NON CONTINUOUS END CONNECTION<br />
Floor Joists to line through with Wall Stud.<br />
CONTINUOUS MID-SPAN CONNECTION<br />
Structural Sections Framing ‘F’ Series Joist<br />
reinforcement screw fixed back-to-back,<br />
as determined by structural calculations.<br />
CONTINUOUS MID-SPAN OR END<br />
CONNECTION<br />
Short length of joist section screw fixed to back of joist,<br />
as determined by structural calculations.<br />
BLOCK WORK CONNECTION<br />
LATERAL BRACING<br />
Structural Sections Framing ‘F’ Series Floor joists to be<br />
braced every 4th pair and at end pairs + lateral bracing<br />
straps B38 fixed to lower flanges (only) at 2400mm max.<br />
unrestrained length. Joist top flange is restrained from<br />
screw fixing of floor decking. See blocking detail page 17.<br />
Span x 0.12 or<br />
minimum<br />
320mm.<br />
Span x 0.12 or<br />
minimum<br />
320mm.<br />
Blockwork<br />
STRUCTURALSECTIONSFRAMING<br />
FLOORJOISTS<br />
Track Section to top of stud wall or<br />
primary support.<br />
Structural Sections Framing ‘F’ Series Floor Joists<br />
screw fixed back-to-back, as determined by<br />
structural calculations.<br />
Structural Sections Framing ‘F’ Series Wall Stud (If<br />
appropriate).<br />
Track Section to top of stud wall or<br />
primary support.<br />
Structural Sections Framing ‘F’ Series Floor Joists<br />
continuous over wall or stud wall.<br />
Structural Sections Framing ‘F’ Series Wall Stud<br />
(If appropriate).<br />
JOIST REINFORCEMENT<br />
Joist web stiffening reinforces joists and prevents web<br />
crippling at the point of load concentrations.<br />
Reinforcement enables the joist to carry the allowable<br />
loads shown in the published span tables on page 24.<br />
N.B. Joist reinforcement is also required where the<br />
centre of a 100x40mm service slot occurs less than<br />
300mm from the edge of bearing or concentrated load.<br />
Structural Sections Framing ‘F’ Series Wall Stud<br />
(If appropriate).<br />
Deep Track Section (HT series) fixed to blockwork<br />
in accordance with structural calculations.<br />
www.hadleygroup.co.uk<br />