05.03.2013 Views

EVI 7 S9 - Amisco

EVI 7 S9 - Amisco

EVI 7 S9 - Amisco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>EVI</strong> 7 <strong>S9</strong> Solenoid System<br />

The <strong>EVI</strong>7 <strong>S9</strong> system by AMISCO<br />

includes a wide range of<br />

solenoids, coils and operators,<br />

designed for pneumatic valves.<br />

All solenoids of this system have<br />

the guide tube with a diameter<br />

of 9 mm and the plunger with<br />

a diameter of 8 mm.<br />

The system is designed<br />

for use with air.<br />

Please contact <strong>Amisco</strong> for use with other<br />

media. All given information are<br />

subjected to changes without notice.<br />

COIL<br />

The coil is available in different sizes and with different electrical terminations. Types, power and other<br />

characteristics are described in the following pages. All coils feature:<br />

heat resistant bobbin moulded with 30% glass filled thermoplastic polyester material<br />

class H wire 200°C according to IEC 60317-13<br />

built-in magnetic yoke made by low carbon iron<br />

encapsulation with high quality specially designed glass filled nylon (thermoset material on demand for 22 mm coil).<br />

The use of other materials is possible upon special agreements. All coils are rated to class F and to IP 65 (with connector).<br />

The coil is designed and constructed in accordance to EN 60204.1 and VDE 0580 and it is suitable for industrial ambient<br />

conditions. For use in special ambients with high humidity, we suggest the sealed or thermoset version; at any case,<br />

please, take contact with <strong>Amisco</strong>.<br />

The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex nA II 3 GD T4 or T5).<br />

OPERATOR<br />

Plunger and core are made by a magnetic stainless steel specially designed for solenoid applications.<br />

The guide tube is made with brass (stainless steel is possible upon special agreement).<br />

The plunger is normally equipped with NBR rubber seals. Other sealing materials like FKM are available upon demand.<br />

