................................28<br />

Kategori E: Kolde områder i den isolerede facade ..............................29<br />

Kategori F: Kolde områder i den isolerede facade langs loftet............30<br />

Kategori G: Kolde hjørner ved lejlighedsskel/gavl, loft og facade........33<br />

Diskussion.................................................................................................34<br />

Årsag til lokalt forekommende temperaturforskelle..............................34<br />

Beregning af hulrum.............................................................................35<br />

Varmestrømsberegning........................................................................35<br />

Beregning af hulrum i facade isoleret med Ekofiber ............................37<br />

Temperatur ved overgangen mellem facade og loft.................................38<br />

Beregning af hulrum langs loft i facaden isoleret med Ekofiber ...............39<br />

Beregnede hulrum ....................................................................................40<br />

Manglende isolering .............................................................................41<br />

Litteratur ........................................................................................................42<br />

Summary .......................................................................................................43<br />

Bilag A Temperatur og fugt i facade- og loftkonstruktioner...........................45<br />

3


4<br />

Bilag B Temperatur og relativ luftfugtighed i lejligheder............................... 82<br />

Bilag C Temperatur og relativ luftfugtighed udendørs og i teknikrum .......... 91


Forord<br />

Borup Seniorby er udefra set en helt almindelig bebyggelse, men Borup Seniorby<br />

er også et demonstrationsbyggeri, der har til formål at demonstrere<br />

og dokumentere anvendelsen af en lang række traditionelle og <strong>alternative</strong><br />

<strong>isoleringsmaterialer</strong>.<br />

Bebyggelsen har givet en god mulighed for, i en række næsten ens boliger,<br />

at dokumentere de forskellige <strong>isoleringsmaterialer</strong>nes egenskaber vedrørende<br />

isoleringsevne, fugtophobning, arbejdsmiljø og isoleringsarbejdets<br />

udførelse. Denne dokumentation er nødvendig for at et bredt udsnit af projekterende<br />

og udførende rutinemæssigt kan anvende <strong>alternative</strong> <strong>isoleringsmaterialer</strong>.<br />

Forud for denne rapport har By og Byg udfærdiget en rapport med titlen<br />

"Praktiske erfaringer med <strong>alternative</strong> <strong>isoleringsmaterialer</strong>" (Valdbjørn Rasmussen<br />

& Feilberg Hansen, 2004). I rapporten er bebyggelsen præsenteret,<br />

og såvel <strong>isoleringsmaterialer</strong> som indbygningsprocesser er beskrevet, herunder<br />

indbygning af måleudstyr til måling af temperaturer og fugt.<br />

I tilknytning til projektet er der endvidere gennemført en undersøgelse af<br />

støvbelastningen knyttet til arbejdet med de valgte produkter og den valgte<br />

arbejdsproces. Resultaterne fra dette arbejde er rapporteret i (Breum,<br />

Schneider, Flyvholm, Jørgensen, Valdbjørn Rasmussen & Skibstrup Eriksen,<br />

2003).<br />

En særlig tak rettes til bygherren, Dansk SeniorByg A/S, der sammen<br />

med By og Byg realiserede muligheden for at gennemføre projektet. Søren<br />

Skibstrup Eriksen forestod ledelsen af By og Bygs andel frem til byggeriets<br />

afslutning i 2002.<br />

Demonstrationsprojektet og de tilknyttede undersøgelser er udført med<br />

økonomisk støtte fra Energistyrelsens udviklingsprogram Miljø- og arbejdsmiljøvenlig<br />

<strong>isoleringsmaterialer</strong>.<br />

By og Byg, <strong>Statens</strong> Byggeforskningsinstitut<br />

Afdelingen for Byggeteknik og Design<br />

Juni 2004<br />

Jørgen Munch-Andersen<br />

Konstitueret forskningschef<br />

5


6<br />

Sammenfatning og konklusion<br />

Interessen for at anvende <strong>alternative</strong> <strong>isoleringsmaterialer</strong>, fx papir, hør og<br />

ekspanderet perlit, har været stigende gennem de seneste år. Dette har<br />

medført et øget behov for at få kendskab til <strong>isoleringsmaterialer</strong>nes egenskaber,<br />

herunder hvordan de fungerer sammenlignet med de traditionelle<br />

<strong>isoleringsmaterialer</strong> af mineraluld.<br />

I denne rapport besvares følgende spørgsmål vedrørende <strong>isoleringsmaterialer</strong><br />

i konstruktionerne i Borup Seniorby:<br />

– vil der i løbet af en vinter, ske en skadelig fugtophobning i de konkrete<br />

konstruktioner med de valgte <strong>isoleringsmaterialer</strong>?<br />

– er isoleringsarbejdet udført korrekt, dvs. udfylder isoleringsmaterialet de<br />

hulrum, der skal isoleres?<br />

– er det enkelte isoleringsmateriale specielt velegnet til alle typer konstruktioner,<br />

eller bør der stilles specielle krav til konstruktionernes udformning?<br />

I Borup Seniorby er byggeriets boliger, to og to, isoleret med det samme<br />

isoleringsmateriale. Der blev isoleret med ni forskellige <strong>isoleringsmaterialer</strong>,<br />

fem løsfyldsprodukter, to typer hør og to typer mineraluld, se tabel 1. Konstruktionerne<br />

har været <strong>på</strong>virket af det aktuelle ude- og indeklima.<br />

Fugtindholdet i isoleringen i facadeelementer og i loftkonstruktioner blev<br />

registreret med fugtmåledyvler anbragt i konstruktionernes varme og kolde<br />

side. I isoleringen i facaden umiddelbart bag den tunge bagvæg af letklinkerbeton<br />

og i isoleringen umiddelbart bag vindspærren af vindgips. Alle resultater<br />

af fugtmålingerne er angivet i vægt pct. fugt i træ (træ-fugt), for at<br />

kunne sammenlignes med faregrænsen for svampeangreb <strong>på</strong> 20 % træ-fugt.<br />

For at undersøge om isoleringsarbejdet er udført korrekt, er der fortaget<br />

en termografisk registrering af de indvendige overflader. Termograferingen<br />

blev udført en vinterdag med svag til frisk vind og en udetemperatur <strong>på</strong> -1<br />

°C.<br />

Konklusion<br />

Fugtophobning<br />

Fugtmålinger i de enkelte <strong>isoleringsmaterialer</strong> viser, at der ikke sker en skadelig<br />

fugtophobning i isoleringen i de her anvendte konstruktioner, uanset<br />

om de er isoleret med <strong>alternative</strong> <strong>isoleringsmaterialer</strong> eller med mineraluld,<br />

idet de målte fugtindhold alle er under 20 % træ-fugt.<br />

Der er ikke signifikant forskel mellem middelværdien af fugtophobningen i<br />

de <strong>alternative</strong> <strong>isoleringsmaterialer</strong> og middelværdien af fugtophobningen i<br />

mineraluld.<br />

Der er lidt større fugtophobning den første vinter end den anden vinter.<br />

Dette indikerer, at der har været indbygget en vis mængde byggefugt.<br />

Isoleringsarbejdets udførelse<br />

Den termografiske gennemgang af de indvendige overflader viser, at uanset<br />

hvilket isoleringsmateriale der er anvendt, er der konstateret afgrænsede<br />

områder med lavere temperaturer end omgivelserne.<br />

Selv om der er afvigelser mellem de registrerede temperaturforskelle, kan<br />

der, ud fra de her refererede målinger, ikke konstateres signifikante afvigelser<br />

mellem temperaturforskelle <strong>på</strong> overflader af konstruktioner, der er isoleret<br />

med <strong>alternative</strong> <strong>isoleringsmaterialer</strong> og temperaturforskelle <strong>på</strong> overflader<br />

af konstruktioner, der er isoleret med mineraluld. Der er dog registreret lidt


højere temperaturforskelle <strong>på</strong> overflader af konstruktioner, der er isoleret<br />

med Perlite end <strong>på</strong> de øvrige overflader.<br />

Årsagen til lokalt forekommende temperaturforskelle kan ikke med sikkerhed<br />

angives, uden at der er foretaget en destruktiv undersøgelse af konstruktionen.<br />

Nogle af de lokalt forekommende temperaturforskelle indikerer<br />

at isoleringsarbejdet lokalt ikke er udført korrekt, eller at der er sket sætninger<br />

i isoleringen. Andre af de lokalt forekommende temperaturforskelle indikerer<br />

at der er væsentlige kuldebroer, dels ved fodpaneler langs facaden,<br />

hvilket må tilskrives en dårlig kuldebroafbrydelse mellem fundament og dæk,<br />

dels ved overgangen mellem lejlighedsskel og loft, idet lejlighedsskel er ført<br />

ubrudt op i loftrum som brandsektionering.<br />

Velegnede <strong>isoleringsmaterialer</strong><br />

Et materiales egnethed som isoleringsmateriale i en given konstruktion bedømmes<br />

<strong>på</strong> grundlag af materialets praktiske varmeledningsevne, den praktiske<br />

håndtering <strong>på</strong> en byggeplads og om materialet er i stand til at opretholde<br />

sin funktion i bygningens levetid.<br />

Tidligere observationer af indbygningen af de enkelte <strong>isoleringsmaterialer</strong><br />

har vist, at med en fornuftig udformning af konstruktionerne kan de anvendte<br />

<strong>isoleringsmaterialer</strong> håndteres <strong>på</strong> byggepladsen uden væsentlige problemer<br />

(Valdbjørn Rasmussen & Feilberg Hansen, 2004). Observationer foretaget i<br />

bebyggelsen under indbygningen af isoleringsmaterialet har dog vist, at det<br />

er nødvendigt at specificere krav til konstruktionernes tæthed, når der skal<br />

isoleres med løsfyldsprodukter. Kravet til konstruktionernes tæthed gælder<br />

alle typer samlinger og gennemføringer. Entreprenører og rådgivere bør være<br />

opmærksomme <strong>på</strong>, at kravet til konstruktionernes tæthed afhænger af<br />

løsfyldsisoleringens partikelstørrelse, idet en isolering med mange små partikler<br />

kræver en meget tæt konstruktion.<br />

Generelt skal konstruktionen i klimaskærmen være lufttæt, for at være<br />

velegnet til enhver form for isolering. Både for at forhindre fugtophobning i<br />

den isolerede del af klimaskærmen, men også for at forhindre luftgennemstrømning<br />

i den isolerede del af klimaskærmen, som vil reducere isoleringsevnen<br />

af isoleringsmaterialet.<br />

7


8<br />

Indledning<br />

Interessen for at anvende <strong>alternative</strong> <strong>isoleringsmaterialer</strong> fx papir, hør og<br />

ekspanderet perlit har været stigende gennem de seneste år. Dette har<br />

medført et øget behov for at få kendskab til <strong>isoleringsmaterialer</strong>nes egenskaber,<br />

herunder hvordan de fungerer sammenlignet med de traditionelle<br />

<strong>isoleringsmaterialer</strong> af mineraluld.<br />

Baggrund<br />

Denne rapport er en del af afrapporteringen af et demonstrationsprojekt. I<br />

projektet blev det undersøgt, hvordan det er at montere de enkelte <strong>isoleringsmaterialer</strong>,<br />

og det hertil knyttede arbejdsmiljø blev målt. Desuden blev<br />

det undersøgt, hvordan de enkelte <strong>isoleringsmaterialer</strong> fungerer herunder<br />

om der sker en skadelig opfugtning i løbet af vinteren.<br />

De praktiske erfaringer der er høstet, ved at følge isoleringsarbejdet under<br />

opførelsen af demonstrationsbyggeriet Borup Seniorby, er rapporteret i<br />

By og Byg publikationen "Praktiske erfaringer med alternativ isolering"<br />

(Valdbjørn Rasmussen & Feilberg Hansen, 2004).<br />

De arbejdsmiljømæssige gener, som er knyttet til anvendelsen af <strong>isoleringsmaterialer</strong>,<br />

er primært hud- og luftvejsgener for isoleringsarbejderne,<br />

knyttet til forekomster af støv. <strong>Måling</strong>erne af støvforekomster samt en vurdering<br />

af behovet for beskyttelsesdragter og åndedrætsværn blev ikke foretaget<br />

<strong>på</strong> byggepladsen, men foretaget ved isolering af en sektion af byggeriet<br />

opført som en fuldskalamodel i en forsøgshal hos By og Byg. <strong>Måling</strong>erne er<br />

rapporteret af Arbejdsmiljøinstituttet i (Breum et al., 2002).<br />

Formål<br />

Formålet for den del af projektet der er afrapporteret her, er at belyse følgende<br />

spørgsmål:<br />

– vil der i løbet af en vinter, ske en skadelig fugtophobning i de her valgte<br />

konstruktioner med de valgte <strong>isoleringsmaterialer</strong>?<br />

– er isoleringsarbejdet udført korrekt, dvs. udfylder isoleringsmaterialet de<br />

hulrum, der skal isoleres?<br />

– er det enkelte isoleringsmateriale velegnet til alle typer konstruktioner, eller<br />

bør der stilles specielle krav til konstruktionernes udformning?<br />

Metode<br />

<strong>Måling</strong> af den fugtophobning, der i løbet af en vinter sker i konstruktioner<br />

isoleret med <strong>alternative</strong> <strong>isoleringsmaterialer</strong>, kan bedst ske ved at udsætte<br />

konstruktionerne for en fugtbelastning svarende til belastningen i almindelige<br />

boliger. Det blev derfor valgt at instrumentere facader og loftkonstruktioner i<br />

en række ens boliger, isoleret med forskellige <strong>alternative</strong> <strong>isoleringsmaterialer</strong>,<br />

og som reference måle i tilsvarende boliger isoleret med traditionelle og<br />

velkendte isoleringsprodukter af mineraluld.<br />

For at undersøge om isoleringsarbejdet er udført korrekt, dvs. om isoleringsmaterialet<br />

udfylder det hulrum, der skal isoleres, foretages termovision


af de indvendige overflader under vinterforhold. Ved termovision registreres<br />

de indvendige overfladers temperatur ved en fotografisk lignende proces.<br />

Teori<br />

I rapporten (Stang, 2002) er der en kort beskrivelse af den teoretiske baggrund<br />

for kondensdannelse i facadekonstruktioner. En mere grundlæggende<br />

gennemgang af emnet kan findes i SBI-anvisning 178 (Andersen, Christensen<br />

& Nielsen, 1993) eller i (Nevander og Elmarsson, 1994). Den teoretiske<br />

baggrund for den her rapporterede undersøgelse kan kort resumeres som<br />

følger:<br />

Den relative luftfugtighed bestemmes af luftens fugtindhold i forhold til<br />

den maksimale mængde fugt der kan indeholdes ved den givne temperatur.<br />

Ved afkøling af varm fugtig luft vil den relative luftfugtighed<br />

stige indtil en relativ luftfugtighed <strong>på</strong> 100 % (mætningsdamptrykket)<br />

nås. Hvis luften afkøles yderligere, vil der dannes kondens, som typisk<br />

vil sætte sig <strong>på</strong> kolde overflader. Luftens fugtindhold som funktion af<br />

temperaturen kan optegnes som et vanddampdiagram. Af et vanddampdiagram<br />

kan bl.a. aflæses, at luft ved en typisk indendørs<br />

temperatur <strong>på</strong> 22 °C kan indeholde omkring 4 gange mere vand i g/m 3<br />

end luft ved 0 °C.<br />

Fugtindholdet indendørs regnet i g/m 3 følger generelt fugtindholdet<br />

i udeluften. Der er dog et væsentligt bidrag fra husets beboere, madlavning,<br />

badning og tøjtørring mm. Begrænset udluftning vil derfor bevirke,<br />

at fugtindholdet indendørs er højere end fugtindholdet udendørs.<br />

Dette gælder selv om forskellen i temperatur ude og inde bevirker,<br />

at den relative luftfugtighed er væsentlig lavere indendørs. Fugttransporten<br />

gennem materialer styres af forskellen i partialdamptryk<br />

(Lund-Hansen, 1967). Partialdamptrykket er en funktion af vanddamp<br />

koncentrationen og temperaturen. På en typisk vinterdag med en<br />

temperatur <strong>på</strong> 0 °C og en relativ luftfugtighed <strong>på</strong> 90 % RF er partialdamptrykket<br />

udendørs 550 Pa, mens det tilsvarende typiske indendørs<br />

partialdamptryk ved en temperatur <strong>på</strong> 20 °C og en relativ luftfugtighed<br />

