<strong>EVI</strong> 7 <strong>S9</strong> Solenoid System<br />
The <strong>EVI</strong>7 <strong>S9</strong> system by AMISCO<br />
includes a wide range of<br />
solenoids, coils and operators,<br />
designed for pneumatic valves.<br />
All solenoids of this system have<br />
the guide tube with a diameter<br />
of 9 mm and the plunger with<br />
a diameter of 8 mm.<br />
The system is designed<br />
for use with air.<br />
Please contact <strong>Amisco</strong> for use with other<br />
media. All given information are<br />
subjected to changes without notice.<br />
COIL<br />
The coil is available in different sizes and with different electrical terminations. Types, power and other<br />
characteristics are described in the following pages. All coils feature:<br />
heat resistant bobbin moulded with 30% glass filled thermoplastic polyester material<br />
class H wire 200°C according to IEC 60317-13<br />
built-in magnetic yoke made by low carbon iron<br />
encapsulation with high quality specially designed glass filled nylon (thermoset material on demand for 22 mm coil).<br />
The use of other materials is possible upon special agreements. All coils are rated to class F and to IP 65 (with connector).<br />
The coil is designed and constructed in accordance to EN 60204.1 and VDE 0580 and it is suitable for industrial ambient<br />
conditions. For use in special ambients with high humidity, we suggest the sealed or thermoset version; at any case,<br />
please, take contact with <strong>Amisco</strong>.<br />
The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex nA II 3 GD T4 or T5).<br />
OPERATOR<br />
Plunger and core are made by a magnetic stainless steel specially designed for solenoid applications.<br />
The guide tube is made with brass (stainless steel is possible upon special agreement).<br />
The plunger is normally equipped with NBR rubber seals. Other sealing materials like FKM are available upon demand.<br />
The armature assembly is designed for more than 10 6 cycles.<br />
COMPLETE SOLENOID OPERATOR<br />
The coil is fastened to the plungerguide tube by means of a<br />
knurled nut for ease of change over without interrupting the<br />
pneumatic circuit.<br />
The operator can be fixed to the valve body either by a M12x0.5<br />
thread (thread version), or by a mounting plate with screws<br />
(flange version). <strong>Amisco</strong> doesn't supply the plate.<br />
The suggested interface dimensions of the valve body are<br />
shown on the right side.<br />
Any change to the prescribed dimensions can effect the<br />
performances of the solenoid.<br />
1<br />
KNURLED NUT<br />
TOP CORE<br />
GUIDE TUBE<br />
PLUNGER<br />
MOUNTING PLATE<br />
THREAD VERSION FLANGE MOUNTING VERSION
SOLENOID SYSTEM<br />
for 2/2 and 3/2 way Normally Closed<br />
and Normally Open valves<br />
Coil <strong>EVI</strong> 7/9<br />
Electrical terminations<br />
Terminals AMP 6.3x0.8 width 11 mm<br />