The armature assembly is designed for more than 10 6 cycles.<br />

COMPLETE SOLENOID OPERATOR<br />

The coil is fastened to the plungerguide tube by means of a<br />

knurled nut for ease of change over without interrupting the<br />

pneumatic circuit.<br />

The operator can be fixed to the valve body either by a M12x0.5<br />

thread (thread version), or by a mounting plate with screws<br />

(flange version). <strong>Amisco</strong> doesn't supply the plate.<br />

The suggested interface dimensions of the valve body are<br />

shown on the right side.<br />

Any change to the prescribed dimensions can effect the<br />

performances of the solenoid.<br />

1<br />

KNURLED NUT<br />

TOP CORE<br />

GUIDE TUBE<br />

PLUNGER<br />

MOUNTING PLATE<br />

THREAD VERSION FLANGE MOUNTING VERSION


SOLENOID SYSTEM<br />

for 2/2 and 3/2 way Normally Closed<br />

and Normally Open valves<br />

Coil <strong>EVI</strong> 7/9<br />

Electrical terminations<br />

Terminals AMP 6.3x0.8 width 11 mm<br />

Terminals AMP 6.3x0.8 width 11 mm Sealed version<br />

Terminals AMP 6.3x0.8 width 11 mm<br />

Sealed version Thermoset<br />

Flying leads<br />

Coil <strong>EVI</strong> 30/9<br />

Electrical termination<br />

Terminals DIN 43650 A<br />

Flying leads<br />

Operator <strong>S9</strong><br />

3/2 way NC flange<br />

3/2 way NC Thread<br />

2/2 way NC flange<br />

2/2 way NC Thread<br />

3/2 way NO flange (Top inlet)<br />

3/2 way NO Thread (Top inlet)<br />

3/2 way NO Thread (Bottom inlet)<br />

Note:<br />

Voltage tolerance: ± 10%<br />

Temperature range: –20°C ÷ +50°C<br />

Duty cycle: 100%<br />

Code<br />

0709S…<br />

0709F…<br />

0709E…<br />

0709C…<br />

Code<br />

3009D…<br />

3009C…<br />

Code<br />

09L...<br />

09F...<br />

09L...<br />

09F...<br />

09L...<br />

09F...<br />

09F...<br />

For different orifice sizes and pressures contact AMISCO S.p.A.<br />

Characteristics<br />

Rated power DC W<br />

Inrush power AC VA<br />

Rated power AC VA<br />

Coil temperature rise °C<br />

Copper temperature rise °C<br />

Characteristics<br />

Rated power DC W<br />

Inrush power AC VA<br />

Rated power AC VA<br />

Coil temperature rise °C<br />

Copper temperature rise °C<br />

Characteristics<br />

Inlet orifice Ø mm<br />

Exhaust orifice Ø mm<br />

Working pressure bar<br />

Inlet orifice Ø mm<br />

Working pressure bar<br />

Inlet orifice Ø mm<br />

Working pressure bar<br />

Inlet orifice Ø mm<br />

Working pressure bar<br />

Standard voltages: 24 - 110 - 230 VAC<br />

Other voltages on request<br />

12 - 24 VDC<br />

3<br />

35<br />

40<br />

2<br />

20<br />

25<br />

1,2<br />

1,45<br />

0÷10<br />

1,2<br />

0÷10<br />

1,45<br />

0÷7<br />

1,2<br />

0÷10<br />

DC AC (50 Hz) AC (60 Hz)<br />

4,2<br />

45<br />

50<br />

1,4<br />

1,45<br />

0÷10<br />

1,4<br />

0÷10<br />

1,45<br />

0÷7<br />

6,5<br />

70<br />

80<br />

1,5<br />

1,45<br />

0÷10<br />

1,5<br />

0÷10<br />

1,45<br />

0÷10<br />

7,5<br />

5<br />

45<br />

55<br />

1,2<br />

1,45<br />

0÷10<br />

1,2<br />

0÷10<br />

1,45<br />

0÷7<br />

1,2<br />

0÷10<br />

12,5<br />

8,5<br />

85<br />

95<br />

1,5<br />

1,45<br />

0÷10<br />

1,5<br />

0÷10<br />

1,45<br />

0÷10<br />

6,5<br />

4,2<br />

35<br />

45<br />

1,2<br />

1,45<br />

0÷10<br />

1,2<br />

0÷10<br />

1,45<br />

0÷7<br />

1,2<br />

0÷10<br />

10,5<br />

7<br />

70<br />

80<br />

DC AC (50 Hz) AC (60 Hz)<br />

4,5<br />

35<br />

50<br />

5,5<br />

3<br />

20<br />

25<br />

9<br />

5<br />

35<br />

45<br />

4,5<br />

2,5<br />

15<br />

20<br />

7,5<br />

4,2<br />

30<br />

35<br />

1,5<br />

1,45<br />

0÷10<br />

1,5<br />

0÷10<br />

1,45<br />

0÷10<br />

2


<strong>EVI</strong> 7/9 AMP 6,3x0,8<br />

(M3 Max Torque 0.6Nm)<br />

<strong>EVI</strong> 7/9 AMP 6,3x0,8 Sealed and Thermoset Version<br />

(M3 Max Torque 0.6Nm)<br />

<strong>EVI</strong> 7/9 Flying Leads<br />

3<br />

CODE 0709S...<br />

CODE 0709F...<br />

CODE 0709E...<br />

CODE 0709C...


<strong>EVI</strong> 30/9 DIN 43650 A<br />

(M3 Max Torque 0.6Nm)<br />

<strong>EVI</strong> 30/9 Flying Leads<br />

3009M Ex m<br />

CODE 3009D...<br />

CODE 3009C...<br />

CODE 3009M...<br />

4


3009 Ex m 94/9/EC ATEX<br />

AMISCO has completed the <strong>EVI</strong>7 <strong>S9</strong><br />

Solenoid System with a special coil for<br />

pneumatic applications in potentially<br />

explosive ambient (group II), that fullfills<br />

the requirements of EN 60079-0,<br />

EN60079-18, EN 61241-0, EN 61241-18,<br />

for protection mode “m”.<br />

The type 3009M Ex m coil is supplied with different lenght of<br />

cable up to 10 m.<br />

The coil is certified by CESI in thermal class T5 (with coil<br />

surface temperature max 100°C) or T4 (with coil surface<br />

temperature max 135°C).<br />

Ec-Type Examination Certificate number: CESI 02 ATEX 142 X<br />

and extension N° 02/07.<br />

Notification number: CESI 03 ATEX 075 Q.<br />

The protection is assured by a thermal fuse that, in case of<br />

demage, disconnects the coil from power.<br />

29.5 30<br />

5<br />

II<br />

2<br />

G<br />

D<br />

Ex<br />

mb<br />

mbD<br />

T5 or T4<br />

T95 or T130<br />

IP66<br />

Zone Category Description<br />

1<br />

21<br />

65.5<br />

2G<br />

2D<br />

12<br />

The product is developed to be used in ambients with<br />

temperature range from –15°C to +50°C, and it has a power<br />

consumption of 3.8W for type T4 and 3W for type T5.<br />

The coil fits all <strong>Amisco</strong> standard operators 3/2 or 2/2 way NC<br />