<strong>på</strong> 40 % RF er 930 Pa. Da partialdamptrykket er højere inde<br />

end ude, vil der være en transport af fugt indefra og ud.<br />

På grund af denne fugttransport gennem ydervægskonstruktioner<br />

er det vigtigt at opbygge vægge <strong>på</strong> en måde, så fugttransporten ikke<br />

standses inde i væggen. Dette sikres ved at have en høj dampdiffu<br />

sionsmodstand <strong>på</strong> den varme side af konstruktionen og omvendt have<br />

en lav dampdiffusionsmodstand længere ude i konstruktionen. En<br />

tommelfingerregel siger, at damdiffusionsmodstanden <strong>på</strong> den varme<br />

side af isoleringen skal være 10 gange større end dampdiffusionsmodstanden<br />

<strong>på</strong> den kolde side af isoleringen. På denne måde sikres<br />

at der ikke ophobes fugt i konstruktionen.<br />

Skadelig fugtophobning i konstruktioner kan skyldes indtrængning af vand fx<br />

gennem mangelfulde inddækninger eller kondens i konstruktionen. De fleste<br />

konstruktioner udføres med en dampspærre for at undgå kondens, men facadekonstruktioner,<br />

som de her undersøgte med en bagvæg af letklinkerbeton,<br />

udføres normalt uden dampspærre.<br />

By og Byg har i en undersøgelse (Stang, 2002) vist, at facadekonstruktioner<br />

med bagvæg af letklinkerbeton er yderst følsomme over for fugt.<br />

De tidligere undersøgte facadekonstruktioner har alle været udført med<br />

mineraluld. Det er derfor vigtig, at undersøge om anvendelse af andre <strong>isoleringsmaterialer</strong><br />

har indflydelse <strong>på</strong> den fugtophobning, der sker i facadekonstruktionen.<br />

9


10<br />

Forsøg vedrørende fugtophobning<br />

Isoleringsmateriale<br />

Til isolering af byggeriet blev der valgt ni forskellige isoleringsprodukter, som<br />

alle var tilgængelige <strong>på</strong> det danske marked ved byggeriets start. De enkelte<br />

produkter er enten anvendt som løsfyld eller som formstykker. Tabel 1 indeholder<br />

en oversigt over de anvendte produkter opdelt efter materiale og producenter,<br />

og om de er anvendt som løsfyld eller som formstykker.<br />

Tabel 1. Isoleringsprodukter anvendt som varmeisoleringsmateriale i Borup Seniorby.<br />

Materiale Produktnavn Producent Type<br />

Cellulose (genbrugspapir) Ekofiber, vind Ekofiber AB Løsfyld<br />

Cellulose (genbrugspapir) Isodan Isodan Løsfyld<br />

Cellulose (genbrugspapir) Papiruld Miljøisolering ApS Løsfyld<br />

Træfiber Thermocell Thermocell Danmark A/S Løsfyld<br />

Høruld Høruld i formstykker Dansk Naturisolering A/S Formstykker<br />

Høruld Heraflax Heraklith Formstykker<br />

Perlit Perlit, 0515SC Nordisk Perlite ApS Løsfyld<br />

Stenuld Rockwool, A-batts Rockwool A/S Formstykker<br />

Glasuld Isover Saint Gobain Isover A/S Formstykker<br />

Byggeriet Borup Seniorby<br />

Byggeriet består af 24 selvstændige boliger fordelt <strong>på</strong> tre selvstændige længehuse<br />

(blokke) i 1-2 etager med hver otte lejligheder. Figur 1 og figur 2 viser<br />

udsnit af bebyggelsen. Bebyggelsen er nærmere beskrevet i (Valdbjørn<br />

Rasmussen & Feilberg Hansen, 2004), her er byggeriets parter ligeledes<br />

nævnt. Byggeriets boliger er to og to isoleret med samme isoleringsmateriale.<br />

Figur 3 viser hvor i byggeriet de ni <strong>isoleringsmaterialer</strong> er placeret.


Figur 1. Et af de tre længehuse i 1-2 etager som udgør bebyggelsen Borup Seniorby. Facaden vender<br />

mod vest og gavlen mod syd.<br />

Figur 2. Et af de tre længehuse i 1-2 etager som udgør bebyggelsen Borup Seniorby. Facaden vender<br />

mod vest. Bygningen er set fra nord.<br />

11


12<br />

N<br />

Blok A<br />

Blok B<br />

Blok C<br />

Thermocell<br />

Isodan<br />

Ekofiber<br />

Heraflex Rockwool<br />

Underetage<br />

Hør i formstykker Isover<br />

Underetage<br />

Papiruld Perlite<br />

Underetage<br />

Figur 3. Placeringen af de ni isoleringsprodukter i byggeriets tre blokke. Byggeriets underetager og<br />

gavle er isoleret med Isover.


Konstruktionernes opbygning<br />

Figur 4 viser et tværsnit i 2 etager. Opbygningen af de konstruktioner der er<br />

væsentlige for forståelse af resultaterne, er angivet nedenfor. Opbygningen<br />

af de øvrige konstruktioner er angivet i (Valdbjørn Rasmussen & Feilberg<br />

Hansen, 2004).<br />

Figur 4. Tværsnit i 2 etagers længehus.<br />

13


14<br />

Facaderne er opbygget af:<br />

– 100 mm bærende bagvæg i helvægselementer af letklinkerbeton<br />

– træstolper per 600 mm med 200 mm isolering<br />

– 9 mm udvendig vindgips<br />

– ventileret luftspalte<br />

– udvendig beklædning af træ <strong>på</strong> klink eller fibercementplader.<br />

Nogle af facaderne er udført med toprem andre uden toprem, så der er forbindelse<br />

imellem loftisoleringen og facadeisoleringen.<br />

Lejlighedsskellene er opbygget af:<br />

– 150 mm letklinkerbetonelementer.<br />

Letklinkerbetonelementerne er ført ubrudt op igennem tagrummet til undersiden<br />

af tagbeklædningen.<br />

Loftkonstruktionen er opbygget af:<br />

– 2 lag 13 mm gipsplade,<br />

– dampspærre,<br />

– forskalling,<br />

– gitterspær per 900 mm med isolering.<br />

Tykkelsen af loftisoleringen er beregnet af den rådgivende ingeniør ud fra<br />

varmetabsberegninger. Isoleringstykkelsen er, sammen med den til beregningen<br />

anvendte varmeledningsevne (lambda), angivet i tabel 2.<br />

Beregningerne af varmetabet er udført efter DS 418 (Dansk Ingeniørforening,<br />

1986 og Dansk Standard, 2000). Beregningerne af varmetabet skal<br />

blandt andet sikre, at varmetabet for den enkelte bolig ligger inden for varmetabsrammen,<br />

angivet i BR 95 (Boligministeriet, 1995). Alle gavle (undtagen<br />

i bolig med termocell) og facader i underste etage i de to-etagers boliger<br />

er isoleret med Isover.<br />

Kravet om max. U-værdi for tagkonstruktioner <strong>på</strong> 0,25 W/m 2 K medfører<br />

minimum 150 mm mineraluld i tagkonstruktioner.<br />

De udvendige overflader for de enkelte boliger har forskellige arealer, og<br />

de anvendte <strong>isoleringsmaterialer</strong> har forskellige lambda. Det er derfor nødvendigt,<br />

<strong>på</strong> lofterne at anvende isolering af forskellig tykkelse for at alle boliger<br />

kan få det samme samlede varmetab. Tykkelserne af loftisolering er beregnet<br />

ved, at der for hver isoleringstype er beregnet et samlet varmetab for<br />

boligerne isoleret med den aktuelle isoleringstype og med Isover. Derefter er<br />

der beregnet hvor meget mere af den aktuelle isolering, der skal lægges <strong>på</strong><br />

loftet for at få det samme varmetab som med Isover.<br />

For løsuldsprodukter er der tillagt den i DS 418 krævede overtykkelse (til<br />

sætning) <strong>på</strong> henholdsvis 25 % for cellulosefibre og 1 % for ekspanderet perlit.


Tabel 2. Varmeledningsevne for væg- og loftisolering samt tykkelse af loftisolering.<br />

Lambda, væg<br />

W/mK<br />

Lambda, loft<br />

W/mK<br />

Ekofiber 0,050 0,055 415<br />

Isodan 0,050 0,055 375<br />

Papiruld 0,050 0,055 375<br />

Thermocell 0,055 0,055 280<br />

Høruld i formstykker 0,055 0,055 200<br />

Heraflax 0,042 0,042 200<br />

Perlite 0,045 0,045 200<br />

Rockwool 0,039 0,039 150<br />

Isover 0,039 0,039 150<br />

Påvirkninger<br />

Isoleringstykkelse <strong>på</strong> loft<br />

mm<br />

Den fugt<strong>på</strong>virkning facade- og loftkonstruktioner med de valgte <strong>isoleringsmaterialer</strong><br />

bliver udsat for, afhænger af forskellen i damptryk <strong>på</strong> de to sider<br />

af konstruktionerne, dvs. indendørs og udendørs. Damptrykket er en funktion<br />

af temperatur og relativ luftfugtighed. Det er specielt vigtigt at måle temperatur<br />

og relativ luftfugtighed indendørs, fordi temperatur og relativ luftfugtighed<br />

højere end ”normalt”, kan bevirke høj fugtophobning i isoleringen,<br />

hvilket kan tolkes som et problem for organiske <strong>isoleringsmaterialer</strong>.<br />

Temperatur og relativ luftfugtighed blev målt ved hjælp af TinyTags af typen<br />

TGU-1500. TGU-1500, som er en datalogger med dimensionerne 72 x<br />

60 x 33 mm 3 med en vægt <strong>på</strong> 50 g. Den kan måle både temperatur og relativ<br />

luftfugtighed. Temperaturer mellem 0 og 50 °C kan måles med en nøjagtighed<br />

<strong>på</strong> ± 0,2 °C. Den relative luftfugtighed mellem 0 og 95 % kan måles med<br />

en nøjagtighed <strong>på</strong> ± 3 % ved 23 °C. Hver enkelt TinyTags blev efter måleperiodens<br />

ophør kontrolleret ved 23 °C og henholdsvis 50, 65 og 80 % RF, for<br />

om nødvendigt at kunne korrigere målingerne opsamlet i bebyggelsen. I<br />

hver lejlighed blev temperatur og relativ luftfugtighed målt i stuen, i badeværelse<br />

og i et vestvendt værelse, der blev anvendt som kontor eller soveværelse.<br />

Temperatur og relativ luftfugtighed blev også målt seks skyggefulde<br />

steder udendørs i de seks lejligheder beliggende i underetagen og i de tre<br />

uopvarmede teknikrum.<br />

Registrerede <strong>på</strong>virkninger<br />

Temperatur og relativ luftfugtighed blev målt hver anden time i perioden juni<br />

2002 til maj 2003.<br />

Temperatur og relativ luftfugtighed i de enkelte boliger, herunder også i<br />

boliger beliggende i underetagen i den del af byggeriet der er i to etager, er<br />

vist i bilag B, figur 151 til figur 174. Temperatur og relativ luftfugtighed udendørs<br />

og i de tre uopvarmede teknikrum er vist i bilag C, figur 175 og figur<br />

176.<br />

Et eksempel <strong>på</strong> opsamlede data, temperatur og relativ luftfugtighed i en<br />

lejlighed isoleret med Isover er vist i figur 5. Her er vist middelværdier målt<br />

over fem døgn (60 målinger) for at udjævne døgnvariationen ved brug af boligens<br />

funktioner. I bilag B, figur 166 er alle måleværdier for lejligheden vist.<br />

Temperatur og relativ luftfugtighed målt i samtlige lejligheder er vist i bilag B,<br />

figur 151 til figur 174.<br />

15


16<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

Lejlighed B 1.6, Isover<br />

september 01 januar 02 juni 02 oktober 02<br />

Tid [måned:år]<br />

marts 03<br />

Stue, RF<br />

Stue, T<br />

Kontor, RF<br />

Kontor, T<br />

Bad, RF<br />

Bad, T<br />

Figur 5. Middelværdier af temperatur og relativ luftfugtighed målt over 5 døgn i en bolig isoleret med<br />

formstykker af mineraluld i form af glasuld fra Isover. <strong>Måling</strong>erne er foretaget i stuen, i kontoret og i<br />

badeværelset.<br />

<strong>Måling</strong> af temperatur og relativ luftfugtighed i den enkelte bolig havde til formål,<br />

at dokumentere det indeklima konstruktionerne blev <strong>på</strong>virket af. Resultaterne<br />

peger <strong>på</strong> en brug af de enkelte boliger, som er i overensstemmelse<br />

med almindelig brug, idet de observerede temperaturer og relative luftfugtigheder<br />

er inden for det, der i Bygningers fugtisolering (Andersen, Christensen<br />

& Nielsen, 1999) angives som svarende til en almindelig brug af boligen.<br />

Eksempler <strong>på</strong> temperaturer og relative luftfugtigheder målt udendørs er<br />

vist i figur 6. Her er vist middelværdier målt over fem døgn (60 målinger) for<br />

at udjævne døgnvariationen. I bilag C, figur 175 er angivet temperaturer målt<br />

uden for blokkenes teknikrum og i figur 176 temperatur og relativ luftfugtighed<br />

i teknikrummene.<br />

De TinyTags der målte temperaturer udendørs skulle også måle den relative<br />

luftfugtighed udendørs, men bortset fra de to viste måleserier, var måleværdierne<br />

ikke <strong>på</strong>lidelige. En nærmere undersøgelse viser, at TinyTags anvendelsesinterval<br />

op til 95 % relativ luftfugtighed øjensynlig skal tages meget<br />

bogstaveligt, da målinger tæt <strong>på</strong> grænseværdien ofte resulterer i et 100 %<br />

udslag. Den efterfølgende kalibrering ved 80 % relativ luftfugtighed og ca. 23<br />

°C af de TinyTags der var anvendt udendørs, viste en fejl <strong>på</strong> målingerne, så<br />

måleværdierne blev ca. 5% for høje.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Udendørs ved udhus<br />

-10<br />

september 01 januar 02 juni 02 oktober 02 marts 03<br />

Tid [måned:år]<br />

Ved blok A, RF Ved blok C, RF Ved blok A, T Ved blok C, T<br />

Figur 6. Middelværdier af temperatur og relativ luftfugtighed målt over fem døgn udendørs ved et udhus<br />

i blok A og blok C.<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

RF [%]<br />

RF [%]