Terminals AMP 6.3x0.8 width 11 mm Sealed version<br />
Terminals AMP 6.3x0.8 width 11 mm<br />
Sealed version Thermoset<br />
Flying leads<br />
Coil <strong>EVI</strong> 30/9<br />
Electrical termination<br />
Terminals DIN 43650 A<br />
Flying leads<br />
Operator <strong>S9</strong><br />
3/2 way NC flange<br />
3/2 way NC Thread<br />
2/2 way NC flange<br />
2/2 way NC Thread<br />
3/2 way NO flange (Top inlet)<br />
3/2 way NO Thread (Top inlet)<br />
3/2 way NO Thread (Bottom inlet)<br />
Note:<br />
Voltage tolerance: ± 10%<br />
Temperature range: –20°C ÷ +50°C<br />
Duty cycle: 100%<br />
Code<br />
0709S…<br />
0709F…<br />
0709E…<br />
0709C…<br />
Code<br />
3009D…<br />
3009C…<br />
Code<br />
09L...<br />
09F...<br />
09L...<br />
09F...<br />
09L...<br />
09F...<br />
09F...<br />
For different orifice sizes and pressures contact AMISCO S.p.A.<br />
Characteristics<br />
Rated power DC W<br />
Inrush power AC VA<br />
Rated power AC VA<br />
Coil temperature rise °C<br />
Copper temperature rise °C<br />
Characteristics<br />
Rated power DC W<br />
Inrush power AC VA<br />
Rated power AC VA<br />
Coil temperature rise °C<br />
Copper temperature rise °C<br />
Characteristics<br />
Inlet orifice Ø mm<br />
Exhaust orifice Ø mm<br />
Working pressure bar<br />
Inlet orifice Ø mm<br />
Working pressure bar<br />
Inlet orifice Ø mm<br />
Working pressure bar<br />
Inlet orifice Ø mm<br />
Working pressure bar<br />
Standard voltages: 24 - 110 - 230 VAC<br />
Other voltages on request<br />
12 - 24 VDC<br />
3<br />
35<br />
40<br />
2<br />
20<br />
25<br />
1,2<br />
1,45<br />
0÷10<br />
1,2<br />
0÷10<br />
1,45<br />
0÷7<br />
1,2<br />
0÷10<br />
DC AC (50 Hz) AC (60 Hz)<br />
4,2<br />
45<br />
50<br />
1,4<br />
1,45<br />
0÷10<br />
1,4<br />
0÷10<br />
1,45<br />
0÷7<br />
6,5<br />
70<br />
80<br />
1,5<br />
1,45<br />
0÷10<br />
1,5<br />
0÷10<br />
1,45<br />
0÷10<br />
7,5<br />
5<br />
45<br />
55<br />
1,2<br />
1,45<br />
0÷10<br />
1,2<br />
0÷10<br />
1,45<br />
0÷7<br />
1,2<br />
0÷10<br />
12,5<br />
8,5<br />
85<br />
95<br />
1,5<br />
1,45<br />
0÷10<br />
1,5<br />
0÷10<br />
1,45<br />
0÷10<br />
6,5<br />
4,2<br />
35<br />
45<br />
1,2<br />
1,45<br />
0÷10<br />
1,2<br />
0÷10<br />
1,45<br />
0÷7<br />
1,2<br />
0÷10<br />
10,5<br />
7<br />
70<br />
80<br />
DC AC (50 Hz) AC (60 Hz)<br />
4,5<br />
35<br />
50<br />
5,5<br />
3<br />
20<br />
25<br />
9<br />
5<br />
35<br />
45<br />
4,5<br />
2,5<br />
15<br />
20<br />
7,5<br />
4,2<br />
30<br />
35<br />
1,5<br />
1,45<br />
0÷10<br />
1,5<br />
0÷10<br />
1,45<br />
0÷10<br />
2
<strong>EVI</strong> 7/9 AMP 6,3x0,8<br />
(M3 Max Torque 0.6Nm)<br />
<strong>EVI</strong> 7/9 AMP 6,3x0,8 Sealed and Thermoset Version<br />
(M3 Max Torque 0.6Nm)<br />
<strong>EVI</strong> 7/9 Flying Leads<br />
3<br />
CODE 0709S...<br />
CODE 0709F...<br />
CODE 0709E...<br />
CODE 0709C...
