7 Technical data/ continuation<br />

<strong>ZWR2MSKU</strong><br />

Environmental conditions: as per ETS 300 019<br />

Operation Air temperature: -25°C … +55°C<br />

Relative air humidity: 5% … 95%<br />

Storage Air temperature: -25°C … +55°C<br />

Relative air humidity: 10% … 100%<br />

Transport Air temperature: -25°C … +70°C<br />

Relative air humidity: 60% … 95%<br />

Standards:<br />

Safety EN 60 950-1<br />

Electromagnetic compatibility EN 55022, class B; ITU-T K.21;<br />

ETSI EN 300 386; ETSI ES 201 468<br />

8 Remarks<br />

Keep this Operating Manual available! Before putting the device into operation, please make<br />

yourself familiar with the safety precautions (→ Chapter 9).<br />

We reserve the right to apply technical modifications aimed to further improvement of the<br />

product performance.<br />

9 Safety precautions<br />

For your own safety, the following hints shall be observed. Please read them carefully, before<br />

you put the device into operation.<br />

Precautions against electrostatic discharge<br />

Upon opening and installation of components of the SHDSL transmission system, attention<br />

shall be paid to the safety precautions as stipulated by DIN 100 015.<br />

Safety precautions during thunderstorms<br />

Keep away from manipulations on the SHDSL transmission system and its components<br />

during thunderstorms (Do not disconnect or connect sub-units or cables).<br />

Grounding and potential equalization<br />

During installation, operation and maintenance of the SHDSL transmission system, the<br />

regulations as set out in DIN VDE 0800, part 2, shall be observed.<br />

Warning of dangerous electric voltage<br />

The SHDSL transmission system has interfaces being under dangerous electric voltage.<br />

Therefore, all works on the system should be performed by personnel who has the required<br />

special knowledge.<br />

© ELCON <strong>Systemtechnik</strong> GmbH 2009 Version: 2009/09/09<br />

<strong>ZWR2MSKU</strong> <strong>2P</strong> <strong>EFM</strong><br />

Zwischenregenerator für<br />

SHDSL-Übertragungssysteme<br />

Regenerative repeater for<br />

SHDSL transmission systems<br />

Bedienungsanleitung<br />

User manual<br />

Art.-Nr. 102719


Deutsch: Seite 1<br />

English: Page 14<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

Version: 2009/09/09 Version: 2009/09/09<br />

6 Display elements/ continuation<br />

7 Technical data<br />

DSL1 DSL2 EIN<br />

ELCON 07 0001 G__ Ä__<br />

<strong>ZWR2MSKU</strong> 900171<br />

Figure 9: View of the front panel with LED display<br />

DSL interface:as per ETSI TS 101 524 resp. ITU-T G.991.2<br />

Bit rate 192 kbps … 3840 kbps / 5696 kbps<br />

Line digit rate up to 1282 2 / 3 kbaud / 1426 kbaud<br />

Line code TC-16-PAM / TC-32-PAM<br />

Impedance 135 Ω<br />

Degree of protection TNV3<br />

Power supply:<br />

Input voltage range of the local power supply -40.5 V to -75 V �<br />

Power consumption 1-DA mode < 3 W / < 2.2 W (local / remote powered)<br />

2×1-DA mode < 4.8 W / < 3.8 W (local / remote powered)<br />

Casing:<br />

Version Metal casing with integrated display elements<br />

and physical interfaces<br />

Display elements 3 LEDs for status indication<br />

Casing dimensions 109.4 × 194 × 67.5 mm 3 (W × D × H)<br />

Weight ca. 1.35 kg<br />

S__<br />

25


6 Display elements<br />

The <strong>ZWR2MSKU</strong> front panel offers 3 light-emitting diodes to signal the different operating<br />

states. Their meaning is determined in below table:<br />

LED Colour State Meaning<br />

ON green ON Local or remote power supply is applied to the<br />

<strong>ZWR2MSKU</strong>; Internal self test showed no faults<br />

blinking at<br />

1 Hz<br />

device is being initialized<br />

blinking at Int-B-alarm set (Device PCB temperature exceeds 80°C) or<br />

4 Hz internal error (e.g. SDFE-load)<br />

dimmed<br />

blinking at<br />

1 Hz<br />

EOC-reset command or Annex Autonegotiation enabled<br />

OFF No supply voltage<br />

ON SHDSL path is not connected, BER > 10 -3 DSL1 /<br />

DSL2 **<br />

red<br />

, LOS<br />

blinking at<br />

4 Hz<br />

SHDSL line (DSL LTU-side) is being activated<br />

blinking at Waiting time between end of activation procedure at LTU<br />

2 Hz side and start of activation at NTU side<br />

blinking at SHDSL line (DSL NTU-side) is being activated or device<br />

1 Hz is being initialized<br />

flashes short- SHDSL section before <strong>ZWR2MSKU</strong> is being activated<br />

ly every (RSP signalling)<br />

second * (Standard mode: section between ZWR and NTU;<br />

<strong>EFM</strong>-mode: section between ZWR and LTU)<br />

flashes shortly<br />

every 5 s<br />

SRU-C loop or diagnostic mode enabled<br />

goes out Line Probing Session enabled<br />

shortly every (Standard mode: section between ZWR and NTU;<br />

second <strong>EFM</strong>-mode: section between ZWR and LTU)<br />

goes out<br />

shortly every<br />

5 s<br />

Line active, but EBER alarm<br />

dimmed<br />

blinking at<br />

1 Hz<br />

EOC-reset command or Annex Autonegotiation enabled<br />

OFF Faultless data transmission<br />

* Signalling may occur also then if there is no physical link to the LTU<br />

** the LED DSL2 is only active in 2×1DA mode<br />

Table 2: Meaning of the LED displays<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