or NO, threaded or flange types.<br />

All main voltages are available.<br />

For other technical specifications see below and next pages.<br />

Specific marking of explosion protection<br />

Group II - Electrical apparatus for places with a potentially<br />

explosive atmosphere, other than mines susceptible to fire damp.<br />

Category 2 - see the board below.<br />

Explosive gas atmospheres.<br />

Explosive atmospheres in the presence of combustible dusts.<br />

The symbol Ex which indicates that the electrical apparatus<br />

corresponds to one of the protection type (EN 60079 – 0).<br />

Type of protection for gas – encapsulation m, level mb.<br />

Type of protection for dust (D) – encapsulation m, level mbD.<br />

Temperature class for gas.<br />

Maximum surface temperature for dust.<br />

The degrees of protection provided by an enclosure against,<br />

ingress of solid foreign objects, dust (first number)<br />

and water (second number).<br />

Equipment in this category is intended for use in areas where explosive atmospheres caused by air/gas mixture are likely to occur.<br />

Equipment in this category is intended for use in areas where explosive atmospheres caused by air/dust mixture are likely to occur.


SOLENOID SYSTEM Ex m<br />

for 2/2 and 3/2 way Normally Closed<br />

and Normally Open valves<br />

Coil 3009 M Code<br />

Characteristics<br />

Ex mb T5<br />

Ex mbD T95<br />

Ex mb T4<br />

Ex mbD T130<br />

Operator <strong>S9</strong><br />

3/2 way NC flange<br />

3/2 way NC thread<br />

2/2 way NC flange<br />

2/2 way NC thread<br />

3/2 way NO flange (Top Inlet)<br />

3/2 way NO thread (Top Inlet)<br />

Note:<br />

Voltage tolerance: ± 10%<br />

Temperature range: –15°C ÷ +50°C<br />

Duty cycle: 100%<br />

Performances<br />

3 W Coil - DC<br />

P<br />

12 bar<br />

10<br />

8<br />

6<br />

4<br />

2<br />

3009M…W.<br />

3009M…W.<br />

09L...<br />

09F...<br />

09L...<br />

09F...<br />

09L...<br />

09F...<br />

Rated power DC W<br />

Inrush power AC VA<br />

Rated power AC VA<br />

Coil temperature rise °C<br />

Copper temperature rise °C<br />

Rated power DC W<br />

Inrush power AC VA<br />

Rated power AC VA<br />

Coil temperature rise °C<br />

Copper temperature rise °C<br />

Inlet orifice Ø mm<br />

Exhaust orifice Ø mm<br />

Working pressure bar<br />

Inlet orifice Ø mm<br />

Working pressure bar<br />

Inlet orifice Ø mm<br />

Working pressure bar<br />

Standard voltages: 12 to 240 VAC - 50/60 Hz<br />

6 to 48 VDC<br />

For different orifice sizes and pressures contact AMISCO S.p.A.<br />

3,2 VA Coil - AC<br />

3,8 W Coil - DC<br />

Above-mentioned characteristics have to be intended only as indicative. They may change according to the tube design solutions.<br />