<strong>EVI</strong> 30/9 DIN 43650 A<br />
(M3 Max Torque 0.6Nm)<br />
<strong>EVI</strong> 30/9 Flying Leads<br />
3009M Ex m<br />
CODE 3009D...<br />
CODE 3009C...<br />
CODE 3009M...<br />
4
3009 Ex m 94/9/EC ATEX<br />
AMISCO has completed the <strong>EVI</strong>7 <strong>S9</strong><br />
Solenoid System with a special coil for<br />
pneumatic applications in potentially<br />
explosive ambient (group II), that fullfills<br />
the requirements of EN 60079-0,<br />
EN60079-18, EN 61241-0, EN 61241-18,<br />
for protection mode “m”.<br />
The type 3009M Ex m coil is supplied with different lenght of<br />
cable up to 10 m.<br />
The coil is certified by CESI in thermal class T5 (with coil<br />
surface temperature max 100°C) or T4 (with coil surface<br />
temperature max 135°C).<br />
Ec-Type Examination Certificate number: CESI 02 ATEX 142 X<br />
and extension N° 02/07.<br />
Notification number: CESI 03 ATEX 075 Q.<br />
The protection is assured by a thermal fuse that, in case of<br />
demage, disconnects the coil from power.<br />
29.5 30<br />
5<br />
II<br />
2<br />
G<br />
D<br />
Ex<br />
mb<br />
mbD<br />
T5 or T4<br />
T95 or T130<br />
IP66<br />
Zone Category Description<br />
1<br />
21<br />
65.5<br />
2G<br />
2D<br />
12<br />
The product is developed to be used in ambients with<br />
temperature range from –15°C to +50°C, and it has a power<br />
consumption of 3.8W for type T4 and 3W for type T5.<br />
The coil fits all <strong>Amisco</strong> standard operators 3/2 or 2/2 way NC<br />
or NO, threaded or flange types.<br />
All main voltages are available.<br />
For other technical specifications see below and next pages.<br />
Specific marking of explosion protection<br />
Group II - Electrical apparatus for places with a potentially<br />
explosive atmosphere, other than mines susceptible to fire damp.<br />
Category 2 - see the board below.<br />
Explosive gas atmospheres.<br />
Explosive atmospheres in the presence of combustible dusts.<br />
The symbol Ex which indicates that the electrical apparatus<br />
corresponds to one of the protection type (EN 60079 – 0).<br />
Type of protection for gas – encapsulation m, level mb.<br />
Type of protection for dust (D) – encapsulation m, level mbD.<br />
Temperature class for gas.<br />
Maximum surface temperature for dust.<br />
The degrees of protection provided by an enclosure against,<br />
ingress of solid foreign objects, dust (first number)<br />
and water (second number).<br />
Equipment in this category is intended for use in areas where explosive atmospheres caused by air/gas mixture are likely to occur.<br />
Equipment in this category is intended for use in areas where explosive atmospheres caused by air/dust mixture are likely to occur.
SOLENOID SYSTEM Ex m<br />
for 2/2 and 3/2 way Normally Closed<br />
and Normally Open valves<br />
Coil 3009 M Code<br />