Undersøgelsesmetode<br />

For at undersøge om der sker en skadelig fugtophobning i konstruktionerne,<br />

måles over to vintre fugtindholdet i isoleringen, dels for at sikre at en evt. høj<br />

fugtophobning den første vinter ikke skyldes byggefugt, og dels for at få målt<br />

om der sker en tilstrækkelig udtørring i løbet af forår og sommer.<br />

Fugtindholdet måles i facade og loftisoleringen i følgende punkter:<br />

– I facader mod vest måles der for hver type isoleringsmateriale i facader<br />

ud for stue og værelse.<br />

– I facader mod øst måles der for hver type isoleringsmateriale i facader ud<br />

for bad og ud for værelse eller køkken, således at der for hvert isoleringsmateriale<br />

bliver målt i en facade ud for et værelse og køkken.<br />

– I loftkonstruktionen måles der for hver type isoleringsmateriale over bad<br />

og køkken.<br />

I hvert punkt bliver fugtindholdet målt i den varme og i den kolde side af isoleringen.<br />

I facaderne måles der ca. 400 mm over bundremmen, se figur 4 og<br />

ca. 40 mm under facadeisoleringens øverste kant, begge steder midt mellem<br />

to træstolper. For loftisoleringen af løsuld er målerne, til måling i den kolde<br />

side af isoleringen, anbragt i en højde, der er ca. 40 mm lavere end den beregnede<br />

isoleringstykkelse (tabel 2). Dette betyder, at der for løsuldsprodukter<br />

kan være op til 80 mm isolering over målepunktet <strong>på</strong> grund af den i<br />

DS 418 krævede overtykkelse til sætning.<br />

Fugtmåler<br />

Fugtmålerne består af en fugtmåledyvel af bøgetræ og en termistor til måling<br />

af temperaturen (til korrektion). Fugten bestemmes ved måling af modstanden<br />

mellem to elektroder, der er presset ned i trædyvelen. Modstanden omregnes<br />

til fugtindhold ved hjælp af kalibreringskurver (Brandt, Hjorslev Hansen,<br />

Hommel Hansen & Mossing, 1998). Fugtindholdet angives, selv om det<br />

er målt i et isoleringsmateriale, som vægtpct. fugt i træ (træ-fugt), dvs. svarende<br />

til fugtindholdet i trædyvelen.<br />

Kalibrering af fugtmåledyvlerne er tidskrævende og dermed forbundet<br />

med store omkostninger. Derfor kalibreres de enkelte fugtdyvler ikke, men<br />

inden forsøgene kontrolleres fugtdyvlerne samlet ved 80 % relativ luftfugtighed<br />

og 23 ° C. Kravet for godkendelse af den enkelte fugtdyvel er, at målingen<br />

ikke afviger mere end 5 % fra middelværdien af alle målingerne.<br />

Fugtmåledyvler og termistorer er parvist monteret <strong>på</strong> pvc-vinkler, der er<br />

skruet fast i henholdsvis bagvæggen eller forskallingen i loftkonstruktionen.<br />

På pvc-vinklerne er der monteret en såkaldt ”node” (engelsk: knudepunkt),<br />

hvortil fugtmåledyvler og termistorer er forbundet. I hver blok er alle ”nodes”<br />

serieforbundet til en PC, som bruges til at opsamle data.<br />

Dataopsamling<br />

Dataopsamlingen foregår ved hjælp af et PC styret program med automatisk<br />

gem af data og automatisk genopstart ved strømafbrydelse. I forsøgsperioden<br />

blev modstanden i dyvler og temperaturer målt og registreret 2 gange<br />

dagligt (kl. 12 og kl. 00). I måleperioden er der enkelte udfald af data, fordi<br />

dataloggeren til måleudstyret brød sammen. Nogle af dataene for den ene<br />

lejlighed isoleret med Perlite mangler, fordi ledningen til de serieforbundne<br />

målepunkter er afbrudt. Bruddet <strong>på</strong> ledningen kunne ikke lokaliseres, hvorfor<br />

forbindelsen ikke umiddelbart kunne genoprettes og dataene anses derfor<br />

for at være tabt.<br />

Enkelte termistorer til måling af temperaturen i et målepunkt er i forsøgsperioden<br />

holdt op med at fungere. Temperaturmålinger fra tilsvarende målepunkter<br />

i samme isoleringsmateriale er derfor benyttet ved beregningen af<br />

fugtindholdet.<br />

17


18<br />

Forsøgsperiode<br />

Byggeriet, instrumentering og indbygning af forsøgsudstyr blev udført i perioden<br />

fra december 2000 til september/oktober 2001.<br />

Forsøgene blev gennemført i perioden september (blok B og C)/oktober<br />

(blok A) 2001 til april 2003.<br />

Resultater vedrørende fugtophobning<br />

Temperaturforløb og fugtindhold i samtlige målepunkter i isoleringsmaterialet<br />

i hver enkelt bolig er optegnet i de grafer, der er vedlagt som figur 45 til figur<br />

150 i bilag A. For den enkelte bolig omfattet af undersøgelsen er temperaturer<br />

i loftisoleringen og i facaderne henholdsvis mod vest og øst, og fugtindhold<br />

i loftisoleringen og i facaderne henholdsvis mod vest og øst vist. Målepunkternes<br />

placering er beskrevet i afsnittet "Undersøgelsesmetode".<br />

Eksempler <strong>på</strong> målte temperaturer fra en lejligheden isoleret med formstykker<br />

af mineraluld i form af glasuld fra Isover er vist i figur 7 til figur 9. De<br />

målte temperaturer er vist som middelværdier af temperaturer målt over en<br />

periode <strong>på</strong> fem døgn (10 målinger). Temperaturen er målt i isoleringen <strong>på</strong><br />

henholdsvis den side som vender mod boligen (den varme side) og den side<br />

der vender mod det fri (den kolde side). Figur 7 viser temperaturer målt i<br />

loftisoleringen. Figur 8 viser temperaturer målt i vestvendt væg og figur 9 viser<br />

temperaturer målt i facadeisoleringen i en østvendt væg.<br />

Temperatur [ o C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.6, Isover, Loft<br />

-10<br />

september 01 januar 02 juni 02 oktober 02 marts 03<br />

Tid [måned:år]<br />

Loft ov er bad mod det fri Loft ov er bad mod boligen<br />

Loft ov er køkken mod det fri Loft ov er køkken mod boligen<br />

Figur 7. Temperaturer i loftisoleringen over en bolig, der er isoleret med formstykker af mineraluld i form<br />

af glasuld fra Isover. Temperaturerne er målt i isoleringen i henholdsvis den side, som vender mod boligen<br />

og i den kolde side, der vender mod loftrummet, og er angivet som middelværdi over fem døgn.


Temperatur [ o C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.6, Isover, Facade mod V<br />

-10<br />

september 01 januar 02 juni 02 oktober 02 marts 03<br />

Værelse, nedre mod det fri<br />

Tid [måned:år]<br />

Værelse, nedre mod boligen Værelse, øv re mod det fri<br />

Værelse, øv re mod boligen Stue, nedre mod det fri Stue, nedre mod boligen<br />

Stue, øv re mod det fri Stue, øv re mod boligen<br />

Figur 8. Temperaturer i isoleringen i facaden mod vest i en bolig, der er isoleret med formstykker af mineraluld<br />

i form af glasuld fra Isover. Temperaturerne er målt i isoleringen i henholdsvis den side, som<br />

vender mod boligen og i den kolde side og er angivet som middelværdi over fem døgn.<br />

Temperatur [ o C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.6, Isover, Facade mod Ø<br />

-10<br />

september 01 januar 02 juni 02 oktober 02 marts 03<br />

Bad, nedre mod det fri<br />

Tid [måned:år]<br />

Bad, nedre mod boligen Bad, øv re mod det fri<br />

Bad, øv re mod boligen Køkken, nedre mod det fri Køkken, nedre mod boligen<br />

Køkken, øv re mod det fri Køkken, øv re mod boligen<br />

Figur 9. Temperaturer i isoleringen i facaden mod øst i en bolig, der er isoleret med formstykker af mineraluld<br />

i form af glasuld fra Isover. Temperaturerne er målt i isoleringen i henholdsvis den side, som vender<br />

mod boligen og i den kolde side og er angivet som middelværdi over fem døgn.<br />

Eksempeler <strong>på</strong> fugtmålinger er vist i figur 10 til figur 12 for lejligheder isoleret<br />

med formstykker af mineraluld i form af glasuld fra Isover. Fugtindholdet er<br />

vist som middelværdi af træ-fugt målt over en periode <strong>på</strong> fem døgn (10 målinger).<br />

Fugtindholdet er målt i isoleringen <strong>på</strong> henholdsvis den side som vender<br />

mod boligen (den varme side) og den side der vender mod det fri (den<br />

kolde side). Fugtindholdet i isoleringsmaterialet er målt med trædyvel. Dyvelernes<br />

fugtindhold er i ligevægt med, og derfor et udtryk for, den relative<br />

luftfugtighed, som der er i isoleringen rundt om måledyvlen. Figur 10 viser<br />

fugtindhold i loftisoleringen. Figur 11 viser fugtindhold i isolering i facaden,<br />

som vender mod vest, og figur 12 viser fugtindhold i isolering i facaden, som<br />

vender mod øst.<br />

19


20<br />

Fugtindhold [vægt-%]<br />

20,0<br />

19,0<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.6, Isover, Loft<br />

10,0<br />

september 01 januar 02 juni 02 oktober 02 marts 03<br />

Tid [måned:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 10. Fugtindhold i loftisoleringen over en bolig, der er isoleret med formstykker af mineraluld i form<br />

af glasuld fra Isover. Fugtindholdet er målt i isoleringen i henholdsvis den side, som vender mod boligen<br />

og i den kolde side, der vender mod loftrummet. Fugtindholdet er angivet som vægtpct. i træ og som<br />

middelværdi over fem døgn.<br />

Fugtindhold [vægt-%]<br />

20,0<br />

19,0<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.6, Isover, Facade mod V<br />

10,0<br />

september 01 januar 02 juni 02 oktober 02 marts 03<br />

Tid [måned:år]<br />

Værelse, nedre mod det fri Værelse, nedre mod boligen Værelse, øvre mod det fri<br />

Værelse, øvre mod boligen St ue, nedre mod det f ri Stue, nedre mod boligen<br />

St ue, øvre mod det fri St ue, øvre mod boligen<br />

Figur 11. Fugtindhold i isoleringen i facade mod vest i en bolig, der er isoleret med formstykker af mineraluld<br />

i form af glasuld fra Isover. Fugtindholdet er målt i isoleringen i henholdsvis den side, som vender<br />

mod boligen og i den kolde side. Fugtindholdet er angivet som vægtpct. i træ og som middelværdi over<br />

fem døgn.<br />

Fugtindhold [vægt-%]<br />

20,0<br />

19,0<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.6, Isover, Facade mod Ø<br />

10,0<br />

september 01 januar 02 juni 02 oktober 02 marts 03<br />

Tid [måned:år]<br />

Bad, nedre mod det fri Bad, nedre mod boligen Bad, øvre mod det fri<br />

Bad, øvre mod boligen Køkken, nedre mod det fri Køkken, nedre mod boligen<br />

Køkken, øvre mod det fri Køkken, øvre mod boligen<br />

Figur 12. Fugtindhold i isoleringen i facade mod øst i en bolig, der er isoleret med formstykker af mineraluld<br />

i form af glasuld fra Isover. Fugtindholdet er målt i isoleringen i henholdsvis den side, som vender<br />

mod boligen og i den kolde side. Fugtindholdet er angivet som vægtpct. i træ og som middelværdi over<br />

fem døgn.


I tabel 3 til 5 er angivet det højeste fugtindhold om vinteren målt i den kolde<br />

side i henholdsvis loft- og facadeisoleringen. Værdierne er aflæst af graferne<br />

i bilag A, som den højeste værdi for hver af de to vintre, der er dog set bort<br />

fra deciderede spidsværdier der kan være fejlbehæftet og som under alle<br />

omstændigheder er så kortvarige at de er uden praktisk betydning.<br />

Middelværdien af de aflæste fugtindhold i <strong>alternative</strong> <strong>isoleringsmaterialer</strong> i<br />

facader er 13,3 træ-fugt og i mineraluld 13,6 træ-fugt.<br />

Tabel 3. Højeste fugtindhold i vægtpct. træ-fugt om vinteren i loftisoleringen i den kolde side, målt over<br />

bad og køkken.<br />

Lejlighed 1 Lejlighed 2<br />

1. Vinter 2. Vinter 1. Vinter 2. Vinter<br />

Bad Køkken Bad Køkken Bad Køkken Bad Køkken Middelværdi<br />

Ekofiber 12,5 12,5 12,5 12,5 12 12,5 12 12,5 12,4<br />

Isodan 13 14,5 12 13,5 13,5 12,5 12,5 12,5 13<br />

Papiruld 15 13 15 13 12,5 12,5 12,5 12,5 13,3<br />

Thermocell 14,5 14 12 12 14,5 14,5 12 12 13,2<br />

Høruld i f. st. 12,5 12,5 12,5 12,5 12 12 12 12 12,3<br />

Heraflex 13,5 12 12,5 12,5 14 12,5 12,5 12,5 12,8<br />

Perlite 12,5 12,5 12,5 12,5 13,5 12,5 12,7<br />

Rockwool 14,5 13 12,5 12 14 15 12 12,5 13,2<br />

Isover 14 12 12,5 12 12,5 12 12,5 12 12,4<br />

Tabel 4. Højeste fugtindhold i vægtpct. træ-fugt om vinteren i isoleringen ved fodremmen i facaden mod<br />

vest i den kolde side, målt ud for stue og værelse.<br />

Lejlighed 1 Lejlighed 2<br />

1. Vinter 2. Vinter 1. Vinter 2. Vinter<br />

Stue Værelse Stue Værelse Stue Værelse Stue Værelse Middelværdi<br />

Ekofiber 13 13 12 12 13,5 13,5 12 12 12,6<br />

Isodan 12,5 12,5 12 12 12,5 12,5 12 12 12,3<br />

Papiruld 12,5 12,5 12,5 12,5 13 13 12,5 12,5 12,6<br />

Thermocell 14,5 14,5 12,5 12,5 14,5 14,5 12 13 13,5<br />

Høruld i f. st. 15,5 15,5 14 14 13 15 12,5 15 14,3<br />

Heraflex 13 13 12,5 12,5 12 12 12 12 12,4<br />

Perlite 13,5 13,5 12,5 12,5 13<br />

Rockwool 16 13 13 12 14,5 14,5 13 13,5 13,7<br />

Isover 13,5 13,5 12,5 12,5 15 18 13,5 16 14,3<br />

Tabel 5. Højeste fugtindhold vægtpct. træ-fugt om vinteren i isoleringen ved fodremmen i facaden mod<br />

øst i den kolde side, målt ud for bad og værelse eller køkken.<br />

Lejlighed 1 Lejlighed 2<br />

1. Vinter 2. Vinter 1. Vinter 2. Vinter<br />

Bad Værelse Bad Værelse Bad Køkken Bad Køkken Middelværdi<br />

Ekofiber 13,5 14,5 12,5 12,5 13,5 14 12,5 12,5 13,2<br />

Isodan 15 15 12,5 12,5 15 15 12,5 12,5 13,8<br />

Papiruld 15 14,5 12,5 12,5 14,5 15 12,5 12,5 13,5<br />

Thermocell 16,5 16,5 15,5 15,5 16 15 15 14 15,5<br />

Høruld i f. st. 14,5 13 14 13 14 14 13 13 13,6<br />

Heraflex 12,5 12,5 12,5 12,5 13,5 12 12 12 12,4<br />

Perlite 15 17 12,5 13,5 16 12 14,3<br />

Rockwool 15 15,5 12 14 15,5 15 12,5 13 14,1<br />

Isover 12 14 12 12 13 13 12 12 12,5<br />

21


22<br />

Diskussion<br />

I diskussionen af forsøgsresultaterne indgår en vurdering af forsøgs<strong>på</strong>virkninger,<br />

usikkerhed <strong>på</strong> målingerne, og kriterier for acceptabelt fugtindhold.<br />

