You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
|<br />
HORECA GASTRO GRINDER<br />
Alarm Record<br />
COVER OPEN<br />
LOW VOLTAGE<br />
Cause<br />
• Magnet switch<br />
open.<br />
• <strong>Grinder</strong>’s cover<br />
open.<br />
• Switch’s plug<br />
not connected<br />
at the processor<br />
board.<br />
• Strand of<br />
switch defective.<br />
• Magnet switch<br />
defective.<br />
• Contact magnet<br />
in cover<br />
missing.<br />
Correction<br />
• After closing the magnet<br />
switch press PROG-button.<br />
<strong>Grinder</strong>s are not blocked.<br />
• Check the plug/socket<br />
of the switch for correct<br />
position.<br />
• Bridge the contact in order<br />
to rule out defective processor<br />
board.<br />
• Test new magnet switch<br />
• Glue in a new contact<br />
magnet into the cover.<br />
• Main power • Switch off and on the<br />
board runs at grinder.<br />
35% under nor- • Check mains voltage.<br />
mal operation. Check junction box.<br />
• Power consumption<br />
at<br />
outlet too high.<br />
• Mains voltage<br />
too low.<br />
9. Spare Parts<br />
Spare parts are usually ordered from your customer service centre<br />
or your local dealer. To ensure quick and correct processing of your<br />
order, the following information is absolutely essential:<br />
1. Type designation, serial number and voltage of the grinder (on<br />
the rating plate underneath the grinder).<br />
2. An exact description of the part to be replaced or the article<br />
number.