Version: 2009/09/09 Version: 2009/09/09<br />

24 1<br />

Inhalt<br />

1. Kurzbeschreibung <strong>ZWR2MSKU</strong> 2<br />

2. Steckerbelegung 5<br />

3. Blockschaltbild <strong>ZWR2MSKU</strong> 8<br />

4. Bedienelemente 9<br />

5. Montage des <strong>ZWR2MSKU</strong> in den Baugruppenträger 10<br />

6. Anzeigeelemente 11<br />

7. Technische Daten 12<br />

8. Hinweise 13<br />

9. Sicherheitshinweise 13


1 Kurzbeschreibung <strong>ZWR2MSKU</strong><br />

Der <strong>ZWR2MSKU</strong> dient z.B. der Reichweitenerhöhung von digitalen Übertragungssystemen<br />

und kommt zum Einsatz, wenn die Leitungslänge zwischen dem Leitungsendgerät LTU und<br />

dem Netzabschlussgerät NTU die maximale Reichweite der DSL-Schnittstelle überschreitet.<br />

Mit einem <strong>ZWR2MSKU</strong> erzielt man eine Verdoppelung, mit zwei kaskadierten<br />

<strong>ZWR2MSKU</strong> eine Verdreifachung der Übertragungsreichweite eines SHDSL-Systems.<br />

Der Zwischenregenerator <strong>ZWR2MSKU</strong> ist mit vier Kupferschnittstellen (DSL-<br />

Schnittstellen) ausgeführt und regeneriert das gedämpfte, verzerrte Signal der ankommenden<br />

Impulsfolgen und leitet es dann weiter.<br />

Auf der DSL-Schnittstelle wird zur Datenübertragung ein TC-16-PAM- bzw. TC-32-PAMcodiertes<br />

Sendesignal verwendet. Die Übertragung erfolgt bidirektional über ein oder zwei<br />

Doppeladern (1-DA- oder 2×1-DA-System). Das anliegende Digitalsignal wird dabei transparent<br />

auf der SHDSL-Strecke durchgereicht. Die Sende- und Empfangsschaltung der Leitungsschnittstellen<br />

ist mit entsprechenden SHDSL-Transceivern mit Echokompensation<br />

realisiert. Die Übertragungsrate je Kupferdoppelader beträgt bis zu 3840 kBit/s (mit Leitungscode<br />

TC-16-PAM) bzw. bis zu 5696 kBit/s (mit Leitungscode TC-32-PAM). Anpassungen<br />

der Bitrate werden gemäß LTU-Konfiguration unterstützt. Die Betriebsart (1 DA /<br />

2×1 DA) wird mit einem Schalter eingestellt. Dieser befindet sich im Inneren des Gerätes<br />

und ist nach Entfernen des Gehäusebodens zugänglich.<br />

Das Übertragungssystem ist gemäß den Ausführungen der von ETSI herausgegebenen Technical<br />

Specification TS 101 524 bzw. ITU-T G.991.2 realisiert.<br />

Per SDSL-Overhead (EOC-Kanal) können verschiedene Einstellungen des <strong>ZWR2MSKU</strong><br />

vom LTU aus konfiguriert und Informationen (z.B. Performancedaten oder Temperatur)<br />

abgefragt werden. Auf diesem Weg ist optional auch ein Softwaredownload möglich.<br />

Die Versorgungsspannung des <strong>ZWR2MSKU</strong> wird aus der DSL-seitigen Fernspeisung abgeleitet,<br />

diese wird am LTU bzw. am NTU vom Fernspeisemodul RPS8 bereitgestellt. Weiterhin<br />

besteht die Möglichkeit, den <strong>ZWR2MSKU</strong> mit einer lokalen Speisespannung (z.B. mittels<br />

Speisemodul SPM) zu versorgen, wobei dann die Fernspeisung nicht mehr genutzt wird.<br />

Die Regenerator-Gehäuse sind als Metallkassetten für die Verwendung in einer ZWR-<br />

Aufnahme / in einem ZWR-Baugruppenträger BGT bzw. in einem Zwischenregeneratoreinsatz<br />

ZWRE für den Kvz oder in einer Muffe ausgeführt. Es werden für einen <strong>ZWR2MSKU</strong><br />

zwei Steckplätze benötigt.<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

5 Assembly of <strong>ZWR2MSKU</strong> into the subrack<br />

For inserting the <strong>ZWR2MSKU</strong> into its slot, please use either both upper, the two central, or<br />

both lower guide rails. This permits to assemble up to three <strong>ZWR2MSKU</strong> per ZWR holder.<br />

When plugging the <strong>ZWR2MSKU</strong> into the ZWR holder, make sure that the LEDs on front<br />

panel are on topside. The two pilots on the housing back side are used as reverse polarity<br />

protection. The metal bracket on the front of the repeater can be used for removing the unit<br />

from the slot.<br />

Commissioning<br />

After inserting the <strong>ZWR2MSKU</strong> into the corresponding slot, the device can be put into<br />

operation. Prerequisite for starting up the <strong>ZWR2MSKU</strong> is the applied local supply voltage or<br />

an activated RPS8 which has been plugged beside the LTU / NTU. The applied voltage is<br />

indicated through the green shining LED „ON“. Further, putting the device into operation<br />

additionally requires activation of the SHDSL transmission path from the LT and NT.<br />

