Handling and installation of FR cable<br />

Minimum bending radius<br />

14<br />

Type of cable Unarmoured Armoured<br />

Number of <strong>co</strong>res Single <strong>co</strong>re Multi<strong>co</strong>re<br />

300/500V and<br />

600/1000V cable<br />

where D: diameter of cable<br />

8D 6D 10D<br />

Side wall pressure to cable<br />

Permissable maximum side wall pressure to the cable at bending point during installattion is 500kgf/m.<br />

Side wall<br />

pressure =<br />

to cable<br />

Pulling tension (kgf)<br />

Bending radius (m)<br />

T<br />

=<br />

R<br />

Permissable maximum pulling tension (T)<br />

Conductor (Tension kgf)<br />

Copper 7 x (No. of <strong>co</strong>res) x (cross-sectional area of <strong>co</strong>nductor)<br />

Drum handling<br />

Handle the drums with care! It is always re<strong>co</strong>mmended and a must with heavy drums - to lift drums<br />

with a fork-lift truck or a crane when removing them from the vehicle. Always take care to lower the<br />

drums into an upright position on their flanges.<br />

Unwinding Rewinding<br />

Right! From the top On to the top<br />

Re<strong>co</strong>mmended!<br />

Wrong! From the bottom On to the top<br />

Not Re<strong>co</strong>mmended!<br />

Prilling the cable this way<br />

causes kinking and<br />

possible damage.<br />

14<br />

Coursetiesing is not strictly<br />

necessary.