6 SUN PLUS<br />
SUn 1002 PLUS<br />
SUn 3002 PLUS<br />
Regardless its incredible low price, the SUN PLUS ESCs would be<br />
a real “red” high end KONTRONIK ESC. Made to control brushed<br />
motors it keeps nearly no wishes open. Compare it – a SUN PLUS<br />
is an absolute reliable partner.<br />
• The Mode Programming System of the SUN PLUS line allows<br />
to select an operating mode, which updates all controlable<br />
settings to optimal values. There is no need to program each<br />
single ESC parameter – such as EMF brake, maximum RPM or<br />
undervoltage cut off. Instead, you only select the type of your<br />
model.<br />
• Another essential highlight of the SUNs is the protection<br />
against reverse polarity. If plus and minus are swapped when<br />
connecting the battery, no damage will occur.<br />
• Of course the SUNs have an integrated LiPo Mode to protect<br />
LiPo batteries from exhaustive discharge.<br />
• The Heli Mode provides an Automatic Power Compensation.<br />
APC was develloped by KONTRONIK and is available only in<br />
SUN PLUS ESCs. It compensates the decreasing battery voltage<br />
by increasing the motor current. In Heli Mode most protection<br />
circuits are deactivated. No objectionable cut-off can<br />
risk flight safety.<br />
• Also integrated is a RC-Car Mode which offers a proportional<br />
brake for precise braking and an immediate throttle response<br />
for fast acceleration.<br />
• The programming of the SUN PLUS ESCs can also be done by<br />
PROGCARD which allows to adjust all parameters on the flying<br />
field without a computer.<br />
• Due to the 2 A BEC all SUN PLUS are prepared for an adequate<br />
supply of maximum 4 servos.<br />
• SUN PLUS ESCs come with the active free-wheeling circuit<br />
which means they have a full part load capability.<br />
• The level for the low voltage cut-off is calculated automatical-<br />
ly when the battery pack is connected to the ESC.<br />
• The performance and integrity of the unit are maintained by<br />
intelligent protection features. By measuring the temperature<br />
of the ESC, power to the motor is reduced if an overload is<br />
detected.<br />
SUN 1002<br />
PLUS<br />
SUN 3002<br />
PLUS<br />
SUN 4002<br />
PLUS<br />
Zellenzahl (LiPo) 2-3 2-3 2-3 Cell count (LiPo)<br />
Zellenzahl (niCd / niMH) 6-12 6-12 6-12 Cell count (niCd / niMH)<br />
Spannungsbereich [V] 6-16 6-16 6-16 operating voltage [V]<br />
Dauerstrom [A] (2,4 Ah Akku) 18 30 40 Continuous current [A] (2.4 Ah battery)<br />
Maximal Strom [A] (15 sek) 22 40 50 Maximum current [A] (15 sec)<br />
Maße [mm] Länge x Breite x Höhe 35 x 26 x 6 35 x 26 x 6 35 x 26 x 6 Size [mm] length x width x height<br />
Gewicht [g] ohne Kabel 9 9 9 Weight [g] without cables<br />
Gewicht [g] mit Kabel 22 23 23 Weight [g] with cables<br />
Kabelquerschnitt [mm 2 ] 1.5 2.5 2.5 Cable cross-section [mm 2 ]<br />
BEC / opto BEC BEC BEC BEC / opto<br />
BEC Belastbarkeit maximal [A] 2 2 2 BEC current maximum [A]<br />
BEC kurzschlussfest P P P BEC short circuit protection<br />
LiPo-Modus P P P LiPo Mode<br />
Auto-Programmier-Modus P P P Auto Programming Mode<br />
Modusprogrammierung P P P Mode programming<br />
ProGCArD fähig P P P ProGCArD ability<br />
Gasnachregelung APC P P P Automatic Power Compensation APC<br />
EMK-Bremse abschaltbar P P P EMF brake can be disabled<br />
Proportionale Bremse (rC-Car) P P P Proportional brake (rC car)<br />
Verpolschutz P P P reversal polarity protection<br />
Kurzschlussschutz P P P Short circuit protection<br />
Anlaufschutz P P P False start protection<br />
Strombegrenzung P P P Current limiting<br />
Übertemperaturschutz – – – overtemperature protection<br />
Unterspannungsabschaltung P P P Undervoltage cutoff<br />
– ” – mit automat. Anpassung an Zellenzahl Li-ion / LiPo / niCd / niMh – ” – with autom. adjustment for cell count<br />
Aktiver Freilauf P P P Active free wheeling circuit<br />
Bestellnummer 6105 6305 6405 Order #