1. The device is beginning with an self-test procedure in the first ca. 5 seconds. During<br />

this time all LEDs are blinking (Note: the LED DSL2 is only active in 2×1DA<br />

mode).<br />

2. After this the LTU is starting up the SHDSL line to the <strong>ZWR2MSKU</strong> (first transmission<br />

path section) and the red LED „DSL“ for the corresponding SHDSL link<br />

is blinking with a frequency of 4 Hz.<br />

3. After successful set-up of the first transmission path section, the red LED „DSL“<br />

for the corresponding SHDSL link is blinking with 1 Hz frequency. During this<br />

time the second transmission path section between the <strong>ZWR2MSKU</strong> and the NTU<br />

/ the second <strong>ZWR2MSKU</strong> will be built-up.<br />

4. As for the <strong>ZWR2MSKU</strong>, the two ends of the transmission line have been set up<br />

when the red LED „DSL“ goes out.<br />

The <strong>ZWR2MSKU</strong> is controlled by the LTU and can be managed by the Network Management<br />

System (NMS).<br />

Special characteristic during the SHDSL Start-up<br />

Please take into account, that the restart time of an aborted SHDSL line could reach up to<br />

2 minutes by using one <strong>ZWR2MSKU</strong> and up to 4 minutes by using two repeaters in the<br />

SHDSL transmission path (the given time targets are defined by the ITU-/ ETSI standards<br />

ITU-T G.991.2 and ETSI TS 101 524).<br />

To ensure that the line is set up successfully, both twin wires have to be connected correctly.<br />

Version: 2009/09/09 Version: 2009/09/09<br />

2 23


4 Operating elements<br />

The switches on the circuit board allow to execute a configuration of the <strong>ZWR2MSKU</strong>.<br />

These switches are placed inside the device and become accessible after removing the casing<br />

bottom plate. For this, release the six screws on the casing bottom. The location of the<br />

switches and their position in default state can be seen in figure 8. The switches shall be<br />

operated by means of a suitable screwdriver (blade width approx. 3 mm). When changing the<br />

switch position, make sure to not damage the PCB lying beneath.<br />

With help of the „MODE“ switch you can select the mode of operation: 1-pair mode (1-DA)<br />

or dual 1-pair mode (2×1-DA) (related markings on the circuit board: „1P“ and „<strong>2P</strong>“).<br />

The switches „RPS CONFIG“ allow to determine for each SHDSL separately („RPS1“ /<br />

„RPS2“), whether the remote power supply shall be transmitted to the next <strong>ZWR2MSKU</strong> /<br />

to the next NTU (marking: „ “) or whether this shall not be executed (marking: „ “).<br />

After setting the switches, the casing bottom plate need to be fixed again by fastening the six<br />

screws.<br />

Figure 8: Switch for setting the operating mode and remote power supply<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

1 Kurzbeschreibung <strong>ZWR2MSKU</strong>/ Fortsetzung<br />

Speisekonzept<br />

Der <strong>ZWR2MSKU</strong> kann mit lokaler Speisung oder mit Fernspeisung (LTU-seitig oder NTUseitig)<br />

betrieben werden. Liegt eine lokale Speisespannung an (-40,5 V � ... -75 V �), so<br />

wird diese vom <strong>ZWR2MSKU</strong> verwendet, auch wenn noch zusätzlich eine Fernspeisespannung<br />

anliegt. Die lokale Speisung hat immer den Vorrang. Bei Fernspeisung wird der<br />

<strong>ZWR2MSKU</strong> über beide Doppeladern mit jeweils 112 V � (± 3 V �) vom Leitungsendgerät<br />

/ Netzabschlussgerät aus gespeist. Es ist möglich, die Fernspeisespannung zum nächsten<br />

<strong>ZWR2MSKU</strong> / zum nächsten NTU durchzureichen.<br />

Der prinzipielle Aufbau eines SHDSL-Systems mit einem Regenerator sowie mit zwei<br />

kaskadierten Regeneratoren wird in den nachfolgenden Bildern gezeigt.<br />

Bild 1: Aufbau eines 2×1 DA-SHDSL-Systems mit einem Regenerator<br />

Bild 2: Aufbau zweier 2×1 DA-SHDSL-Systeme mit je zwei kaskadierten Regeneratoren<br />