Klima<strong>på</strong>virkning<br />

Klima<strong>på</strong>virkningerne <strong>på</strong> konstruktionerne er temperatur og relativ luftfugtighed<br />

i den enkelte bolig og udendørs. <strong>Måling</strong>erne peger <strong>på</strong> en brug af boligerne,<br />

som er i overensstemmelse med almindelig brug. Ved vurdering af<br />

resultaterne skal der derfor tages højde for, at andre boliger kan have en<br />

højere fugt<strong>på</strong>virkning indefra, og at dette kan medføre en højere fugtophobning<br />

i konstruktionerne.<br />

Usikkerhed<br />

Års målinger af fugtindhold i konstruktioner, målt med fugtmåledyvler, hos<br />

By og Byg, har vist, at målingerne har en måleusikkerhed <strong>på</strong> 1-2 % træ-fugt.<br />

Kriterier<br />

Kriteriet for vurdering af, om der i konstruktionerne forekommer et uacceptabelt<br />

højt fugtindhold, er 20 % træ-fugt ved en temperatur <strong>på</strong> 5 °C. Dette er<br />

det normalt anvendte kriterium for vurdering af risiko for vækst af råd og<br />

trænedbrydende svampe. Det har dog været diskuteret, om kriterierne skulle<br />

ændres til et fugtindhold <strong>på</strong> 15 % træ-fugt <strong>på</strong> grund af risikoen for skimmelvækst,<br />

(Nevander og Elmarsson, 1994).<br />

Nyere forskning peger <strong>på</strong>, at der for træbaserede produkter ikke er risiko<br />

for skimmelvækst ved 20 °C når fugtniveau er under 16 % træ-fugt; at der er<br />

en svag risiko ved 16-18 % træ-fugt; middel risiko ved 18-20 % træ-fugt og<br />

stor risiko når fugtniveauet er over 20 % træ-fugt hvis opfugtningen er langvarig<br />

(By og Byg anvisning 204). I dette arbejde er det valg at fastholde<br />

grænsen for det maksimale fugtindhold <strong>på</strong> 20 % træ-fugt ved 5 °C.<br />

Fugtophobning i <strong>isoleringsmaterialer</strong><br />

Af figurerne i bilag A og tabel 3 til tabel 5 fremgår, at det maksimale fugtindhold<br />

i <strong>isoleringsmaterialer</strong>ne er 16,5 % træfugt. Disse værdier er målt i ydersiden<br />

af isoleringen om vinteren, hvor temperaturen har været lav (mellem 5<br />

og 10 °C).<br />

Selv om der er usikkerhed <strong>på</strong> målingerne og fugtindholdet kan blive højere,<br />

hvis den relativ luftfugtighed i boligerne er højere, har alle konstruktioner,<br />

uanset anvendt isoleringsmateriale, et fugtindhold der ligger under kriteriet<br />

<strong>på</strong> 20 % træ-fugt.<br />

Selv om der er forskel <strong>på</strong> de målte fugtophobninger i de forskellige <strong>isoleringsmaterialer</strong>,<br />

er forskellene ikke signifikante. Middelværdien af fugtindholdet<br />

målt i alle de <strong>alternative</strong> <strong>isoleringsmaterialer</strong> i facaderne er 13,3 % træfugt<br />

og i mineraluld er middelværdien 13,6 % træ-fugt. Der er altså ikke signifikant<br />

forskel mellem middelværdien for fugtophobningen i <strong>alternative</strong> <strong>isoleringsmaterialer</strong><br />

og middelværdien for fugtophobningen i mineralulds baserede<br />

<strong>isoleringsmaterialer</strong>.<br />

Af figurerne i bilag A og tabel 3 til tabel 5 fremgår, at fugtindholdet i facaden,<br />

målt i ydersiden af isoleringen, er lidt højere den første vinter end den<br />

anden vinter. Dette indikerer, at der har været indbygget en vis mængde<br />

byggefugt.


Er isoleringsarbejdet udført korrekt?<br />

For at undersøge om isoleringsarbejdet er udført korrekt, dvs. om isoleringsmaterialet<br />

udfylder det hulrum, der skal isoleres, foretages en termografering<br />

af de indvendige overflader under vinterforhold. Ved termograferingen registreres<br />

de indvendige overfladers temperatur. Lokalt forekommende temperaturforskelle<br />

kan indikere, at isoleringsarbejdet ikke er udført korrekt. Lokalt<br />

forekommende temperaturforskelle kan også skylles kuldebroer som ikke<br />

kan relateres til de isolerede konstruktioner.<br />

Termografering<br />

Overflader med en temperatur over det absolutte nulpunkt (-273 °C) udstråler<br />

varme. Jo varmere overfladen er, desto mere intens er udstrålingen.<br />

Mennesket kan kun se varmen fra overflader med en temperatur <strong>på</strong> mindst<br />

500 °C. Ved bestemmelse af temperaturen <strong>på</strong> overflader, hvor temperaturen<br />

er under 500 °C, kan termografering anvendes, idet udstyret, der anvendes<br />

til termografering, kan "se" varmestråling fra en overflade med meget lavere<br />

temperaturer end det menneskelige øje kan se. Ved termograferingen omsættes<br />

intensiteten af strålingen fra en overflade til en temperatur. Til denne<br />

beregning benyttes en omregningsformel og kendskabet til overfladens<br />

egenskaber for udstråling, også kaldet emissiviteten.<br />

<strong>Måling</strong>er<br />

Termografering kan foretages indefra eller udefra. Selv om bagvægge af letklinkerbeton<br />

til en vis grad vil udjævne lokalt forekommende temperaturforskelle,<br />

er termograferingen i dette projekt foretaget indefra, idet der ikke kan<br />

termograferes udefra, når facaden er udført med en ventileret luftspalte.<br />

Der blev foretaget termografering af alle lejligheder, med undtagelse af de<br />

seks lejligheder i underetagen.<br />

Termografien blev foretaget den 12. og 13. februar 2003, ved ca. -1 °C.<br />

Vejret var stabilt, med nogen sol i løbet af dagen og svag til let vind mest fra<br />

sydøst.<br />

Termograferingen blev foretaget med et AGEMA 570 kamera, der var kalibreret<br />

forud for målingerne. Ved måling med kameraet kræves kendskab til<br />

overfladernes emissivitet samt omgivelsernes temperatur og relative luftfugtighed.<br />

Emissiviteten er valgt til 0,68, som er emissiviteten for hvidt papir,<br />

idet overfladerne i de enkelte lejligheder er hvidmalet tapet. Mørke overflader,<br />

fx mørkt træ og læder, har en anden emissivitet end de hvide vægge.<br />

Dette medfører, at mørke overflader <strong>på</strong> de termografiske billeder vil fremstå,<br />

som om de har en højere temperatur end de hvide overflader. Referanceværdier<br />

for temperatur og relativ luftfugtighed blev indtastet i termograferingsudstyret<br />

ud fra målinger taget <strong>på</strong> stedet.<br />

Resultat af termografering<br />

Ved termograferingen blev der registreret lokalt forekommende temperaturforskelle<br />

mellem lokalt afgrænsede områder og et vægpartis generelle temperatur.<br />

De registrerede lokale temperaturforskelle blev efterfølgende opdelt<br />

i syv kategorier, der er anført i tabel 6.<br />

23


24<br />

Tabel 6. Registrerede lokalt forekommende områder med temperaturforskelle opdelt i syv kategorier.<br />

Kategori<br />

A Kolde overgange mellem lejlighedsskel og loft<br />

B Koldt hjørner mellem lejlighedsskel og facade<br />

C Kolde fodpaneler langs facade<br />

D Kolde områder ved spær, lagt an <strong>på</strong> bagvæg af letklinkerbeton<br />

E Kolde områder i den isolerede facade<br />

F Kolde områder i den isolerede facade langs loftet<br />

G Kolde hjørner mellem lejlighedsskel/gavl, loft og facader<br />

Registreringen af overfladetemperaturer ved termografering sker i form af<br />

termografiske farvebilleder. Billederne er digitale og temperaturen i billedets<br />

enkelte punkter aflæses ved hjælp af et PC baseret program.<br />

I Figur 14 til figur 38 er vist en række eksempler <strong>på</strong> områder, hvor der er<br />

registret lokale temperaturforskelle. Temperaturforskellene forekommer i de<br />

digitale billeder som lokalt afgrænsede områder og dets temperatur sættes i<br />

forhold til den <strong>på</strong>gældende vægs generelle temperatur. Figurerne er grupperet<br />

efter kategori jvf. tabel 6, og for hver kategori er årsagen til temperaturforskellen<br />

søgt belyst, idet nogle temperaturforskelle sandsynligvis skylles<br />

kuldebroer i den valgte konstruktion og andre isoleringsfejl.<br />

I tabel 7 er, for de enkelte <strong>isoleringsmaterialer</strong>, angivet de temperaturforskelle,<br />

der er registret inden for hver kategori. Der er ikke angivet, hvor<br />

mange områder eller hvor store arealer der med den angivede temperaturforskel,<br />

er registreret inden for hver isoleringsmateriale/kategori, fordi der<br />

kan være flere områder med temperaturforskelle end de i tabel 7 opførte,<br />

idet termograferingen ikke var total, da der fx ikke blev flyttet møbler før termograferingen.<br />

Middelværdien af de registrerede temperaturforskelle, inden for hver isoleringsmateriale,<br />

er vist i figur 13. Middelværdien af de registrerede temperaturforskelle<br />

<strong>på</strong> overflader, hvor konstruktionen er isoleret med <strong>alternative</strong><br />

isoleringsmateriale, er 3,4 °C og 3,1 °C når konstruktionen er isoleret med<br />

mineraluld.<br />

Tabel 7. Temperaturforskelle registret ved termografering opdelt efter isoleringsmateriale og kategori jvf.<br />

tabel 6. Temperaturforskelle er differencen mellem den <strong>på</strong>gældende vægs generelle temperatur og den<br />

laveste temperatur i et <strong>på</strong> væggen lokalt afgrænset område. For nogle <strong>isoleringsmaterialer</strong> og/eller kategorier<br />

blev der registreret flere lokalt afgrænsede områder med temperaturer forskellige fra den <strong>på</strong><br />

den øvrige væg. Der er da angivet den laveste og den højeste temperaturforskel. ”-” angiver at der ikke<br />

blev fundet områder med lokalt forekommende temperaturforskelle i den <strong>på</strong>gældende kategori.<br />

Kategori A<br />

°C<br />

B<br />

°C<br />

C<br />

°C<br />

D<br />

°C<br />

E<br />

°C<br />

F<br />

°C<br />

G<br />

°C<br />

Middel<br />

°C<br />

Ekofiber 2,5 2,0 4,3-8,3 0,9-1,5 2,4 3,1-5,4 4,2-5,8 3,4<br />

Isodan 4,9-5,1 1,0 4,7-8,3 1,4-1,5 - 1,6-3,8 2,6-4,9 2,9<br />

Papiruld 5,1 - 2,0-9,0 - - 3,4 5,7 2,8<br />

Thermocell 3,5-4,2 1,3-2,0 4,0-10,6 1,3-1,8 4,2 - 1,8-2,6 3,0<br />

Høruld i formstykker 3,1-5,2 - 5,8-8,8 1,5-3,8 - 2,6 5,3 2,7<br />

Heraflax 4-6,3 - 6,5-12,3 2,3 - 2,5 7,2 3,8<br />

Perlite 5,6 1,7 2,3-6,6 1,0-3,1 - 4,9-8,2 13,6 5,3<br />

Rockwool 4,4-6,5 1,2 0,5-9,3 1,3 - 2,0 3 2,8<br />

Isover 4,4-6,4 1,0-1,3 3,2-6,8 0,8-1,5 4,2 5,3 1,8 3,4


Temperatur [° C]<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

Ekofiber<br />

Isodan<br />

Papiruld<br />

Thermocell<br />

Høruld i f.st.<br />

Heraflex<br />

Perlite<br />

Isover<br />

Rockwool<br />

Figur 13. Middelværdien af de registrerede temperaturforskelle mellem temperaturen i lokalt afgrænsede<br />

områder og temperaturen <strong>på</strong> den øvrige væg <strong>på</strong> indvendige overflader, som funktion af hvilket isoleringsmateriale<br />

konstruktionen er isoleret med.<br />

Bemærkninger til termografering<br />

Kategori A: Kolde overgange mellem lejlighedsskel og loft<br />

Lejlighedsskel dækker dels over de traditionelle lejlighedsskel mellem to ved<br />

siden af hinanden i samme vandrette plan beliggende lejligheder, dels over<br />

længehusenes afsluttende afgrænsning vinkelret <strong>på</strong> facaden, herunder udadgående<br />

hjørner ved husets gavl og indhakket ved længehusenes indgangspartier.<br />

Lejlighedsskellet er opført af 100 mm letklinkerbetonelementer<br />

ført op gennem loftrummet til lige under tagkonstruktionen. Tagrummet er<br />

ventileret og alle de termograferede lejligheder viste sig at have en kold<br />

overgang mellem loftet og lejlighedsskellet eller gavlen i lejlighedens fulde<br />

dybde, se figur 14 og figur 15.<br />

<strong>Måling</strong>erne viser, at denne løsning til brandsektionering af loftrummet<br />

mellem lejlighederne medfører kuldebroer.<br />

Figur 14. Overgang mellem lejlighedsskellene og loft i stue. Lejlighedens loft er isoleret med cellulose i<br />

form af genbrugspapir fra Miljøisolering. På det termografiske billede til venstre repræsenterer farven<br />

rød 23 °C og farven mørkeblå 18 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

25


26<br />

Figur 15. Overgang mellem lejlighedsskel (til venstre) og loft i soveværelse. Lejlighedens loft er isoleret<br />

med mineraluld i form af stenuld fra Rockwool. På det termografiske billede til venstre repræsenterer<br />

farven rød 19 °C og farven mørkeblå 13 °C. Til højre er vist et sædvanligt fotografi taget fra samme<br />

sted.<br />

Kategori B: Kolde hjørner mellem lejlighedsskel og facade<br />

Lejlighedsskel dækker dels over det traditionelle lodrette lejlighedsskel mellem<br />

to ved siden af hinanden i samme vandrette plan beliggende lejligheder<br />

dels over udadgående hjørne ved husets gavl.<br />

Hjørnesamlingen mellem gavl og facade giver traditionelt risiko for små<br />

svært tilgængelige hulrum. Gøres der isoleringsmæssigt ikke noget ekstraordinært<br />

for at isolere i hjørnet mellem facade og gavl vil hjørnet være lidt<br />

koldere end de tilstødende vægflader da netop hjørnet er <strong>på</strong>virket af kulden<br />

fra to sider, se figur 16 og figur 17.<br />

<strong>Måling</strong>erne viser, at hvis der i et byggeri ikke gøres noget ekstraordinært<br />

for varmeteknisk at sikre et velisoleret gavlhjørne, kan det medføre kuldebroer.<br />

Figur 16. Hjørne mellem lejlighedsskel (til venstre) og facade i værelse. Lejlighedens facade er isoleret<br />

med cellulose i form af træfiber fra Thermocell. På det termografiske billede til venstre repræsenterer<br />

farven blå 19 °C og farven rødgul 21 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 17. Hjørne mellem gavl, til højre og facade i soveværelse. Lejlighedens gavl og facade er isoleret<br />

med mineraluld i form af glasuld fra Isover. På det termografiske billede til venstre repræsenterer farven<br />

grøn 17 °C og farven rød 18 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.