Characteristics<br />
Ex mb T5<br />
Ex mbD T95<br />
Ex mb T4<br />
Ex mbD T130<br />
Operator <strong>S9</strong><br />
3/2 way NC flange<br />
3/2 way NC thread<br />
2/2 way NC flange<br />
2/2 way NC thread<br />
3/2 way NO flange (Top Inlet)<br />
3/2 way NO thread (Top Inlet)<br />
Note:<br />
Voltage tolerance: ± 10%<br />
Temperature range: –15°C ÷ +50°C<br />
Duty cycle: 100%<br />
Performances<br />
3 W Coil - DC<br />
P<br />
12 bar<br />
10<br />
8<br />
6<br />
4<br />
2<br />
3009M…W.<br />
3009M…W.<br />
09L...<br />
09F...<br />
09L...<br />
09F...<br />
09L...<br />
09F...<br />
Rated power DC W<br />
Inrush power AC VA<br />
Rated power AC VA<br />
Coil temperature rise °C<br />
Copper temperature rise °C<br />
Rated power DC W<br />
Inrush power AC VA<br />
Rated power AC VA<br />
Coil temperature rise °C<br />
Copper temperature rise °C<br />
Inlet orifice Ø mm<br />
Exhaust orifice Ø mm<br />
Working pressure bar<br />
Inlet orifice Ø mm<br />
Working pressure bar<br />
Inlet orifice Ø mm<br />
Working pressure bar<br />
Standard voltages: 12 to 240 VAC - 50/60 Hz<br />
6 to 48 VDC<br />
For different orifice sizes and pressures contact AMISCO S.p.A.<br />
3,2 VA Coil - AC<br />
3,8 W Coil - DC<br />
Above-mentioned characteristics have to be intended only as indicative. They may change according to the tube design solutions.<br />
3<br />
35<br />
40<br />
DC AC (50 Hz) AC (60 Hz)<br />
Orifice 0 0,5 1 1,5 2 2,5 mm<br />
Orifice 0 0,5 1 1,5 2 2,5 mm<br />
P<br />
1,2<br />
1,45<br />
0-10<br />
1,2<br />
0-10<br />
1,45<br />
0-7<br />
12 bar<br />
10<br />
8<br />
6<br />
4<br />
2<br />
3,8<br />
50<br />
55<br />
1,5<br />
1,45<br />
0-10<br />
1,5<br />
0-10<br />
1,45<br />
0-10<br />
4,8<br />
3,2<br />
15<br />
30<br />
1,5<br />
14,5<br />
0-10<br />
1,5<br />
0-10<br />
1,45<br />
0-10<br />
4<br />
2,7<br />
10<br />
25<br />
1,5<br />
1,45<br />
0-10<br />
1,5<br />
0-10<br />
1,45<br />
0-10<br />
6
COIL CODING SPECIFICATIONS<br />
7<br />
TYPE<br />
07 = <strong>EVI</strong> 7<br />
30 = <strong>EVI</strong> 30<br />
COIL BORING<br />
09 = 9 mm<br />
ELECTRICAL CONNECTION<br />
for <strong>EVI</strong> 7<br />
S = AMP 6.3x0.8<br />
E = AMP 6.3x0.8 Epoxy Sealed Version<br />
F = AMP 6.3x0.8 Sealed Version<br />
C = Flying Leads<br />
CODE: X X 9 9 Y K 5 5 5 4 4 * *<br />
for <strong>EVI</strong> 30<br />
D = DIN 43650 A<br />
C = Flying Leads<br />
SUPPLY CURRENT<br />
A = Alternating current (A.C.)<br />
D = Direct current (D.C.)<br />
R = Rectified alternating current (R.A.C.)<br />
NOMINAL VOLTAGE<br />
Example: 024 = 24V<br />
220 = 220 V<br />
<strong>EVI</strong> 7 <strong>S9</strong> WINDING CODE <strong>EVI</strong> 30 <strong>S9</strong> WINDING CODE<br />
Nominal Voltage Power Winding Code Nominal Voltage Power Winding Code<br />
12VDC 3W 03<br />
4,2W 06<br />
6,5W 04<br />
24VDC 3W 03<br />
4,2W 06<br />
6,5W 04<br />