Version: 2009/09/09 Version: 2009/09/09<br />

22 3<br />

LTU<br />

mit RPS8<br />

LTU<br />

mit RPS8<br />

LTU<br />

mit RPS8<br />

LTU<br />

mit RPS8<br />

LTU<br />

mit RPS8<br />

LTU<br />

mit RPS8<br />

DSL (1-Paar Kupferkabel,<br />

LTU-seitig)<br />

Fernspeisung<br />

über DSL oder<br />

DSL (1-Paar Kupferkabel,<br />

LTU-seitig)<br />

<strong>ZWR2MSKU</strong><br />

<strong>ZWR2MSKU</strong><br />

Nr. 1<br />

Fernspeisung des LTUseitigen<br />

<strong>ZWR2MSKU</strong><br />

Nr. 1 über das LTU<br />

DSL (1-Paar Kupferkabel,<br />

LTU-seitig)<br />

<strong>ZWR2MSKU</strong><br />

Nr. 1<br />

Fernspeisung des LTUseitigen<br />

<strong>ZWR2MSKU</strong><br />

Nr. 1 über das LTU<br />

DSL (1-Paar-Kupferkabel,<br />

NTU-seitig)<br />

lokale Speisung<br />

(SPM - Option)<br />

DSL<br />

(2×1-Paar<br />

Kupferkabel)<br />

DSL<br />

(2×1-Paar<br />

Kupferkabel)<br />

weitergeleitete<br />

Fernspeisung des<br />

LTU-seitigen<br />

<strong>ZWR2MSKU</strong> Nr. 2<br />

vom LTU über<br />

<strong>ZWR2MSKU</strong> Nr. 1<br />

NTU<br />

NTU<br />

<strong>ZWR2MSKU</strong><br />

Nr. 2<br />

DSL (1-Paar Kupferkabel,<br />

NTU-seitig)<br />

Fernspeisung des NTUseitigen<br />

<strong>ZWR2MSKU</strong> Nr. 2<br />

über das NTU (spez. Option)<br />

<strong>ZWR2MSKU</strong><br />

Nr. 2<br />

DSL (1-Paar Kupferkabel,<br />

NTU-seitig)<br />

NTU mit<br />

RPS8<br />

NTU mit<br />

RPS8<br />

NTU mit<br />

RPS8<br />

NTU mit<br />

RPS8


1 Kurzbeschreibung <strong>ZWR2MSKU</strong>/ Fortsetzung<br />

Ansichten<br />

Gehäuse<br />

LED-Anzeige<br />

Bügelgriff<br />

Bild 3: Ansicht der Gehäusefrontseite<br />

Gehäuse<br />

Positionierbolzen<br />

13-pol. Steckverbinder<br />

Bild 4: Ansicht Gehäuserückseite <strong>ZWR2MSKU</strong><br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

3 Block diagram of <strong>ZWR2MSKU</strong><br />

The block diagram of the <strong>ZWR2MSKU</strong> is shown in figure 7. The device consists of the<br />

following function units:<br />

Microprocessor system<br />

consisting of microcontroller, SRAM and a FLASH.<br />

DSL interface connection<br />

consisting of one quad SHDSL transceiver with corresponding I/O circuitry, with hybrid<br />

network, transmitters and protective elements.<br />

UB power supply interface<br />

The interface is short-circuit-proof, so that a reverse polarity would cause no response of the<br />

internal fuse, and no damage to the device / sub-unit. The supply voltage ranges from<br />

-40.5 V to -75 V.<br />

Figure 7: Block diagram of <strong>ZWR2MSKU</strong><br />

Version: 2009/09/09 Version: 2009/09/09<br />

4 21<br />

UB<br />

DSL<br />

DSL<br />

Power pack<br />

DC / DC<br />

EMC<br />

EMC<br />

Line<br />

interface<br />

Line<br />

interface<br />

Remote supply<br />

DC / DC<br />

Quad SHDSL Transceiver<br />

AFE/DSP<br />

AFE/DSP<br />

Controller &<br />

Peripheral<br />

AFE/DSP<br />

AFE/DSP<br />

Line<br />

interface<br />

Line<br />

interface<br />

EMC<br />

EMC<br />

DSL<br />

DSL


2 Interfaces/ continuation<br />

ZWR No. 1<br />

ZWR No. 2<br />

ZWR No. 3<br />

Figure 6: ZWR holder incl. three <strong>ZWR2MSKU</strong> and connector panel<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

2 Steckerbelegung<br />

Steckverbinder-Anschlussbelegung des <strong>ZWR2MSKU</strong><br />

Stiftleiste 1:<br />

2, 3 SHDSL-Anschluss in Richtung LT (1. Pfad)<br />

7 FPE<br />

11, 12 Lokale Speisespannung im Bereich von -40,5 V � ... -75 V �<br />

11: Minuspotential<br />

12: Pluspotential<br />

Stiftleiste 2:<br />

7 FPE<br />

11, 12 SHDSL-Anschluss in Richtung NT (1. Pfad)<br />

Stiftleiste 3:<br />

2, 3 SHDSL-Anschluss in Richtung LT (2. Pfad)<br />

7 FPE<br />

Stiftleiste 4:<br />

7 FPE<br />

11, 12 SHDSL-Anschluss in Richtung NT (2. Pfad)<br />

Version: 2009/09/09 Version: 2009/09/09<br />

20 5<br />

1<br />

2<br />

3<br />

4<br />

2<br />

12<br />

3 7 11<br />

11<br />

2<br />

12<br />

7<br />

3 7<br />

11<br />

7<br />

Bild 5: Anschlussbelegung der Steckverbinder des <strong>ZWR2MSKU</strong><br />

12


2 Steckerbelegung/ Fortsetzung<br />

Belegung des Anschlussfelds der ZWR-Aufnahme<br />

PIN F1 an F1 ab<br />

F2 an<br />

F2 ab<br />

→ DSL zum NT → DSL vom LT → Stromversorgung<br />

1 a/b - DSL1 out (ZWR1) DSL1 in (ZWR1) a = + ; b = - (ZWR1)<br />

2 a/b - DSL2 out (ZWR1) DSL2 in (ZWR1) -<br />

3 a/b - DSL1 out (ZWR2) DSL1 in (ZWR2) a = + ; b = - (ZWR2)<br />

4 a/b - DSL2 out (ZWR2) DSL2 in (ZWR2) -<br />

5 a/b - DSL1 out (ZWR3) DSL1 in (ZWR3) a = + ; b = - (ZWR3)<br />

6 a/b - DSL2 out (ZWR3) DSL2 in (ZWR3) -<br />

Tabelle 1: Belegung des Anschlussfelds der ZWR-Aufnahme<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