Kategori C: Kolde fodpaneler langs facade<br />

Kolde fodpaneler langs facaden blev observeret i alle de termografisk registrerede<br />

lejligheder, hvor den indvendige letklinkerbetonvæg stod <strong>på</strong> fundamentet.<br />

Kolde fodpaneler blev ikke observeret <strong>på</strong> steder med en isoleret facade<br />

nedenunder. Fundamentet består af 300 mm <strong>på</strong> stedet støbt beton, der<br />

er afsluttet med lecablokke. På lecablokkene er bagvæggen af 100 mm letklinkerbetonelementer<br />

opsat. Soklen er pudset udvendigt.<br />

Denne opbygning af fundamentet og samling med bagvæggen har vist<br />

sig at give en væsentlig kuldebro ved fodpanelet inde i lejlighederne, se figur<br />

18 og figur 19. Til sammenligning viser figur 20 et fodpanel langs facaden i<br />

en stue, hvor ydervægsisoleringen er ført forbi etageadskillelsen, kun brudt<br />

af væggens bundrem, idet lejligheden ligger ovenover en tilsvarende lejlighed.<br />

Imellem underetagen og teknikrum er der i hver blok en passage/port, se<br />

figur 3. I lejligheder, der er beliggende over porten, er der observeret kolde<br />

fodpaneler, se figur 21 og figur 22.<br />

<strong>Måling</strong>erne viser en fundamentsløsning samt en løsning over en passage/port,<br />

der varmeteknisk ikke er særlig hensigtsmæssig.<br />

Figur 18. Fodpanel i soveværelse langs facade. På væggen langs facaden er der opsat et varmeapparat.<br />

Lejlighedens facade er isoleret med cellulose i form af genbrugspapir fra Isodan. På det termografiske<br />

billede til venstre repræsenterer farven mørkeblå 12 °C og farven gul 20 °C. Til højre er vist et<br />

sædvanligt fotografi taget fra samme sted.<br />

Figur 19. Fodpanel i stuen langs facade. Op til panelet mod facaden er der lagt et tæppe. Lejlighedens<br />

facade er isoleret med cellulose i form af genbrugspapir fra Isodan. På det termografiske billede til venstre<br />

repræsenterer farven mørkeblå 17 °C og farven rød 24 °C. Til højre er vist et sædvanligt fotografi<br />

taget fra samme sted.<br />

27


28<br />

Figur 20. Fodpanel i stuen langs facade. Lejligheden ligger ovenover en tilsvarende lejlighed og dens<br />

facade er isoleret med mineraluld i form af stenuld fra Rockwool. På det termografiske billede til venstre<br />

repræsenterer farven gul 22 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted. De røde<br />

farver, <strong>på</strong> det termografiske billede, vil normalt repræsentere overflader med en temperatur, der er højere<br />

end de 22 °C, der er målt <strong>på</strong> væggen. Den tilsyneladende højere temperatur skylles, at de mørke<br />

overflader har en anden emissivitet end den, væggen har og som kameraet er indstillet til.<br />

Figur 21. Fodpanel i stue langs facade. Lejlighedens facade er isoleret med plantefibre i form af høruld<br />

fra Heraklith. På det termografiske billede til venstre repræsenterer farven sortblå 10 °C og farven gul<br />

21 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted. Temperaturen <strong>på</strong> væggen over radiatoren<br />

er også 21 °C.<br />

Figur 22. Fodpanel i stue langs facade. Lejlighedens facade er isoleret med mineraluld i form af stenuld<br />

fra Rockwool. På det termografiske billede til venstre repræsenterer farven sortblå 13 °C og farven gul<br />

18 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted. Temperaturen <strong>på</strong> væggen over radiatoren<br />

er også 18 °C.<br />

Kategori D: Kolde områder ved spær, lagt an <strong>på</strong> bagvæg af<br />

letklinkerbeton<br />

Termografiske observationer af overgangen mellem facade og loft viser<br />

spærfodens kontaktpunkt med bagvæggen af letklinkerbeton som regelmæssige<br />

punktformede vel afgrænsede områder med temperaturforskelle<br />

<strong>på</strong> loft og væg. Afhængigt af hvor omhyggelig isoleringsarbejdet er udført<br />

omkring spærfoden vil de regelmæssige punktformede områder med temperaturforskelle<br />

i en omegn <strong>på</strong> loft og væg mod facaden være mere eller mindre<br />

vel afgrænsede, se figur 23 og figur 24.


<strong>Måling</strong>erne viser den varmetekniske konsekvens af at lægge spærfoden<br />

an mod bagvæggen af letklinkerbeton.<br />

Figur 23. Overgang mellem loft og facade i soveværelse. Lejlighedens loft og facade er isoleret med et<br />

mineralsk granulat i form af perlit fra Nordisk Perlite. På det termografiske billede til venstre repræsenterer<br />

farven gul 17 °C og farven mørkeblå 14 °C. Til højre er vist et sædvanligt fotografi taget fra samme<br />

sted.<br />

Figur 24. Overgang mellem loft og facade i stue. Lejlighedens loft og facade er isoleret med mineraluld i<br />

form af stenuld fra Rockwool. På det termografiske billede til venstre repræsenterer farven gul 23 °C og<br />

farven blå 21 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Kategori E: Kolde områder i den isolerede facade<br />

Kolde områder i den isolerede facade blev observeret i alle lejligheder under<br />

termograferingen. Under databehandlingen af de termograferede lejligheder<br />

blev der skelnet mellem lokalt afgrænsede kolde områder og kolde områder<br />

ved loft. Lokalt afgrænsede kolde områder i den isolerede facade blev observeret<br />

i nogle lejligheder under termograferingen. Områderne repræsenterer<br />

kuldebroer i facaden og viser sig <strong>på</strong> den indvendige side af det 100 mm<br />

tykke letklinkerbetonelement som afgrænsede kolde områder, se figur 25 til<br />

figur 27.<br />

<strong>Måling</strong>erne viser den varmeteknisk konsekvens af inhomogen varmeisolering<br />

af facaden. I afsnittet Beregning af hulrum er der, ved hjælp af et PCprogram<br />

til beregning af varmestrøm, beregnet, hvor stor inhomogenitet, der<br />

skal være i isoleringen for at give de målte temperaturforskelle.<br />

29


30<br />

Figur 25. Facade mellem vindue og øvre køkkenskabe i køkken. Lejlighedens facade er isoleret med<br />

cellulose i form af genbrugspapir fra Ekofiber. På det termografiske billede til venstre repræsenterer farven<br />

rød 20 °C, gul 19,6 °C og farven mørkeblå 17 °C. Til højre er vist et sædvanligt fotografi taget fra<br />

samme sted. Køkkenskabet ses i højre side af billedet.<br />

Figur 26. Facade under øvre køkkenskabe i køkken. Lejlighedens facade er isoleret med mineraluld i<br />

form af glasuld fra Isover. På det termografiske billede til venstre repræsenterer farven gul 19 °C og farven<br />

mørkeblå 14 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 27. Facade mellem to vinduer i stuen. Lejlighedens facade er isoleret med Cellulose i form af træfiber<br />

fra Thermocell. På det termografiske billede til venstre repræsenterer farven gul 21 °C og farven<br />

mørkeblå 16 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Kategori F: Kolde områder i den isolerede facade langs loftet<br />

Kolde områder i den isolerede facade langs overgangen mellem facaden og<br />

loftet blev observeret i de fleste lejligheder under termograferingen. Områderne<br />

repræsenterer kuldebroer i konstruktionen og viser sig <strong>på</strong> den indvendige<br />

side af det 100 mm tykke letklinkerbetonelement som et afgrænset<br />

koldt område, se figur 28 til figur 36. Samlingen mellem loft og facade giver<br />

risiko for små svært tilgængelige hulrum som kan give anledning til en kuldebro.<br />

Ved isolering af overgangen mellem facaden og loftet er det nødvendigt<br />

at sikre sig, at isoleringen ikke glider fra hinanden, samt at isoleringen<br />

samles så tæt, at kold luft ikke kan passere ind <strong>på</strong> den varme side af isoleringen.<br />

<strong>Måling</strong>erne viser den varmetekniske konsekvens af at isoleringen i facaden<br />

langs loftet er varmeledningsmæssig inhomogen. I afsnittet Beregning<br />

af hulrum er der, ved hjælp af et PC-program til beregning af varmestrøm,


eregnet, hvor store inhomogenitet der skal være i isoleringen, for at give de<br />

målte temperaturforskelle.<br />

Figur 28. Overgang mellem loft og facade i stue. Lejlighedens loft og facade er isoleret med cellulose i<br />

form af genbrugspapir fra Ekofiber. På det termografiske billede til venstre repræsenterer farven rød 20<br />

°C, gul 19 °C og mørkeblå 16 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 29. Overgang mellem loft og facade i stue. Lejlighedens loft og facade er isoleret med cellulose i<br />

form af genbrugspapir fra Ekofiber. På det termografiske billede til venstre repræsenterer farven rød 20<br />

°C, gul 19 °C og mørkeblå 14 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 30. Overgang mellem loft og facade i stue. I denne lejlighed er facaden vinklet. Lejlighedens loft<br />

og facade er isoleret med cellulose i form af genbrugspapir fra Isodan. På det termografiske billede til<br />

venstre repræsenterer farven gul 22 °C, grøn 20 °C og mørkeblå 17 °C. Til højre er vist et sædvanligt<br />

fotografi taget fra samme sted.<br />

31


32<br />

Figur 31. Overgang mellem loft og facade i soveværelse. Lejlighedens loft og facade er isoleret med<br />

cellulose i form af genbrugspapir fra Miljøisolering. På det termografiske billede til venstre repræsenterer<br />

farven gul 14 °C og mørkeblå 10 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 32. Overgang mellem loft og facade i soveværelse. Lejligheden er isoleret med mineraluld i form<br />

af glasuld fra Isover. På det termografiske billede til venstre repræsenterer farven gul 20 °C og blå 14<br />

°C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 33. Overgang mellem loft og facade i stue. Lejlighedens loft og facade er isoleret med plantefibre i<br />

form af høruld fra Dansk Naturisolering. På det termografiske billede til venstre repræsenterer farven<br />

grøn 20 °C og mørkeblå 17 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 34. Overgang mellem loft og facade i soveværelse. Lejlighedens loft og facade er isoleret med<br />

plantefibre i form af høruld fra Heraklith. På det termografiske billede til venstre repræsenterer farven<br />

gul 19 °C og mørkeblå 16 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.


Figur 35. Overgang mellem loft og facade i kontor. Lejlighedens loft og facade er isoleret med et mineralsk<br />

granulat i form af perlit fra Nordisk Perlite. På det termografiske billede til venstre repræsenterer<br />

farven gul 22 °C og mørkeblå 17 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Figur 36. Overgang mellem loft og facade i stue. Lejlighedens loft og facade er isoleret med mineraluld i<br />

form af stenuld fra Rockwool. På det termografiske billede til venstre repræsenterer farven gul 22 °C og<br />

blå 20 °C. Til højre er vist et sædvanligt fotografi taget fra samme sted.<br />

Kategori G: Kolde hjørner ved lejlighedsskel/gavl, loft og facade<br />

Kolde områder i hjørnet ved lejlighedsskel/gavl, loft og facade blev observeret<br />

i alle lejlighederne under termograferingen. Områderne repræsenterer<br />

kuldebroer i konstruktionen og viser sig <strong>på</strong> den indvendige side af det 100<br />

mm tykke letklinkerbetonelement som et afgrænset koldt område, se figur 37<br />

og figur 38. Samlingen ved lejlighedsskel/gavl, loft og facade giver risiko for<br />

små svært tilgængelige hulrum som derved kan give anledning til en introduceret<br />

kuldebro.<br />

<strong>Måling</strong>erne viser den varmetekniske konsekvens af varmeledningsmæssig<br />

inhomogenitet i isoleringen i hjørnet ved lejlighedsskel/gavl, loft og facade.<br />

Figur 37. Hjørne i køkken med lejlighedsskel til højre og facade til venstre. Lejlighedens loft og facade er<br />

isoleret med plantefibre i form af høruld fra Heraklith. På det termografiske billede til venstre repræsenterer<br />

farven rød 22 °C og farven mørkeblå 14 °C. Til højre er vist et sædvanligt fotografi taget fra samme<br />

sted.<br />

33


34<br />

Figur 38. Hjørne i kontor med facade til venstre og gavl til højre. Lejlighedens loft og facade er isoleret<br />

med et mineralsk granulat i form af perlit fra Nordisk Perlite. På det termografiske billede til venstre repræsenterer<br />

farven gul 21 °C og mørkeblå 8 °C. Til højre er vist et sædvanligt fotografi taget fra samme<br />

sted.<br />

Diskussion<br />

For at undersøge om isoleringsarbejdet er udført korrekt, dvs. om isoleringsmaterialet<br />

udfylder det hulrum, der skal isoleres, er der foretaget en termografering<br />

af de indvendige overflader under vinterforhold. Ved termograferingen<br />

registreres de indvendige overfladers temperatur og dermed lokalt<br />

forekommende afgrænsede områder med en temperatur forskellig fra temperaturen<br />

<strong>på</strong> den øvrige væg.<br />

Af tabel 7 fremgår at de registrerede temperaturforskelle varierer efter<br />

isoleringsmateriale og efter kategori. For at kunne foretage en sammenligning<br />

af <strong>isoleringsmaterialer</strong>ne, er middelværdien af lokalt forekommende<br />

temperaturforskelle beregnet for de enkelte <strong>isoleringsmaterialer</strong> og vist i<br />

figur 13.<br />

På overflader af konstruktioner, der er isoleret med <strong>alternative</strong> <strong>isoleringsmaterialer</strong>,<br />

er middelværdien af de registrerede temperaturforskelle 3,4 °C<br />

mod 3,1 °C <strong>på</strong> overflader af konstruktioner, der er isoleret med mineraluld.<br />

Middelværdien af de registrerede lokalt forekommende temperaturforskelle<br />

<strong>på</strong> overflader af konstruktioner, der er isoleret med det mineralske granulat,<br />

Perlite fra Nordisk Perlite lidt højere end middelværdierne for de øvrige <strong>isoleringsmaterialer</strong>.<br />

Middelværdien af de registrerede temperaturforskelle <strong>på</strong><br />

overflader af konstruktioner, der er isoleret med andre <strong>alternative</strong> <strong>isoleringsmaterialer</strong><br />

end Perlite er 3,1 °C.<br />

Selv om der er forskelle <strong>på</strong> de registrerede lokalt forekommende temperaturforskelle<br />

kan der ud fra de her refererede målinger ikke konstateres signifikante<br />

forskelle mellem temperaturforskelle <strong>på</strong> overflader af konstruktioner,<br />

der er isoleret med <strong>alternative</strong> <strong>isoleringsmaterialer</strong> og temperaturforskelle<br />

<strong>på</strong> overflader af konstruktioner, der er isoleret med mineraluld.<br />

Årsag til lokalt forekommende temperaturforskelle<br />

Årsagen til lokalt forekommende temperaturforskelle kan ikke med sikkerhed<br />

angives, uden at der foretages en destruktiv undersøgelse af konstruktionerne.<br />

