NON CONTINUOUS END CONNECTION<br />

Floor Joists to line through with Wall Stud.<br />

CONTINUOUS MID-SPAN CONNECTION<br />

Structural Sections Framing ‘F’ Series Joist<br />

reinforcement screw fixed back-to-back,<br />

as determined by structural calculations.<br />

CONTINUOUS MID-SPAN OR END<br />

CONNECTION<br />

Short length of joist section screw fixed to back of joist,<br />

as determined by structural calculations.<br />

BLOCK WORK CONNECTION<br />

LATERAL BRACING<br />

Structural Sections Framing ‘F’ Series Floor joists to be<br />

braced every 4th pair and at end pairs + lateral bracing<br />

straps B38 fixed to lower flanges (only) at 2400mm max.<br />

unrestrained length. Joist top flange is restrained from<br />

screw fixing of floor decking. See blocking detail page 17.<br />

Span x 0.12 or<br />

minimum<br />

320mm.<br />

Span x 0.12 or<br />

minimum<br />

320mm.<br />

Blockwork<br />

STRUCTURALSECTIONSFRAMING<br />

FLOORJOISTS<br />

Track Section to top of stud wall or<br />

primary support.<br />

Structural Sections Framing ‘F’ Series Floor Joists<br />

screw fixed back-to-back, as determined by<br />

structural calculations.<br />

Structural Sections Framing ‘F’ Series Wall Stud (If<br />

appropriate).<br />

Track Section to top of stud wall or<br />

primary support.<br />

Structural Sections Framing ‘F’ Series Floor Joists<br />

continuous over wall or stud wall.<br />

Structural Sections Framing ‘F’ Series Wall Stud<br />

(If appropriate).<br />

JOIST REINFORCEMENT<br />

Joist web stiffening reinforces joists and prevents web<br />

crippling at the point of load concentrations.<br />

Reinforcement enables the joist to carry the allowable<br />

loads shown in the published span tables on page 24.<br />

N.B. Joist reinforcement is also required where the<br />

centre of a 100x40mm service slot occurs less than<br />

300mm from the edge of bearing or concentrated load.<br />

Structural Sections Framing ‘F’ Series Wall Stud<br />

(If appropriate).<br />

Deep Track Section (HT series) fixed to blockwork<br />

in accordance with structural calculations.<br />

www.hadleygroup.co.uk<br />