2 Interfaces/ continuation<br />

Pin assignment of connector panel of the ZWR holder<br />

PIN F1 an F1 ab<br />

F2 an<br />

F2 ab<br />

→ DSL to NT → DSL from LT → Power supply<br />

1 a/b - DSL1 out (ZWR1) DSL1 in (ZWR1) a = + ; b = - (ZWR1)<br />

2 a/b - DSL2 out (ZWR1) DSL2 in (ZWR1) -<br />

3 a/b - DSL1 out (ZWR2) DSL1 in (ZWR2) a = + ; b = - (ZWR2)<br />

4 a/b - DSL2 out (ZWR2) DSL2 in (ZWR2) -<br />

5 a/b - DSL1 out (ZWR3) DSL1 in (ZWR3) a = + ; b = - (ZWR3)<br />

6 a/b - DSL2 out (ZWR3) DSL2 in (ZWR3) -<br />

Table 1: Pin assignment of connector panel of the ZWR holder<br />

Version: 2009/09/09 Version: 2009/09/09<br />

6 19


2 Interfaces<br />

Pin assignment of the <strong>ZWR2MSKU</strong><br />

Pin connector 1:<br />

2, 3 SHDSL connection in LT direction (1 st path)<br />

7 FPE<br />

11, 12 Local supply voltage ranging from -40.5 V � ... -75 V �<br />

11: Negative potential<br />

12: Positive potential<br />

Pin connector 2:<br />

7 FPE<br />

11, 12 SHDSL connection in NT direction (1 st path)<br />

Pin connector 3:<br />

2, 3 SHDSL connection in LT direction (2 nd path)<br />

7 FPE<br />

Pin connector 4:<br />

7 FPE<br />

11, 12 SHDSL connection in NT direction (2 nd path)<br />

1<br />

2<br />

3<br />

4<br />

2<br />

12<br />

3 7 11<br />

11<br />

2<br />

12<br />

7<br />

3 7<br />

11<br />

7<br />

Figure 5: Connector pin assignment of the <strong>ZWR2MSKU</strong><br />

12<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

2 Steckerbelegung/ Fortsetzung<br />

ZWR Nr. 1<br />

ZWR Nr. 2<br />

ZWR Nr. 3<br />

Bild 6: ZWR-Aufnahme mit drei <strong>ZWR2MSKU</strong> und Anschlussfeld<br />

Version: 2009/09/09 Version: 2009/09/09<br />

18 7


3 Blockschaltbild <strong>ZWR2MSKU</strong><br />

Das Blockschaltbild der <strong>ZWR2MSKU</strong>-Baugruppe ist in Bild 7 gezeigt. Folgende Funktionsblöcke<br />

lassen sich unterscheiden:<br />

Mikroprozessorsystem<br />

bestehend aus Mikrokontroller, SRAM und FLASH.<br />

DSL Schnittstellenanschaltung<br />

bestehend aus einem 4-fach SHDSL-Transceiver mit entsprechender Ein- und Ausgangsbeschaltung<br />

mit Hybridnetzwerk, Übertragern und Schutzelementen.<br />

UB Stromversorgungsschnittstelle<br />

Die Schnittstelle ist kurzschlusssicher und eine Verpolung führt nicht zum Ansprechen der<br />

internen Sicherung bzw. zu einer Zerstörung des Gerätes / der Baugruppe. Der Speisespannungsbereich<br />

liegt im Bereich von -40,5 V bis -75 V.<br />

UB<br />

DSL<br />

DSL<br />

Netzteil<br />

DC / DC<br />

EMV<br />

EMV<br />

Leitungsschnittstelle <br />

Leitungsschnittstelle<br />

Quad SHDSL-Transceiver<br />

AFE/DSP<br />

AFE/DSP<br />

Fernspeisung<br />

DC / DC<br />

Controller &<br />

Peripherie<br />

AFE/DSP<br />

AFE/DSP<br />

Bild 7: Blockschaltbild <strong>ZWR2MSKU</strong><br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

Leitungsschnittstelle <br />

Leitungsschnittstelle<br />

EMV<br />

EMV<br />

DSL<br />

DSL<br />

1 Short description of <strong>ZWR2MSKU</strong>/ continuation<br />

Version: 2009/09/09 Version: 2009/09/09<br />

8 17<br />

Views<br />

Casing<br />

LED display<br />

Metal bracket<br />

Figure 3: View of the casing front side<br />

Pilots<br />

13-pole connectors<br />

Casing<br />

Figure 4: View of casing back side <strong>ZWR2MSKU</strong>


1 Short description of <strong>ZWR2MSKU</strong>/ continuation<br />

Supply concept<br />

The <strong>ZWR2MSKU</strong> can be either locally powered or operated with remote power supply<br />

(LTU-side or NTU-side). If local supply voltage is provided (-40.5 V � ...–75 V �), then<br />

the <strong>ZWR2MSKU</strong> makes use of it even under the condition remote power supply would be<br />

additionally applied. Local feeding always has priority over remote power supply, if both of<br />

them are available. In case of remote power supply, the <strong>ZWR2MSKU</strong> is fed by the line<br />

terminating unit / network terminating unit through both twin wires with each 112 V �<br />

(± 3 V �). It is possible to transmit the remote power supply to the next <strong>ZWR2MSKU</strong> / to<br />

the next NTU.<br />

The figures below show the basic structure of an SHDSL system including one repeater,<br />

respectively, two cascaded repeaters.<br />

LTU<br />

with RPS8<br />

LTU<br />

with RPS8<br />

LTU<br />

with RPS8<br />

LTU<br />

with RPS8<br />

LTU<br />

with RPS8<br />

LTU<br />

with RPS8<br />

DSL (1-pair copper<br />

cable, LTU-side)<br />

Remote power<br />

supply via DSL or<br />

Figure 1: Structure of a 2×1-DA-SHDSL system with one repeater<br />

DSL (1-pair copper<br />

cable, LTU-side)<br />

<strong>ZWR2MSKU</strong><br />

<strong>ZWR2MSKU</strong><br />

No. 1<br />

Remote power supply<br />

of the LTU-side<br />

<strong>ZWR2MSKU</strong> no. 1<br />

via LTU<br />

DSL (1-pair copper<br />

cable, LTU-side)<br />

<strong>ZWR2MSKU</strong><br />

No. 1<br />

Remote power supply<br />

of the LTU-side<br />

<strong>ZWR2MSKU</strong> no. 1<br />

via LTU<br />

DSL (1-pair copper<br />

cable, NTU-side)<br />

local powering<br />

(SPM - option)<br />

DSL<br />

(2×1-pair<br />

copper cable)<br />

DSL<br />

(2×1-pair<br />

copper cable)<br />

Forwarded<br />

remote power supply<br />

of the LTU-side<br />

<strong>ZWR2MSKU</strong> no. 2<br />

from LTU via<br />

<strong>ZWR2MSKU</strong> no. 1<br />

Figure 2: Structure of two 2×1-DA-SHDSL systems with two cascaded repeaters per system<br />