Oprindeligt var det hensigten, at der skulle foretages termografiske<br />

observationer af de isolerede bygningsdele, umiddelbart efter at bygningsdelene<br />

var blevet isoleret. Hensigten med disse observationer var, sammenholdt<br />

med de senere termografiske observationer, at kunne skelne mellem<br />

hulrum opstået over tid og hulrum introduceret under isoleringsarbejdet. De<br />

termografiske observationer kræver temperaturfald over isoleringen, som<br />

opnås i vinterhalvåret. Da bebyggelsens isoleringsarbejde strakte sig over<br />

en periode ud over vinterhalvåret, ville nogle bygningsdele først kunne termograferes<br />

den efterfølgende vinter. På det tidspunkt ville hensigten med de<br />

første termografiske observationer ikke længere være til stede, da konstruktionerne<br />

dermed ikke var isoleret for nyligt. De termografiske observationer<br />

blev derfor ikke foretaget af de isolerede bygningsdele umiddelbart efter, at


ygningsdelene var blevet isoleret. Lokalt forekommende temperaturforskelle<br />

kan indikere følgende:<br />

– der er kuldebroer (som ikke er relaterede til de isolerede konstruktioner)<br />

– isoleringsarbejdet er ikke udført korrekt<br />

– der er efterfølgende sket sætninger i isoleringen.<br />

Der er øjensynligt væsentlige kuldebroer ved:<br />

– Fodpaneler langs facaden.<br />

– Overgangen mellem lejlighedsskel og loft.<br />

Der er øjensynligt mindre kuldebroer ved:<br />

– Spær lagt an <strong>på</strong> bagvæg.<br />

– Hjørner mellem lejlighedsskel/gavl og facade.<br />

Isoleringsarbejdet er øjensynligt ikke udført korrekt eller der er sket sætninger<br />

af isoleringen:<br />

– I lokale område i facaden.<br />

– I facaden langs loftet.<br />

Beregning af hulrum<br />

For at få et indtryk af isoleringsfejlene og/eller sætningerne, er der foretaget<br />

beregning af, hvor store hulrum der skal være i isoleringen, for at give de registrerede<br />

lokale temperaturforskelle.<br />

Beregningerne er gennemført med et kommercielt program HEAT 2, version<br />

5.0 (Lunds Universitet, 2002) til beregning af todimensionale varmestrømme<br />

svarende til at geometrien er fuldt bestemt ved det valgte tværsnit.<br />

HEAT 2 er et PC-baseret program til beregning af todimensional varierende<br />

eller stabile varmestrømme. PC programmets beregninger gennemføres i<br />

overensstemmelse med standarden ISO 10211-1 (International Organization<br />

for Standardization, 1995).<br />

Varmestrømsberegning<br />

Beregningerne er gennemført ved at opbygge en model af den anvendte<br />

konstruktion med de rette dimensioner og materialer. Varmeledningsevnen<br />

er for <strong>isoleringsmaterialer</strong> sat til 0,039 W/mK, idet dette skønnes at give en<br />

bedre overensstemmelse med de termografiske registreringer end de i tabel<br />

2 angivne værdier, der er med diverse tillæg. Da programmet kun kan beregne<br />

todimensionale varmestrømme er træstolperne i facaden og spærene<br />

i tagkonstruktionen ikke medtaget i modellen. De i modellen anvendte materialer,<br />

dimensioner og varmeledningsevner er vist i tabel 8. Modellen er opbygget<br />

med en indvendig væghøjde <strong>på</strong> 2,4 m og med en indvendig loftlængde<br />

<strong>på</strong> 1,5 m.<br />

35


36<br />

Tabel 8. Varmeledningsevne og tykkelse for de enkelte materialer anvendt i model til todimensionale<br />

beregninger af varmestrøm gennem facade og loft isoleret med Ekofiber. Varmeledningsevnen er for<br />

(alle) <strong>isoleringsmaterialer</strong> valgt til 0,039 W/mK, idet det skønnes at give en bedre overensstemmelse<br />

med de termografiske registreringer end de i tabel 2 angivne værdier, der er med diverse tillæg.<br />

Materialer Varmeledningsevne<br />

W/mK<br />

Tykkelse<br />

mm<br />

Træbeklædning 0,16 24<br />

Ventileret hulrum 0,24 22<br />

Vindgips 0,17 9<br />

Isolering i facade 0,039 200<br />

Letklinkerbetonelement 0,9 100<br />

Gips 0,17 26<br />

loftisolering 0,039 415<br />

Figur 39 viser grafisk den opbyggede model af facaden og samlingen mellem<br />

facaden og loftkonstruktionen. Modellen er vist med korrekt placeret facade-<br />

og loftisolering og med en ubrudt samling af facade- og loftisolering. I<br />

byggeriet er der anvendt facadekonstruktioner med toprem, men i de undersøgte<br />

konstruktioner er topremmen åbnet ved gennemsavning eller helt fjernet.<br />

I figur 40 er vist den tilsvarende grafiske model af facaden og samlingen<br />

mellem facaden og loftkonstruktionen, men med en toprem i facaden.<br />

Figur 39. Model til beregning af varmestrøm gennem facade og samlingen mellem facade og loftkonstruktion<br />

med korrekt placeret isolering. Modellens dimensioner er angivet i tabel 8.


Figur 40. Detalje af model til beregning af varmestrøm gennem samlingen mellem facade og loftkonstruktion<br />

med korrekt placeret isolering og med en toprem, se i øvrigt figur 39.<br />

Beregning af hulrum i facade isoleret med Ekofiber<br />

Med udgangspunkt i Kategori E: Kolde områder i den isolerede facade beregnes<br />

det ækvivalente hulrum som resulterer i de ved termografien registrerede<br />

lokalt forekommende temperaturforskelle. Hulrummet i isoleringen antages<br />

at være et luftfyldt rektangulært hulrum. Tabel 9 viser anvendte værdier<br />

til beregning af hulrummet. Ved beregningen er det forudsat, at der ikke er<br />

nogen varmestrøm gennem de afgrænsede snit vinkelret <strong>på</strong> facadens plan.<br />

Tabel 9. Parametre og anvendte værdier til beregning af et ækvivalent hulrum i isoleringen i en facade.<br />

Parameter Værdi med enhed<br />

Temperaturen ude -1 ° C<br />

Overgangsisolans ude 0,04 m2K/W Luftens varmekapacitet 1,239 kJ/(m3K) Luftskiftet 0 gange i timen<br />

Emissivitet til hulrummets 4 sider 0,9<br />

Konvektionskoefficienten 3 W/(m2K) Referencetemperaturen 10 °C<br />

Overgangsisolans inde (facade) 0,13 m2K/W Overgangsisolans inde (loft) 0,10 m2K/W Temperaturen inde 20 °C<br />

Figur 41 viser resultaterne af en varmestrømsberegning i en facade med et<br />

idealiseret hulrum i isoleringen. Hulrummet er <strong>på</strong> figur 41 angivet med symbolet<br />

1:1, og har en højde <strong>på</strong> 300 mm i hele isoleringens tykkelse. Hulrummet<br />

er beregnet ud fra det kriterium, at temperaturen <strong>på</strong> den indvendige<br />

vægoverflade i et lokalt afgrænset område skal være 2,4 °C lavere end temperaturen<br />

<strong>på</strong> den øvrige facadeindervæg, når der er isoleret med Ekofiber,<br />

jf. tabel 7. Hulrummets højde er fundet ved at foretage en varmestrømsbe-<br />

37


38<br />

regning med en gættet højde og derefter gentage beregningen med nye<br />

højder indtil den ønskede temperaturforskel er opnået.<br />

Figur 41. Temperaturforløb i facade med et idealiseret hulrum i isoleringen. Hulrummet, som er idealiseret<br />

ved at være rektangulært, er angivet med symbolet 1:1 og har en beregnet højde <strong>på</strong> 300 mm i hele<br />

isoleringens tykkelse. Hulrummets højde er beregnet ud fra det kriterium, at temperaturen <strong>på</strong> den indvendige<br />

vægoverflade, i et lokalt afgrænset område, skal være 2,4 °C lavere end temperaturen <strong>på</strong> den<br />

øvrige facadeindervæg, når der er isoleret med Ekofiber, jf. tabel 7. På figuren er temperaturfeltet omkring<br />

isotermen som repræsenterer 17 °C fremhævet med farven hvid (temperaturen <strong>på</strong> den indvendige<br />

vægoverflader <strong>på</strong> 19,4 °C minus temperatusænkningen <strong>på</strong> 2,4 °C).<br />

Temperatur ved overgangen mellem facade og loft<br />

Da overgangen mellem facade og loft er <strong>på</strong>virket af kulde fra to sider er det<br />

velkendt, at overgangen kan have en temperatur, der er lavere end temperaturen<br />

<strong>på</strong> tilstødende vægge og lofter. Den forventede lokale temperaturforskel<br />

i overgangen mellem facade og loft er beregnet med og uden toprem<br />

placeret langs letbetonelementets øvre kant for at vurdere topremmens indflydelse<br />

<strong>på</strong> den lokale temperaturforskel.<br />

Figur 42 og figur 43 viser resultaterne af en varmestrømsberegning af<br />

overgangen mellem facade og loft, henholdsvis med og uden en toprem<br />

øverst i facadeelementet. De til beregningen anvendte værdier er vist i tabel<br />

9. Ved beregningen er det forudsat at der ikke er nogen varmestrøm gennem<br />

de afgrænsende snit vinkelret <strong>på</strong> facadens plan.


Figur 42. Temperaturforløb i facade, loft og overgangen mellem facade og loft i en konstruktion med<br />

toprem. Topremmen har en højde <strong>på</strong> 45 mm. Temperaturen <strong>på</strong> midten af den indvendige vægoverflade<br />

er 19,5 °C. Temperaturen <strong>på</strong> den indvendige vægoverflade i overgangen mellem facadeelementet og<br />

loftet er 18,7 °C.<br />

Figur 43. Temperaturforløb i facade, loft og overgangen mellem facade og loft i en konstruktion uden<br />

toprem. Temperaturen <strong>på</strong> midten af den indvendige vægoverflader er 19,5 °C. Temperaturen <strong>på</strong> den<br />

indvendige vægoverflade i overgangen mellem facadeelementet og loftet er 19 °C.<br />

Beregning af hulrum langs loft i facaden isoleret med Ekofiber<br />

Med udgangspunkt i Kategori F: Kolde områder i den isolerede facade langs<br />

loftet beregnes det ækvivalente hulrum, i den isolerede del af facadekonstruktionen,<br />

som resulterer i de ved termografien registrerede lokale temperaturforskelle.<br />

Da forskellen <strong>på</strong> temperaturen <strong>på</strong> overgangen mellem facade<br />

og loft i konstruktion med og uden toprem kun er 0,3 °C, er der kun foretaget<br />

beregninger <strong>på</strong> konstruktioner uden toprem. Hulrummet i isoleringen anta-<br />

39


40<br />

ges at være et luftfyldt firkantet hulrum. Tabel 9 viser anvendte værdier til<br />

beregning af hulrummet. Ved beregningen er det forudsat at der ikke er nogen<br />

varmestrøm gennem de afgrænsende snit vinkelret <strong>på</strong> facadens plan.<br />

Figur 44 viser resultaterne af en varmestrømsberegningen omkring overgangen<br />

mellem facade og loft i en konstruktion uden toprem med et idealiseret<br />

hulrum i isoleringen. Hulrummet er <strong>på</strong> figur 44 angivet med symbolet 1:1<br />

og har en højde <strong>på</strong> 200 mm i hele isoleringens tykkelse. Hulrummet er beregnet<br />

ud fra det kriterium, at temperaturen i overgangen mellem facade og<br />

loft skal være 3,4 °C lavere end temperaturen <strong>på</strong> facadeindervæggen. Hulrummets<br />

højde er fundet ved at foretage en varmestrømsberegning med en<br />

gættet højde og derefter gentage beregningen med nye højder indtil den ønskede<br />

temperaturforskel er opnået.<br />

Figur 44. Temperaturforløb i facade, loft og overgangen mellem facade og loft i en konstruktion uden<br />

toprem med et idealiseret hulrum i isoleringen. Hulrummet, som er idealiseret ved at være rektangulært,<br />

er angivet med symbolet 1:1 og har en beregnet højde <strong>på</strong> 200 mm i hele isoleringens tykkelse. Hulrummets<br />

højde er beregnet ud fra det kriterium, at temperaturen <strong>på</strong> overgangen mellem facade og loft<br />

skal være 3,4 °C lavere end temperaturen <strong>på</strong> facadeindervægen. På figuren er temperaturfeltet omkring<br />

isotermen som repræsenterer 16 °C fremhævet med farven hvid (temperaturen <strong>på</strong> den indvendige<br />

vægoverflader <strong>på</strong> 19,4 °C minus temperaturforskellen <strong>på</strong> 3,4 °C).<br />

Beregnede hulrum<br />

Analog til beregningerne af de ækvivalente hulrum i konstruktioner isoleret<br />

med Ekofiber, er hulrum i konstruktioner isoleret med de øvrige <strong>isoleringsmaterialer</strong><br />

beregnet. Resultaterne er angivet i tabel 10. Der er beregnet hulrum<br />

for to kategorier: Kolde områder i den isolerede facade (Kategori E) og<br />

Kolde områder i den isolerede facade langs loftet (Kategori F).<br />

Da programmet, der er anvendt til beregningerne bygger <strong>på</strong> todimensionale<br />

varmestrømme, og varmestrømmene er mere eller mindre tredimensionale,<br />

vil programmet ikke altid give realistiske størrelse <strong>på</strong> de ækvivalente<br />

hulrum.


