psibarP in7Troubleshooting7.1 Replacing the Rupture Disc☞When the maximum allowable air supply pressure is exceeded, the reservoir is depressurized by thebursting of the rupture disc. The punctured rupture disc must be replaced.• Loosen the reservoir knob 2 and remove thereservoir lid 1.• Remove the screws and open the housing.Loctite (Ireland) Ltd.Made in Germany• Remove the rupture disc screw.• Replace the punctured rupture disc with a newone.Replace and tighten the rupture disc screw.Tightening torque: maximum 20 NmAffix the supplied type plate.20 Nm• Close the housing. Insert and tighten the screws.8Documentation8.1 Accessories and Spare PartsPos. No. Description Loctite Order No.– 2 l-<strong>Reservoir</strong> Spare Part Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97253(1 O-Ring, silicone grease, 3 handles, 3 dripcups)– Rupture Disc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97251– Filter Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9712026