NTU<br />

NTU<br />

<strong>ZWR2MSKU</strong><br />

No. 2<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

DSL (1-pair copper<br />

cable, NTU-side)<br />

Remote power supply<br />

of the NTU-side<br />

<strong>ZWR2MSKU</strong> no. 2<br />

via NTU (special option)<br />

<strong>ZWR2MSKU</strong><br />

No. 2<br />

DSL (1-pair copper<br />

cable, NTU-side)<br />

NTU with<br />

RPS8<br />

NTU with<br />

RPS8<br />

NTU with<br />

RPS8<br />

NTU with<br />

RPS8<br />

4 Bedienelemente<br />

Mit den auf der Leiterplatte befindlichen Umschaltern kann eine Konfiguration des<br />

<strong>ZWR2MSKU</strong> vorgenommen werden. Diese befinden sich im Inneren des Gerätes und sind<br />

nach Entfernen des Gehäusebodens zugänglich. Dazu sind die sechs Schrauben auf der<br />

Gehäuseunterseite zu lösen. Die Position der Schalter sowie deren Stellung zum Zeitpunkt<br />

der Auslieferung können Sie Bild 8 entnehmen. Zur Bedienung der Schaltelemente muss ein<br />

geeigneter Schraubendreher (Klingenbreite ca. 3 mm) benutzt werden. Achten Sie beim<br />

Ändern der Schalterposition darauf, Leiterzüge und Bauelemente der darunter befindlichen<br />

Leiterplatte nicht zu beschädigen.<br />

Der Umschalter „MODE“ dient zum Wechseln der Betriebsart zwischen 1-Paar- (1-DA-)<br />

und Dual-1-Paar- (2×1-DA-)Modus (Kennzeichnungen auf der Leiterplatte: „1P“ und „<strong>2P</strong>“).<br />

Mit den Umschaltern „RPS CONFIG“ wird für jede SHDSL-Strecke („RPS1“ / „RPS2“)<br />

separat festgelegt, ob die Fernspeisung zum nächsten <strong>ZWR2MSKU</strong> / zum nächsten NTU<br />

durchgereicht werden soll (Kennzeichnung: „ “) oder ob die Fernspeisung nicht durchgereicht<br />

werden soll (Kennzeichnung: „ “).<br />

Befestigen Sie nach dem Einstellen der Schalter den Gehäuseboden wieder mit den sechs<br />

Schrauben.<br />

Bild 8: Umschalter für Betriebsart und Fernspeisung<br />

Version: 2009/09/09 Version: 2009/09/09<br />

16 9


5 Montage des <strong>ZWR2MSKU</strong> in den Baugruppenträger<br />

Der <strong>ZWR2MSKU</strong> ist so in die ZWR-Aufnahme zu stecken, dass entweder die beiden oberen,<br />

die beiden mittleren oder die beiden unteren Führungsschienen genutzt werden. Damit<br />

lassen sich maximal drei <strong>ZWR2MSKU</strong> pro ZWR-Aufnahme montieren. Achten Sie beim<br />

Einstecken des <strong>ZWR2MSKU</strong> in die ZWR-Aufnahme darauf, dass sich die LEDs auf der<br />

Frontseite oben befinden. Die beiden Positionierbolzen an der Gehäuserückseite dienen<br />

dabei zum Schutz gegen unbeabsichtigte Verpolung. Mittels des an der Vorderseite des Regenerators<br />

befindlichen Metallbügels kann das Gerät aus dem Einschubfach herausgezogen werden.<br />

Inbetriebnahme<br />

Nachdem der <strong>ZWR2MSKU</strong> in den entsprechenden Einschub gesteckt worden ist, kann das<br />

Gerät in Betrieb genommen werden. Zur Inbetriebnahme des <strong>ZWR2MSKU</strong> muss die lokale<br />

Versorgungsspannung anliegen bzw. am LTU / NTU ein RPS8 montiert und aktiviert sein.<br />

Das Vorhandensein einer Spannung wird durch das Leuchten der grünen LED „ON“ angezeigt.<br />

Eine weitere Voraussetzung für die Inbetriebnahme ist, dass die SHDSL-<br />

Übertragungsstrecke vom LT und NT aktiviert wurde.<br />

1. Das Gerät durchläuft einen Autotest, der etwa 5 Sekunden dauert. Während dieser<br />

Zeit blinken alle LEDs (Hinweis: die DSL2-LED ist nur im 2×1DA-Betrieb aktiv).<br />

2. Anschließend beginnt das LTU mit dem Aufbau der SHDSL-Strecke zum<br />

<strong>ZWR2MSKU</strong> (erster Streckenabschnitt), wobei die rote LED „DSL“ der betreffenden<br />

SHDSL-Übertragungsstrecke mit einer Frequenz von 4 Hz blinkt.<br />

3. Nach erfolgreichem Aufbau des ersten Streckenabschnitts blinkt die rote LED<br />

„DSL“ der betreffenden Übertragungsstrecke mit einer Frequenz von 1 Hz, während<br />

dessen der zweite Streckenabschnitt zwischen dem <strong>ZWR2MSKU</strong> und dem<br />