Tabel 10. Højden <strong>på</strong> idealiserede hulrum i isoleringen. Hulrummenes højde er beregnet ud fra det kriterium,<br />

at hulrummet skal resultere i en temperaturforskel <strong>på</strong> den indvendige vægoverflade, der svarer til<br />

de ved termografering registrerede temperaturforskelle, se tabel 7.<br />

Højde af ækvivalent hulrum<br />

kategori E<br />

mm<br />

Højde af ækvivalente hulrum<br />

kategori F<br />

mm<br />

Ekofiber 120 150-500<br />

Isodan - 36-450<br />

Papiruld - 225<br />

Thermocell 1000 -<br />

Høruld i formstykker - 65<br />

Heraflax - 55<br />

Perlite - 800<br />

Rockwool - 35<br />

Isover 1000 800<br />

Manglende isolering<br />

De beregnede ækvivalente hulrum er beregnet ud fra et modelleret tværsnit i<br />

facade og loft konstruktionen. I beregningerne indgår tal for varmeledningsevne<br />

for de anvendte materialer som konstruktionen er opbygget af. De anvendte<br />

tal for varmeledningsevne er ikke målte værdier. Beregningerne er<br />

derfor vejledende og kan kun bruges som en indikation af hvor stort et hulrum,<br />

der må kunne forventes i den isolerede del af konstruktionen.<br />

Hulrum kan opstå i den isolerede del af konstruktionen enten ved at isoleringsmaterialet<br />

er blevet inhomogent fordelt i forbindelse med udførelsen af<br />

arbejdet eller såfremt isoleringsmaterialet med tiden sætter sig eller kryber.<br />

41


42<br />

Litteratur<br />

Andersen T., Fynholm P., Hjorslev Hansen M., Nicolajsen A. (2002). Fugtsikre<br />

træfacader. Fugtindhold i højisolerede træfacader. (By og Byg Dokumentation<br />

025). Hørsholm: <strong>Statens</strong> Byggeforskningsinstitut.<br />

Andersen, N. E., Christensen, G. og Nielsen, F. (1993). Bygningers fugtisolering<br />

(SBI-anvisning 178). Hørsholm: <strong>Statens</strong> Byggeforskningsinstitut.<br />

Boligministeriet (1995). Bygningsreglement 1995. København.<br />

Brandt, E., Hjorslev Hansen, M., Hommel Hansen, O., & Mossing, P. (1998).<br />

<strong>Måling</strong> af træfugt ved modstandsmåling. Byggeindustrien, 49(5), 26-30.<br />

Breum, N. O., Schneider, T., Flyvholm, M,. Jørgensen, O,. Valdbjørn Rasmussen,<br />

T,. & Skibstrup Eriksen, S. (2002) Luftforureninger ved anvendelse<br />

af <strong>alternative</strong> <strong>isoleringsmaterialer</strong>. (Ami Rapport 57) København: Arbejdsmiljø<br />

Instituttet, & <strong>Statens</strong> Byggeforskningsinstitut.<br />

Dansk Ingeniørforening. (1986). Dansk Ingeniørforenings regler for beregning<br />

af bygningers varmetab (5. udg.) (Dansk Standard – DS 418 = Normstyrelsens<br />

publikationer NP-186-S). København: Teknisk Forlag.<br />

Dansk Standard. (2000). Tillæg 2 til DS 418, beregning af bygningers varmetab:<br />

Tillæg omhandlende løsfyldsprodukter (DS 418/Til.2). København.<br />

International Organization for Standardization (1995). 10211-1:1995 Thermal<br />

bridges in building construction – Heat flows and surface temperatures –<br />

Part 1: General calculation methods.<br />

Lund-Hansen, P. (1967). Fugttransport i byggematerialer (Meddelelse nr.<br />

15). Danmarks Tekniske Højskole, Laboratoriet for Varmeisolering. Lyngby:<br />

Polyteknisk Forlag.<br />

Lunds Universitet, Dept. Of Building Physics, Lund Group for Computational<br />

Building Physics. (2002). HEAT2 (version 5.0). Lund. [PC-program].<br />

Nevander, L. E. og Elmersson, B. (1994). Fukthandbok: Praktik och teori.<br />

Stockholm: Svensk Byggtjänst.<br />

Rasmussen, T. V. og Feilberg Hansen K. (2004). Praktiske erfaringer med<br />

<strong>alternative</strong> <strong>isoleringsmaterialer</strong> (By og Byg Resultater 036). Hørsholm: <strong>Statens</strong><br />

Byggeforskningsinstitut.<br />

Stang, B. D. (2002). Fugtforhold i træfacader med letbeton bagvægge. (By<br />

og Byg Dokumentation 033). Hørsholm: <strong>Statens</strong> Byggeforskningsinstitut.<br />

Valbjørn, O. (2003). Undersøgelse og vurdering af fugt og skimmelsvampe i<br />

bygninger. By og Byg anvisning 204. Hørsholm: <strong>Statens</strong> Byggeforskningsinstitut.


Summary<br />

By og Byg Documentation 058: Measurements of <strong>alternative</strong> insulating<br />

materials<br />

Onsite observations of moisture and temperature distribution in 9 different<br />

insulation materials<br />

Tests were made of the performance of 9 different materials used for thermal<br />

insulation in walls and attics on site. The materials included both loosefill<br />

materials and materials of a fixed shape, see Table 1. The assessment of<br />

the performance was based on thermographic observations and measurements<br />

of temperature and moisture conditions within the different materials<br />

used.<br />

The investigation covered two, in principle, identical observations of each<br />

material used for thermal insulation in two apartments. Measuring points<br />

were placed at identical locations in walls and attics in all apartments included<br />

in the investigation. The investigation covered a real-life situation<br />

where the inhabitants and normal weather conditions influenced the thermal<br />

insulation.<br />

Moisture conditions at the warm side and cold side of the materials, used<br />

for thermal insulation, were observed in the insulation material in the wall<br />

cavity and attics. Moisture measuring dowels of wood were used for these<br />

observations. For exterior walls the warm side faced the lightweight concrete<br />

wall that served as the load bearing constructional inner wall. The cold side<br />

of the exterior walls faced the wind barrier made of gypsum.<br />

All the moisture measurement results are expressed as wood moisture<br />

content (weight-%), so that the results can be compared with the danger<br />

zone of 20 % for dry-rot attack in timber. The moisture content within the<br />

material used for thermal insulation was recorded twice a day, at noon and<br />

at midnight. The external and the internal temperature, together with the external<br />

and internal relative humidity, were recorded once every 2 hours.<br />

Moisture accumulation for materials used for thermal insulation<br />

Observations of the moisture conditions within the materials used for thermal<br />

insulation showed no sign of moisture problems for the materials and construction<br />

used. The observed moisture content for the individual materials<br />

was below 20 % (wood moisture). However, the observed moisture content<br />

showed the presence of moisture related to the construction period.<br />

The individual materials, in exterior walls and attics, were influenced by<br />

environmental conditions, described by temperature and relative humidity<br />

related to a normal use of the apartments.<br />

Thermographic observations<br />

Thermographic observations of the insulated exterior walls and building<br />

parts showed a number of thermal bridges. The most important thermal<br />

bridges were related to the architectural design of the building. The two most<br />

important thermal bridges were observed at 1) the joint between foundation,<br />

the slab on the ground and the lightweight concrete wall serving as the load<br />

bearing inner wall, 2) the fire separation of the attic room between apartments<br />

and the apartment boundary. Observations also revealed, that for<br />

some of the insulated walls local areas were discovered with a lower temperature<br />

than seen for the overall wall, those indicating local pockets within<br />

43


44<br />

the insulated areas. Furthermore, it is shown that for some of the insulated<br />

walls, local areas towards the ceiling were discovered to have a lower temperature<br />

than the overall wall, indicating that settling or cold air was able to<br />

reach the inner wall. However, a minor temperature decrease was expected<br />

as the location had low temperature action from two sides, from the attic and<br />

the facade, respectively. One product could not be kept within the wall cavity,<br />

and larger areas were found to have a lower temperature than the overall<br />

wall.<br />

Suitable thermal insulation materials and specific design requirements<br />

Materials used for thermal insulation in walls and attics should meet the following<br />

performance requirements (i) acceptable thermal characteristics, (ii)<br />

ability to be handled on site, and (iii) performance staying the same during<br />

the acknowledged time compared with the lifetime of the construction. For<br />

the material to be able to maintain its performance, it has to keep its thermal<br />

characteristics and fill out the volume as intended. Former observations<br />

have shown that the described materials can be used on site. However,<br />

specifications to describe the tightness of the cavity intended to hold the<br />

materials were found to be needed together with quality assurance. Specifications<br />

to describe the tightness of the individual wall cavity has to be described<br />

on the basis of the characteristics of the material that the cavity is<br />

intended to hold.


Bilag A Temperatur og fugt i facade- og<br />

loftkonstruktioner<br />

Fugtindholdet er angivet som massepct. = vægtpct. fugt i træ, dels fordi<br />

fugtindholdet er målt med trædyvler, dels for umiddelbart at kunne sammenligne<br />

med faregrænsen for vækst af råd og trænedbrydende svampe <strong>på</strong> træ.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

Lejlighed A 1.1, Thermocell, Loft<br />

0<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 45. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af træfiber. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed A 1.1, Thermocell, Facade mod V<br />

-5<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod det fri Værelse, V, øvre mod boligen<br />

Stue, nedre mod det fri Stue, nedre mod boligen<br />

Stue, øvre mod det fri Stue, øvre mod boligen<br />

Figur 46. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af træfiber.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

45


46<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed A 1.1, Thermocell, Facade mod Ø<br />

-5<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 47. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af træfiber.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Fugtindhold [masse-%]<br />

Lejlighed A 1.1, Thermocell, Loft<br />

15,00<br />

14,50<br />

14,00<br />

13,50<br />

13,00<br />

12,50<br />

12,00<br />

11,50<br />

11,00<br />

10,50<br />

10,00<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 48. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af træfiber. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed A 1.1, Thermocell, Facade mod V<br />

10,0<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod det fri Værelse, V, øvre mod boligen<br />

Stue, nedre mod det fri Stue, nedre mod boligen<br />

Stue, øvre mod det fri Stue, øvre mod boligen<br />

Figur 49. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af træfiber.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.


Fugtindhold [masse-%]<br />

18,00<br />

17,00<br />

16,00<br />

15,00<br />

14,00<br />

13,00<br />

12,00<br />

11,00<br />

Lejlighed A 1.1, Thermocell, Facade mod Ø<br />

10,00<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 50. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af træfiber.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

Lejlighed A 1.2, Thermocell, Loft<br />

0<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 51. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af træfiber. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed A 1.2, Thermocell, Facade mod V<br />

-5<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod det fri Værelse, V, øvre mod boligen<br />

Stue, nedre mod det fri Stue, nedre mod boligen<br />

Stue, øvre mod det fri Stue, øvre mod boligen<br />

Figur 52. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af træfiber.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

47


48<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed A 1.2, Thermocell, Facade mod Ø<br />

-5<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri Bad, nedre mod boligen<br />

Bad, øvre mod det fri Bad, øvre mod boligen<br />

Køkken, nedre mod det fri Køkken, nedre mod boligen<br />

Køkken, øvre mod det fri Køkken, øvre mod boligen<br />

Figur 53. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af træfiber.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Fugtindhold [masse-%]<br />

15,0<br />

14,5<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed A 1.2, Thermocell, Loft<br />

10,0<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 54. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af træfiber. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed A 1.2, Thermocell, Facade mod V<br />

10,0<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod det fri Værelse, V, øvre mod boligen<br />

Stue, nedre mod det fri Stue, nedre mod boligen<br />

Stue, øvre mod det fri Stue, øvre mod boligen<br />

Figur 55. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af træfiber.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.


Fugtindhold [masse-%]<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed A 1.2, Thermocell, Facade mod Ø<br />

10,0<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri Bad, nedre mod boligen<br />

Bad, øvre mod det fri Bad, øvre mod boligen<br />

Køkken, nedre mod det fri Køkken, nedre mod boligen<br />

Køkken, øvre mod det fri Køkken, øvre mod boligen<br />

Figur 56. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af træfiber.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed A 1.3, HBC-Hør, Loft<br />

-5<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 57. Temperaturer i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og i<br />

den side der vender mod den kolde side (loftrummet). Produktnavn: Heraflax.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

-10<br />

Lejlighed A 1.3, HBC-Hør, Facade mod V<br />

-15<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod det fri Værelse, V, øvre mod boligen<br />

Stue, nedre mod det fri Stue, nedre mod boligen<br />

Stue, øvre mod det fri Stue, øvre mod boligen<br />

Figur 58. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med formstykker af<br />

høruld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side. Produktnavn: Heraflax.<br />

49


50<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.3, HBC-Hør, Facade mod Ø<br />

-10<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 59. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med formstykker af høruld.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side. Produktnavn: Heraflax.<br />

Fugtindhold [masse-%]<br />

15,0<br />

14,5<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed A 1.3, HBC-Hør, Loft<br />

10,0<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 60. Fugtindhold i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ. Produktnavn:<br />

Heraflax.<br />

Fugtindhold [masse-%]<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

10,0<br />

Lejlighed A 1.3, HBC-Hør, Facade mod V<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 61. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ. Produktnavn: Heraflax.


Fugtindhold [masse-%]<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

10,0<br />

Lejlighed A 1.3, HBC-Hør, Facade mod Ø<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 62. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ. Produktnavn: Heraflax.<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.4, HBC-Hør, Loft<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 63. Temperaturer i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet). Produktnavn: Heraflax.<br />

51


52<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.4, HBC-Hør, Facade mod V<br />

-10<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 64. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med formstykker af<br />

høruld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side. Produktnavn: Heraflax.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.4, HBC-Hør, Facade mod Ø<br />

-10<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 65. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med formstykker af høruld.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side. Produktnavn: Heraflax.<br />

Fugtindhold [masse-%]<br />

15,0<br />

14,5<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed A 1.4, HBC-Hør, Loft<br />

10,0<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 66. Fugtindhold i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ. Produktnavn:<br />

Heraflax.


Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

10,0<br />

Lejlighed A 1.4, HBC-Hør, Facade mod V<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 67. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ. Produktnavn: Heraflax.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed A 1.4, HBC-Hør, Facade mod Ø<br />

10,0<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 68. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ. Produktnavn: Heraflax.<br />

53


54<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed A 1.5, Rockw ool, Loft<br />

-5<br />

16.10.01 04.01.02 25.03.02 13.06.02 01.09.02 20.11.02 08.02.03 29.04.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 69. Temperaturer i loftisoleringen over en bolig der er isoleret med batts af stenuld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.5, Rockw ool, Facade mod V<br />

-10<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 70. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med batts af stenuld.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.5, Rockw ool, Facade mod Ø<br />

-10<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 71. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med batts af stenuld.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

10,0<br />

Lejlighed A 1.5, Rockw ool, Loft<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Tid [dd:mm:år]<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 72. Fugtindhold i loftisoleringen over en bolig der er isoleret med batts af stenuld. Fugtindholdet er<br />

målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

20,0<br />

19,0<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

Lejlighed A 1.5, Rockw ool, Facade mod V<br />

12,0<br />

11,0<br />

10,0<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 73. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med batts af stenuld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed A 1.5, Rockw ool, Facade mod Ø<br />

10,0<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 74. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med batts af stenuld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

55


56<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.6, Rockw ool, Loft<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 75. Temperaturer i loftisoleringen over en bolig der er isoleret med batts af stenuld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

-10<br />

Lejlighed A 1.6, Rockw ool, Facade mod V<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 76. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med batts af stenuld.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed A 1.6, Rockw ool, Facade mod Ø<br />

-10<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 77. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med batts af stenuld.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

10,0<br />

Lejlighed A 1.6, Rockw ool, Loft<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Tid [dd:mm:år]<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 78. Fugtindhold i loftisoleringen over en bolig der er isoleret med batts af stenuld. Fugtindholdet er<br />

målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

20,0<br />

19,0<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

Lejlighed A 1.6, Rockw ool, Facade mod V<br />

12,0<br />

11,0<br />

10,0<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 79. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med batts af stenuld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed A 1.6, Rockw ool, Facade mod Ø<br />

10,0<br />

16.10.01 4.1.02 25.3.02 13.6.02 1.9.02 20.11.02 8.2.03 29.4.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 80. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med batts af stenuld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

57


58<br />

Temperatur [oC]<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.1, Isodan, Loft<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 81. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed B 1.1, Isodan, Facade mod V<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 82. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed B 1.1, Isodan, Facade mod Ø<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 83. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

16,00<br />

15,00<br />

14,00<br />

13,00<br />

12,00<br />

11,00<br />

Lejlighed B 1.1, Isodan, Loft<br />

10,00<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Loft over bad mod det fri<br />

Tid [dd:mm:år]<br />

Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 84. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.1, Isodan, Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 85. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,00<br />

15,00<br />

14,00<br />

13,00<br />

12,00<br />

11,00<br />

Lejlighed B 1.1, Isodan, Facade mod Ø<br />

10,00<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 86. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

59


60<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.2, Isodan, Loft<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 87. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed B 1.2, Isodan, Facade mod V<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 88. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed B 1.2, Isodan, Facade mod Ø<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 89. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

10,0<br />

Lejlighed B 1.2, Isodan, Loft<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 90. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.2, Isodan, Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 91. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.2, Isodan, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 92. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

61


62<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed B 1.3, LRC-Hør, Loft<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 93. Temperaturer i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.3, LRC-Hør, Facade mod V<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Loft over køkken mod boligen<br />

Figur 94. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med formstykker af<br />

høruld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.3, LRC-Hør, Facade mod Ø<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 95. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med formstykker af høruld.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed B 1.3, LRC-Hør, Loft<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 96. Fugtindhold i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

18,0<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.3, LRC-Hør, Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 97. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.3, LRC-Hør, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 98. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

63


64<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed B 1.4, LRC-Hør, Loft<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 99. Temperaturer i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.4, LRC-Hør, Facade mod V<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 100. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med formstykker af<br />

høruld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.4, LRC-Hør, Facade mod Ø<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 101. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med formstykker af<br />

høruld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.