24VAC 5VA 01<br />
8,5VA 02<br />
110VAC 5VA 01<br />
8,5VA 02<br />
230VAC 5VA 03<br />
8,5VA 01<br />
Alternative possibilities for<br />
CUSTOMER LOGO<br />
12VDC 2W 01<br />
4,5W 05<br />
24VDC 2W 01<br />
4,5W 06<br />
24VAC 3VA 08<br />
5VA 02<br />
110VAC 3VA 07<br />
5VA 02<br />
230VAC 3VA 04<br />
5VA 01<br />
MARKING<br />
ZN = Standard - no logo<br />
AM = Standard + <strong>Amisco</strong> logo<br />
... = Customized marking
COIL 3009M Ex m CODING SPECIFICATIONS<br />
TYPE<br />
30 = <strong>EVI</strong> 30<br />
COIL BORING<br />
09 = 9 mm<br />
CODE: X X 9 9 Y K 5 5 5 4 4 * *<br />
TYPE OF PROTECTION<br />
M = Encapsulation<br />
SUPPLY CURRENT<br />
A = Alternating current (A.C.)<br />
D = Direct current (D.C.)<br />
NOMINAL VOLTAGE<br />
Example: 024 = 24V<br />
220 = 220 V<br />
TEMPERATURE CLASS<br />
W2 = T5 class for AC<br />
W3 = T5 class for DC<br />
W4 = T4 class for DC<br />
WIRE LENGHT<br />
01 = 1,2 m<br />
03 = 3 m<br />
05 = 5 m<br />
10 = 10 m<br />
8
EXAMPLES OF MAIN APPLICATIONS<br />
3/2 NC<br />
2/2 NC<br />
3/2 NO (Top Inlet)<br />
3/2 NO (Bottom Inlet)<br />
9<br />
3/2 NC & 3/2 NO (Top Inlet) Operator<br />
2/2 NC Operator<br />
3/2 NO (Bottom Inlet) Operator
COIL CODING SPECIFICATIONS<br />
Type<br />
FLANGE<br />
THREAD<br />
FASTENING NUTS (Note: tightening torque max 0.6 Nm)<br />
Plastic knurled nut<br />
Plastic knurled nut for<br />
protected exhaust<br />
Aluminium knurled nut<br />
Weavy washer<br />
Ø 8 DIN 137 type A<br />
Function<br />
3/2 NC<br />
2/2 NC<br />
3/2 NO<br />
(Top Inlet)<br />
3/2 NC<br />
2/2 NC<br />
3/2 NO<br />
(Top Inlet)<br />
3/2 NO<br />
(Bottom Inlet)<br />
Inlet orifice Ø<br />
1,2 mm<br />
1,4 mm<br />
1,5 mm<br />
1,2 mm<br />
1,4 mm<br />
1,5 mm<br />
1,45 mm<br />
1,2 mm<br />
1,4 mm<br />
1,5 mm<br />
1,2 mm<br />
1,4 mm<br />
1,5 mm<br />
1,45 mm<br />
1,2 mm<br />
Cod. 540238<br />
Cod. 540270<br />
Cod. 540201<br />
Cod. 535019<br />
Seals<br />
Operator Code<br />
NBR 09L02401A3CNN<br />
FKM 09L02401A3CVN<br />
NBR 09L07170A3CNN<br />
FKM 09L07171A3CVN<br />
NBR 09L02402A3CNN<br />
FKM 09L02402A3CVN<br />
NBR 09L02600A2CNN<br />
FKM 09L02600A2CVN<br />
NBR 09L02600A2CNN<br />
FKM 09L02600A2CVN<br />
NBR 09L02600A2CNN<br />
FKM 09L02600A2CVN<br />
NBR 09L02403A3ONN<br />
FKM 09L02403A3OVN<br />
NBR 09F07350A3CNN<br />
FKM 09F07350A3CVN<br />
NBR 09F07210A3CNN<br />
FKM 09F07212A3CVN<br />
NBR 09F07360A3CNN<br />
FKM 09F07360A3CVN<br />
NBR 09F07370A2CNN<br />
FKM 09F07370A2CVN<br />
NBR 09F07370A2CNN<br />
FKM 09F07370A2CVN<br />
NBR 09F07370A2CNN<br />
FKM 09F07370A2CVN<br />
NBR 09F07401A3ONN<br />
FKM 09F07403A3OVN<br />
NBR 09F11100A3ONN<br />
FKM 09F11101A3OVN<br />
10
www.amisco.it<br />
AMISCO S.p.A.<br />
Via Piaggio, 70<br />
20037 Paderno Dugnano (Mi)<br />
Italy<br />
Tel. +39 02.99.00.181<br />
Fax +39 02.99.00.18.60<br />
amisco@amisco.it<br />
Rev. 1/2011