NTU / dem zweiten <strong>ZWR2MSKU</strong> aufgebaut wird.<br />

4. Für den <strong>ZWR2MSKU</strong> sind beide Seiten der Übertragungsstrecke dann aufgebaut,<br />

wenn die rote LED „DSL“ erlischt.<br />

Der <strong>ZWR2MSKU</strong> wird durch das LTU gesteuert und kann vom Network Management<br />

System (NMS) gemanagt werden.<br />

Besonderheit beim Aufbau der SHDSL-Strecke<br />

Bitte beachten Sie, dass der Neustart einer ausgefallenen SHDSL-Strecke bis zu 2 Minuten –<br />

bei Nutzung eines <strong>ZWR2MSKU</strong> – und bis zu 4 Minuten – bei Nutzung von zwei Regeneratoren<br />

innerhalb der SHDSL-Übertragungsstrecke dauern kann (die zulässigen Zeiten sind in<br />

den ITU-/ ETSI-Standards ITU-T G.991.2 bzw. ETSI TS 101 524 festgelegt).<br />

Damit ein erfolgreicher Streckenaufbau stattfinden kann, müssen jeweils beide Doppeladern<br />

korrekt angeschlossen sein.<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

1 Short description of <strong>ZWR2MSKU</strong><br />

The <strong>ZWR2MSKU</strong> has been developed e.g. to increase the range of digital transmission<br />

systems and is used if the line length between the line terminating unit LTU and the network<br />

terminating unit NTU exceeds the maximum range of the DSL interface.<br />

When using one <strong>ZWR2MSKU</strong> the range is doubled, whereas application of two cascaded<br />

<strong>ZWR2MSKU</strong> allows to triple the transmission range of the SHDSL system.<br />

The regenerative repeater <strong>ZWR2MSKU</strong> is equipped with four copper interfaces (DSL ports)<br />

and regenerates the attenuated and distorted signal of incoming pulse sequences and forwards<br />

it further.<br />

A TC-16-PAM- resp. TC-32-PAM-coded transmit signal is used for data transmission at the<br />

DSL interface. The bidirectional transmission runs over one or two twin wires (1-DA system<br />

or 2×1-DA system). The supplied digital signal is transparently sent via the SHDSL path.<br />

The transmit-receive circuit at the line interfaces is implemented by adequate SHDSL transceivers<br />

using the echo compensation method. The line digit rate on the twin-wire copper line<br />

is up to 3840 kbps (with line code TC-16-PAM) resp. up to 5696 kbps (with line code TC-<br />

32-PAM). Fractional rates are supported according to LTU configuration. The operating<br />

mode (1 DA / 2×1 DA) can be set with help of a switch inside the device that becomes accessible<br />

after removing the casing bottom plate.<br />

The transmission system has been implemented as required by the Technical Specification<br />

ETSI TS 101 524 resp. ITU-T G.991.2.<br />

Individual settings of the <strong>ZWR2MSKU</strong> are configured per SDSL-Overhead (EOC channel)<br />

from the LTU, which also provides the option to poll certain information (e.g. performance<br />

data or temperature). Optionally, the software can be downloaded this way, too.<br />

The supply voltage of the <strong>ZWR2MSKU</strong> is derived from the DSL-side remote power supply<br />

that is provided to the LTU resp. to the NTU by the remote power feeding module RPS8. It<br />

is also possible to feed the <strong>ZWR2MSKU</strong> with a local supply voltage (e.g. by means of the<br />

power feeding module SPM), where in such case the remote power supply is not used any<br />

more.<br />

The repeater casings are designed as metallic cassettes for use in a ZWR holder / in a ZWR<br />

subrack BGT resp. a special repeater compartment ZWRE to be plugged into a cable junction<br />

box or into a sleeve. One <strong>ZWR2MSKU</strong> requires two slots.<br />

Version: 2009/09/09 Version: 2009/09/09<br />

10 15


Contents<br />

1. Short description of <strong>ZWR2MSKU</strong> 15<br />

2. Interfaces 18<br />

3. Block diagram of <strong>ZWR2MSKU</strong> 21<br />

4. Operating elements 22<br />

5. Assembly of <strong>ZWR2MSKU</strong> into the subrack 23<br />

6. Display elements 24<br />

7. Technical data 25<br />

8. Remarks 26<br />

9. Safety precautioms 26<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

6 Anzeigeelemente<br />

An der Gerätefront des <strong>ZWR2MSKU</strong> befinden sich 3 Leuchtdioden, die die verschiedenen<br />

Betriebszustände signalisieren. Die Bedeutung ist in folgender Tabelle definiert:<br />

LED Farbe Zustand Bedeutung<br />

ON grün AN lokale oder Fernspeisung liegt am <strong>ZWR2MSKU</strong> an, interner<br />