Fugtindhold [masse-%]<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed B 1.4, LRC-Hør, Loft<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 102. Fugtindhold i loftisoleringen over en bolig der er isoleret med formstykker af høruld. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.4, LRC-Hør, Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 103. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.4, LRC-Hør, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 104. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med formstykker af høruld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

65


66<br />

Temperatur [oC]<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed B 1.5, Isover, Loft<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 105. Temperaturer i loftisoleringen over en bolig der er isoleret med formstykker af glasuld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

den side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.5, Isover, Facade mod V<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 106. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med formstykker af<br />

glasuld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed B 1.5, Isover, Facade mod Ø<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 107. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med formstykker af<br />

glasuld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.


Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

10,0<br />

Lejlighed B 1.5, Isover, Loft<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02<br />

Tid [dd:mm:år]<br />

9.1.03 30.3.03<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 108. Fugtindhold i loftisoleringen over en bolig der er isoleret med formstykker af glasuld. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

19,0<br />

18,0<br />

17,0<br />

Lejlighed B 1.5, Isover, Facade mod V<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 109. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med formstykker af<br />

glasuld. Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.5, Isover, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 110. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med formstykker af glasuld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

67


68<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

Lejlighed B 1.6, Isover, Loft<br />

0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 111. Temperaturer i loftisoleringen over en bolig der er isoleret med formstykker af glasuld. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

den side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

-10<br />

Lejlighed B 1.6, Isover, Facade mod V<br />

-15<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 112. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med formstykker af<br />

glasuld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

Lejlighed B 1.6, Isover, Facade mod Ø<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 113. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med formstykker af<br />

glasuld. Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.


Fugtindhold [masse-%]<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed B 1.6, Isover, Loft<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 114. Fugtindhold i loftisoleringen over en bolig der er isoleret med formstykker af glasuld. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

20,0<br />

18,0<br />

16,0<br />

14,0<br />

12,0<br />

Lejlighed B 1.6, Isover, Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 115. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med formstykker af<br />

glasuld. Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed B 1.6, Isover, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 116. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med formstykker af glasuld.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

69


70<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.1, Ekofiber (Vind), Loft<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 117. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.1, Ekofiber (Vind), Facade mod V<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 118. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed C 1.1, Ekofiber (Vind), Facade mod Ø<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 119. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

13,50<br />

13,00<br />

12,50<br />

12,00<br />

11,50<br />

11,00<br />

10,50<br />

Lejlighed C 1.1, Ekofiber (Vind), Loft<br />

10,00<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Loft over bad mod det fri<br />

Tid [dd:mm:år]<br />

Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 120. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed C 1.1, Ekofiber (Vind), Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 121. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

15,00<br />

14,50<br />

14,00<br />

13,50<br />

13,00<br />

12,50<br />

12,00<br />

Lejlighed C 1.1, Ekofiber (Vind), Facade mod Ø<br />

11,50<br />

11,00<br />

10,50<br />

10,00<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 122. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

71


72<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.2, Ekofiber (Vind), Loft<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 123. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.2, Ekofiber (Vind), Facade mod V<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 124. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.2, Ekofiber (Vind), Facade mod Ø<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 125. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed C 1.2, Ekofiber (Vind), Loft<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 126. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

15,0<br />

14,5<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

10,0<br />

Lejlighed C 1.2, Ekofiber (Vind), Facade mod V<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 127. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

15,0<br />

14,5<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

10,0<br />

Lejlighed C 1.2, Ekofiber (Vind), Facade mod Ø<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 128. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

73


74<br />

Temperatur [oC]<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

-10<br />

Lejlighed C 1.3, Papiruld, Loft<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 129. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.3, Papiruld, Facade mod V<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 130. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed C 1.3, Papiruld, Facade mod Ø<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 131. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed C 1.3, Papiruld, Loft<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 132. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed C 1.3, Papiruld, Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 133. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

17,0<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed C 1.3, Papiruld, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 134. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

75


76<br />

Temperatur [oC]<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.4, Papiruld, Loft<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 135. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den<br />

side der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.4, Papiruld, Facade mod V<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 136. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod<br />

boligen, og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed C 1.4, Papiruld, Facade mod Ø<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 137. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed C 1.4, Papiruld, Loft<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Loft over bad mod det fri<br />

Tid [dd:mm:år]<br />

Loft over bad mod boligen<br />

Loft over køkken mod det fri Loft over køkken mod boligen<br />

Figur 138. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af cellulose. Fugtindholdet<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

15,0<br />

14,5<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

10,0<br />

Lejlighed C 1.4, Papiruld, Facade mod V<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 139. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed C 1.4, Papiruld, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Køkken, nedre mod det fri<br />

Køkken, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Køkken, nedre mod boligen<br />

Køkken, øvre mod boligen<br />

Figur 140. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af cellulose.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

77


78<br />

Temperatur [oC]<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.5, Perlite, Loft<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 141. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af perlit. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.5, Perlite, Facade mod V<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 142. Temperaturer i isoleringen, i facaden mod vest, i en bolig der er isoleret med løsfyld af perlit.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

-5<br />

Lejlighed C 1.5, Perlite, Facade mod Ø<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 143. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af perlit.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.


Fugtindhold [masse-%]<br />

15,00<br />

14,50<br />

14,00<br />

13,50<br />

13,00<br />

12,50<br />

12,00<br />

11,50<br />

11,00<br />

10,50<br />

Lejlighed C 1.5, Perlite, Loft<br />

10,00<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Loft over bad mod det fri<br />

Loft over køkken mod det fri<br />

Tid [dd:mm:år]<br />

Loft over bad mod boligen<br />

Loft over køkken mod boligen<br />

Figur 144. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af perlit. Fugtindholdet er<br />

målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

14,5<br />

14,0<br />

13,5<br />

13,0<br />

12,5<br />

12,0<br />

11,5<br />

11,0<br />

10,5<br />

Lejlighed C 1.5, Perlite, Facade mod V<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Værelse, V, nedre mod det fri<br />

Værelse, V, øvre mod det fri<br />

Stue, nedre mod det fri<br />

Stue, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Værelse, V, nedre mod boligen<br />

Værelse, V, øvre mod boligen<br />

Stue, nedre mod boligen<br />

Stue, øvre mod boligen<br />

Figur 145. Fugtindhold i isoleringen, i facade mod vest, i en bolig der er isoleret med løsfyld af perlit.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og<br />

i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

Fugtindhold [masse-%]<br />

19,00<br />

18,00<br />

17,00<br />

16,00<br />

15,00<br />

14,00<br />

13,00<br />

12,00<br />

11,00<br />

10,00<br />

Lejlighed C 1.5, Perlite, Facade mod Ø<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Værelse, Ø, nedre mod det fri<br />

Værelse, Ø, øvre mod det fri<br />

Tid [dd:mm:år]<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Værelse, Ø, nedre mod boligen<br />

Værelse, Ø, øvre mod boligen<br />

Figur 146. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af perlit.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

79


80<br />

Temperatur [oC]<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.6, Perlite, Loft<br />

-5<br />

-10<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Figur 147. Temperaturer i loftisoleringen over en bolig der er isoleret med løsfyld af perlit. Temperaturerne<br />

er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen, og den side<br />

der vender mod den kolde side (loftrummet).<br />

Temperatur [oC]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Lejlighed C 1.6, Perlite, Facade mod Ø<br />

-5<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri Bad, nedre mod boligen<br />

Bad, øvre mod det fri Bad, øvre mod boligen<br />

Figur 148. Temperaturer i isoleringen, i facaden mod øst, i en bolig der er isoleret med løsfyld af perlit.<br />

Temperaturerne er målt to gange i døgnet i isoleringen i henholdsvis den side som vender mod boligen,<br />

og i den kolde side.<br />

Fugtindhold [masse-%]<br />

16,0<br />

15,0<br />

14,0<br />

13,0<br />

12,0<br />

11,0<br />

Lejlighed C 1.6, Perlite, Loft<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Loft over bad mod det fri Loft over bad mod boligen<br />

Figur 149. Fugtindhold i loftisoleringen over en bolig der er isoleret med løsfyld af perlit. Fugtindholdet er<br />

målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen, og den side der<br />

vender mod den kolde side (loftrummet). Fugtindholdet er angivet som vægtpct. fugt i træ.


Fugtindhold [masse-%]<br />

22,0<br />

20,0<br />

18,0<br />

16,0<br />

14,0<br />

12,0<br />

Lejlighed C 1.6, Perlite, Facade mod Ø<br />

10,0<br />

16.9.01 5.12.01 23.2.02 14.5.02 2.8.02 21.10.02 9.1.03 30.3.03<br />

Tid [dd:mm:år]<br />

Bad, nedre mod det fri<br />

Bad, øvre mod det fri<br />

Bad, nedre mod boligen<br />

Bad, øvre mod boligen<br />

Figur 150. Fugtindhold i isoleringen, i facade mod øst, i en bolig der er isoleret med løsfyld af perlit.<br />

Fugtindholdet er målt to gange i døgnet i isoleringen i henholdsvis den side, som vender mod boligen,<br />

og i den kolde side. Fugtindholdet er angivet som vægtpct. fugt i træ.<br />

81


82<br />

Bilag B Temperatur og relativ luftfugtighed i<br />

lejligheder<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 0.1, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02 08-02-03 09-04-03<br />

Stue, T Bad, TDato Stue, RF Bad, RF<br />

Figur 151. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen og <strong>på</strong> badeværelset. Lejligheden er beliggende i<br />

underetagen, i den del af byggeriet som er i to etager.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 0.2, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Sovevær., T Bad, T<br />

Stue, RF Sovevær., RF Bad, RF<br />

Figur 152. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset. Lejligheden<br />

er beliggende i underetagen, i den del af byggeriet som er i to etager.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]


T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 1.1, Thermocell<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Kontor, T<br />

Kontor, RF<br />

Bad, T<br />

Bad, RF<br />

Figur 153. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af træfiber. <strong>Måling</strong>erne er foretaget i stuen, i rummet anvendt til kontor og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 1.2, Thermocell<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 154. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af træfiber. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 1.3, HBC-hør<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Sovevær., T Bad, T<br />

Stue, RF Sovevær., RF Bad, RF<br />

Figur 155. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af høruld. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]<br />

RF [%]<br />

83


84<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 1.4, HBC-hør<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 156. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af høruld. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 1.5, Rockw ool<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 157. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

batts af stenuld. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed A 1.6, Rockw ool<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Kontor, T Bad, T<br />

Stue, RF Kontor, RF Bad, RF<br />

Figur 158. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

batts af stenuld. <strong>Måling</strong>erne er foretaget i stuen, i rummet anvendt til kontor og <strong>på</strong> badeværelset.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]<br />

RF [%]


T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 0.1, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Bad, T Stue, RF Bad, RF<br />

Figur 159. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen og <strong>på</strong> badeværelset. Lejligheden er beliggende i<br />

underetagen i den del af byggeriet som er i to etager.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 0.2, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Bad, T Stue, RF Bad, RF<br />

Figur 160. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen og <strong>på</strong> badeværelset. Lejligheden er beliggende i<br />

underetagen i den del af byggeriet som er i to etager.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.1, Isodan<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 161. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af cellulose. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]<br />

RF [%]<br />

85


86<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.2, Isodan<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 162. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af cellulose. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.3, LRC-hør<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 163. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af høruld. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.4, LRC-hør<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 164. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af høruld. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]<br />

RF [%]


T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.5, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Sovevær., T Bad, T<br />

Stue, RF Sovevær., RF Bad, RF<br />

Figur 165. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed B 1.6, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Kontor, T Bad, T<br />

Stue, RF Kontor, RF Bad, RF<br />

Figur 166. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen, i rummet anvendt til kontor og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 0.1, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Bad, T Stue, RF Bad, RF<br />

Figur 167. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen og i soveværelset. Lejligheden er beliggende i<br />

underetagen i den del af byggeriet som er i to etager.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]<br />

RF [%]<br />

87


88<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 0.2, Isover<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Bad, T Stue, RF Bad, RF<br />

Figur 168. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

formstykker af glasuld. <strong>Måling</strong>erne er foretaget i stuen og <strong>på</strong> badeværelset. Lejligheden er beliggende i<br />

underetagen i den del af byggeriet som er i to etager.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 1.1, Ekofiber<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Kontor, T<br />

Kontor, RF<br />

Bad, T<br />

Bad, RF<br />

Figur 169. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af cellulose. <strong>Måling</strong>erne er foretaget i stuen, i rummet anvendt til kontor og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 1.2, Ekofiber<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 170. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af cellulose. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]<br />

RF [%]


T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 1.3, Papiruld<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 171. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af cellulose. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 1.4, Papiruld<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 172. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af cellulose. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 1.5, Perlite<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T Kontor, T Bad, T<br />

Stue, RF Kontor, RF Bad, RF<br />

Figur 173. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af perlit. <strong>Måling</strong>erne er foretaget i stuen, i rummet anvendt til kontor og <strong>på</strong> badeværelset.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

RF [%]<br />

RF [%]<br />

89


90<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lejlighed C 1.6, Perlite<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Stue, T<br />

Stue, RF<br />

Sovevær., T<br />

Sovevær., RF<br />

Bad, T<br />

Bad, RF<br />

Figur 174. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for en bolig isoleret med<br />

løsfyld af perlit. <strong>Måling</strong>erne er foretaget i stuen, i soveværelset og <strong>på</strong> badeværelset.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]


Bilag C Temperatur og relativ luftfugtighed<br />

udendørs og i teknikrum<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Ude foran Teknikrum<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

v.TekA, T v.TekB, T v.TekC T<br />

Figur 175. Temperatur i °C angivet hver anden time udenfor de uisolerede teknikrum i henholdsvis blok<br />

A, B og C.<br />

T [°C]<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Teknikrum<br />

-10<br />

13-06-02 12-08-02 11-10-02 10-12-02<br />

Dato<br />

08-02-03 09-04-03<br />

Teknik A, T Teknik B, T Teknik C, T<br />

Teknik A, RF Teknik B, RF Teknik C, RF<br />

Figur 176. Temperatur i °C og relativ luftfugtighed i % angivet hver anden time for de uisolerede teknikrum<br />

i henholdsvis blok A, B og C. I vinterperioden er den relative luftfugtighed i teknikrummet i blok A<br />

højere end i teknikrummene i blok B og C, årsagen til dette var oversvømmelse i teknikrummet i blok A.<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

RF [%]<br />

91


Borup Seniorby er et demonstrationsbyggeri hvori der<br />

både er anvendt <strong>alternative</strong> <strong>isoleringsmaterialer</strong> og mineraluld.<br />

Denne rapport viser fugtophobningen i de valgte<br />

isoleringsprodukter, og redegør for hvorvidt isoleringsarbejder<br />

er udført korrekt. Ni forskellige produkter enten i<br />

form af løsfyld eller formstykker indgår i undersøgelsen.<br />

Der redegøres for fugtophobningen i løbet af to vintre, om<br />

isoleringsmaterialet udfylder de hulrum, der var tiltænkt<br />

isoleret, og om de enkelte <strong>isoleringsmaterialer</strong> egner sig<br />

bedre til nogle typer opgaver end andre.<br />

1. udgave, 2004<br />

ISBN 87-563-1204-0<br />

ISSN 1600-8022