with an external hydrophobic bacteria fi lter<br />
integrated into the system. Basically, the<br />
ASSKEA M – <strong>Series</strong> units are divided into the<br />
following groups according to their various<br />
fi ttings:<br />
Analogue (M20, M30) (Fig. 4)<br />
On the stationary, or inpatient suction devices,<br />
the vacuum control is on the secondary<br />
air principle <strong>and</strong> this is also the case for the<br />
analogue, mobile versions (for outpatient or<br />
ambulance use). Both recharging <strong>and</strong> operation<br />
take place using the 12V mains adaptor<br />
supplied.<br />
Digital (M20D, M30D) (Fig. 5)<br />
The digital mobile versions have a touch fi lm<br />
to use for setting the vacuum desired <strong>and</strong> to<br />
control the vacuum by means of an electronic<br />
sensor. Both recharging <strong>and</strong> operation<br />
take place using the 12V mains adaptor supplied.<br />
Digital unit with wall-holder (M20W, M30W)<br />
(Fig. 5)<br />
The digital mobile suction units which have<br />
a wall-holder can also be charged or operated<br />
via the contacts integrated into the wallholder<br />
or via the mains adaptor. The vacuum<br />
level is controlled digitally by means of an<br />
electronic sensor.<br />
Fig. 4<br />
Fig. 5<br />
up<br />
down<br />
on/off<br />
max<br />
2.3.3 Notes on the dual fi lter system<br />
CAUTION!<br />
Risk to health from dealing<br />
with infectious or pathogenic<br />
organisms.<br />
Any germs <strong>and</strong> pathogens<br />
in the secretions will cause<br />
damage to health.<br />
• Never operate the unit without<br />
its external bacterial fi lter. (Exception:<br />
the “One Way” unit)<br />
• At least one spare external<br />
fi lter must be kept on h<strong>and</strong><br />
at all times.<br />
The ASSKEA dual fi lter system consists of an<br />
external fi lter <strong>and</strong> a fi lter integrated into the<br />
unit itself. Both of these fi lters are hydrophobic<br />
bacteria fi lters (hydrophobic means that<br />
they reject liquid) <strong>and</strong> they are 99.999% effective<br />
against bacteria <strong>and</strong> viruses.<br />
The internal bacteria fi lter is used for all AS-<br />
SKEA units of the S <strong>and</strong> M-<strong>Series</strong>.<br />
The external fi lter is only necessary in tank<br />
systems which do not use a hydrophobic fi lter<br />
as overfl ow control. It is there to prevent<br />
over-suction if mechanical overfl ow control<br />
mechanisms should fail.<br />