Selbsttest wurde fehlerfrei durchlaufen<br />

blinkt mit<br />

1 Hz<br />

Gerät wird initialisiert<br />

blinkt mit Int-B-Alarm aktiv (Gerätetemperatur ≥ 80°C) oder interner<br />

4 Hz Fehler (z.B. SDFE-Load)<br />

blinkt gedimmt<br />

mit<br />

1 Hz<br />

EOC-Reset-Befehl oder Annex Autoneg. aktiv<br />

AUS keine Speisespannung<br />

AN SHDSL-Strecke nicht angeschlossen, BFR > 10 -3 DSL1 /<br />

DSL2 **<br />

rot<br />

, LOS<br />

blinkt mit<br />

4 Hz<br />

SHDSL-Strecke (DSL LTU-seitig) wird aktiviert<br />

blinkt mit Wartezeit zwischen Ende der Aktivierung zur LTU-Seite<br />

2 Hz und Beginn der NTU-seitigen Aktivierung<br />

blinkt mit SHDSL-Strecke (DSL NTU-seitig) wird aktiviert oder<br />

1 Hz Gerät wird initialisiert<br />

blitzt kurz vor dem <strong>ZWR2MSKU</strong> liegender SHDSL-Strecken-<br />

aller 1 s * abschnitt wird aktiviert (RSP-Signalisierung)<br />

(Standard-Mode: Abschnitt zwischen ZWR und NTU;<br />

<strong>EFM</strong>-Mode: Abschnitt zwischen ZWR und LTU)<br />

blitzt kurz<br />

aller 5 s<br />

SRU-C Loop oder Diagnostic Mode aktiv<br />

verlöscht Line Probing Session aktiv<br />

kurz aller 1 s (Standard-Mode: Abschnitt zwischen ZWR und NTU;<br />

<strong>EFM</strong>-Mode: Abschnitt zwischen ZWR und LTU)<br />

verlöscht<br />

kurz aller 5 s<br />

Strecke aktiv, aber Alarm EBER<br />

blinkt gedimmt<br />

mit<br />

1 Hz<br />

EOC-Reset-Befehl oder Annex Autoneg. aktiv<br />

AUS fehlerfreie Datenübertragung<br />

* Signalisierung kann auch auftreten, wenn keine physische Verbindung zum LTU besteht<br />

** die DSL2-LED ist nur im 2×1DA-Betrieb aktiv<br />

Tabelle 2: Bedeutung der LED-Anzeigen<br />

Version: 2009/09/09 Version: 2009/09/09<br />

14 11


6 Anzeigeelemente/ Fortsetzung<br />

7 Technische Daten<br />

DSL1 DSL2 EIN<br />

ELCON 07 0001 G__ Ä__<br />

<strong>ZWR2MSKU</strong> 900171<br />

S__<br />

Bild 9: Frontansicht mit LED-Anzeige<br />

DSL-Schnittstelle: entspr. ETSI TS 101 524 bzw. ITU-T G.991.2<br />

Bitrate 192 kBit/s … 3840 kBit/s / 5696 kBit/s<br />

Schrittgeschwindigkeit bis zu 1282 2 / 3 kBaud / 1426 kBaud<br />

Leitungscode TC-16-PAM / TC-32-PAM<br />

Impedanz 135 Ω<br />

Sicherheitsgrad TNV3<br />

Stromversorgung:<br />

Eingangsspannungsbereich der Lokalspeisung -40,5 V bis -75 V �<br />

Leistungsaufnahme 1-DA-Betrieb < 3 W / < 2,2 W (lokal / ferngespeist)<br />

2×1-DA-Betrieb < 4,8 W / < 3,8 W (lokal / ferngespeist)<br />

Gehäuse:<br />

Ausführungsvariante Metallgehäuse mit integrierten Anzeige-<br />

elementen und physikalischen Schnittstellen<br />

Anzeigeelemente 3 LEDs zur Statusanzeige<br />

Gehäuseabmessungen 109,4 × 194 × 67,5 mm 3 (B × T × H)<br />

Gewicht ca. 1,35 kg<br />

<strong>ZWR2MSKU</strong> <strong>ZWR2MSKU</strong><br />

7 Technische Daten/ Fortsetzung<br />

Umweltbedingungen: entsprechend ETS 300 019<br />

Betrieb Lufttemperatur: -25°C … +55°C<br />

rel. Luftfeuchtigkeit: 5% … 95%<br />

Lagerung Lufttemperatur: -25°C … +55°C<br />

rel. Luftfeuchtigkeit: 10% … 100%<br />

Transport Lufttemperatur: -25°C … +70°C<br />

rel. Luftfeuchtigkeit: 60% … 95%<br />

Normen:<br />

Sicherheit EN 60 950-1<br />

EMV EN 55022, Kl. B; ITU-T K.21;<br />

ETSI EN 300 386; ETSI ES 201 468<br />

8 Hinweise<br />

Diese Anweisung aufbewahren!<br />

Bei Inbetriebnahme des Gerätes sind die Sicherheitshinweise zu beachten (→ Kapitel 9).<br />

Technische Änderungen sind dem technischen Fortschritt geschuldet und dienen der Verbesserung<br />

des Gerätes.<br />

9 Sicherheitshinweise<br />

Folgende Sicherheitshinweise sind zu Ihrer Sicherheit zu befolgen. Lesen Sie diese, bevor<br />

Sie das Gerät in Betrieb nehmen.<br />

ESD-Schutzmaßnahmen<br />

Beim Öffnen und bei Einbau von Komponenten des SHDSL-Übertragungssystems sind die<br />

Schutzmaßnahmen nach DIN 100 015 zu beachten.<br />

Vorsichtsmaßnahmen bei Gewitter<br />

Vermeiden Sie Arbeiten am SHDSL-Übertragungssystem und dessen Komponenten bei<br />

Gewittertätigkeit (Ziehen und Stecken von Baugruppen bzw. Leitungen).<br />

Erde und Potentialausgleich<br />

Bei Installation, Betrieb und Wartung des SHDSL-Übertragungssystems ist die DIN VDE<br />

0800, Teil 2 zu beachten.<br />

Warnung vor gefährlicher elektrischer Spannung<br />

Das SHDSL-Übertragungssystem enthält Schnittstellen mit gefährlicher elektrischer Spannung.<br />

Alle Arbeiten am System sollten von Fachpersonal durchgeführt werden.<br />

Version: 2009/09/09 Version: 2009/09/09<br />

12 13