Page 24 of <strong>ETA</strong>-<strong>10</strong>/<strong>0425</strong>, issued on 13.12.20<strong>10</strong>, English translation prepared by ZAG<br />

Base material hollow masonry: Hollow clay brick Leopard Brique Perforèe category 1-HD<br />

Table 15.1: Brick data<br />

Description of brick<br />

Type of brick<br />

Hollow clay brick -<br />

Leopard BP category 1-HD<br />

Bulk density ρ ≥ [kg/m 3 ] 1,3<br />

Standard EN 771-1<br />

Producer of brick<br />

Pacema Groupe Wienerberge<br />

F- 67087 Strasbourg<br />

Format (measurement) [mm] ≥ 220/120/54<br />

Minimum thickness of member hmin [mm] 120<br />

Table 15.2: Installation parameters<br />

Anchor size FM-X5 <strong>10</strong><br />

Drill hole diameter d0 [mm] <strong>10</strong><br />

Cutting diameter of drill bit dcut ≤ [mm] <strong>10</strong>,45<br />

Depth of drill hole to deepest point h1 ≥ [mm] 80<br />

Drill method [-] Rotary drilling<br />

Overal plastic embedment depth hnom = [mm] 70<br />

Diameter of clearance hole in the fixture df [mm] <strong>10</strong>,5<br />

1)<br />

Table 15.3: Characteristic resistance FRk for single anchor<br />

Hollow clay brick - Leopard BP category<br />

1HD fb ≥ 30 MPa<br />

Characteristic resistance FRk<br />

Anchor size FM-X5 <strong>10</strong><br />

24°C 3) /40°C 4) [kN] 1,5<br />

50°C 3) /80°C 4) [kN] 0,9<br />

Partial safety factor γMm 2) [-] 2,5<br />

1) Characteristic resistance FRk for tension, shear or combined tension and shear loading. The characteristic resistance is valid for<br />

single plastic anchor or for group of two or four plastic anchors with a spacing equal or larger than the minimum spacing smin<br />

according to Table 18. The specific conditions for the design method have to be considered according to chapter 4.2.1.5 of the <strong>ETA</strong>.<br />

2) IN absence of other national regulations<br />

3) Maximum long term temperature<br />

FM-X5<br />

Hollow masonry: Hollow clay brick -<br />

Leopard BP category 1-HD<br />

Brick data, installation parameters, characteristic<br />

resistance<br />

Annex 13<br />

of the <strong>European</strong> <strong>Technical</strong><br />

<strong>Approval</strong><br />

<strong>ETA</strong>–<strong>10</strong>/<strong>0425</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!