3<br />

35<br />

40<br />

DC AC (50 Hz) AC (60 Hz)<br />

Orifice 0 0,5 1 1,5 2 2,5 mm<br />

Orifice 0 0,5 1 1,5 2 2,5 mm<br />

P<br />

1,2<br />

1,45<br />

0-10<br />

1,2<br />

0-10<br />

1,45<br />

0-7<br />

12 bar<br />

10<br />

8<br />

6<br />

4<br />

2<br />

3,8<br />

50<br />

55<br />

1,5<br />

1,45<br />

0-10<br />

1,5<br />

0-10<br />

1,45<br />

0-10<br />

4,8<br />

3,2<br />

15<br />

30<br />

1,5<br />

14,5<br />

0-10<br />

1,5<br />

0-10<br />

1,45<br />

0-10<br />

4<br />

2,7<br />

10<br />

25<br />

1,5<br />

1,45<br />

0-10<br />

1,5<br />

0-10<br />

1,45<br />

0-10<br />

6


COIL CODING SPECIFICATIONS<br />

7<br />

TYPE<br />

07 = <strong>EVI</strong> 7<br />

30 = <strong>EVI</strong> 30<br />

COIL BORING<br />

09 = 9 mm<br />

ELECTRICAL CONNECTION<br />

for <strong>EVI</strong> 7<br />

S = AMP 6.3x0.8<br />

E = AMP 6.3x0.8 Epoxy Sealed Version<br />

F = AMP 6.3x0.8 Sealed Version<br />

C = Flying Leads<br />

CODE: X X 9 9 Y K 5 5 5 4 4 * *<br />

for <strong>EVI</strong> 30<br />

D = DIN 43650 A<br />

C = Flying Leads<br />

SUPPLY CURRENT<br />

A = Alternating current (A.C.)<br />

D = Direct current (D.C.)<br />

R = Rectified alternating current (R.A.C.)<br />

NOMINAL VOLTAGE<br />

Example: 024 = 24V<br />

220 = 220 V<br />

<strong>EVI</strong> 7 <strong>S9</strong> WINDING CODE <strong>EVI</strong> 30 <strong>S9</strong> WINDING CODE<br />

Nominal Voltage Power Winding Code Nominal Voltage Power Winding Code<br />

12VDC 3W 03<br />

4,2W 06<br />

6,5W 04<br />

24VDC 3W 03<br />

4,2W 06<br />

6,5W 04<br />

24VAC 5VA 01<br />

8,5VA 02<br />

110VAC 5VA 01<br />

8,5VA 02<br />

230VAC 5VA 03<br />

8,5VA 01<br />

Alternative possibilities for<br />

CUSTOMER LOGO<br />

12VDC 2W 01<br />

4,5W 05<br />

24VDC 2W 01<br />

4,5W 06<br />

24VAC 3VA 08<br />

5VA 02<br />

110VAC 3VA 07<br />

5VA 02<br />

230VAC 3VA 04<br />

5VA 01<br />

MARKING<br />

ZN = Standard - no logo<br />

AM = Standard + <strong>Amisco</strong> logo<br />

... = Customized marking


COIL 3009M Ex m CODING SPECIFICATIONS<br />

TYPE<br />

30 = <strong>EVI</strong> 30<br />

COIL BORING<br />

09 = 9 mm<br />

CODE: X X 9 9 Y K 5 5 5 4 4 * *<br />

TYPE OF PROTECTION<br />

M = Encapsulation<br />

SUPPLY CURRENT<br />

A = Alternating current (A.C.)<br />

D = Direct current (D.C.)<br />

NOMINAL VOLTAGE<br />

Example: 024 = 24V<br />

220 = 220 V<br />

TEMPERATURE CLASS<br />

W2 = T5 class for AC<br />

W3 = T5 class for DC<br />

W4 = T4 class for DC<br />

WIRE LENGHT<br />

01 = 1,2 m<br />

03 = 3 m<br />

05 = 5 m<br />

10 = 10 m<br />

8


EXAMPLES OF MAIN APPLICATIONS<br />

3/2 NC<br />

2/2 NC<br />

3/2 NO (Top Inlet)<br />

3/2 NO (Bottom Inlet)<br />

9<br />

3/2 NC & 3/2 NO (Top Inlet) Operator<br />

2/2 NC Operator<br />

3/2 NO (Bottom Inlet) Operator


COIL CODING SPECIFICATIONS<br />

Type<br />

FLANGE<br />

THREAD<br />

FASTENING NUTS (Note: tightening torque max 0.6 Nm)<br />

Plastic knurled nut<br />

Plastic knurled nut for<br />

protected exhaust<br />

Aluminium knurled nut<br />

Weavy washer<br />

Ø 8 DIN 137 type A<br />

Function<br />

3/2 NC<br />

2/2 NC<br />

3/2 NO<br />

(Top Inlet)<br />

3/2 NC<br />

2/2 NC<br />

3/2 NO<br />

(Top Inlet)<br />

3/2 NO<br />

(Bottom Inlet)<br />

Inlet orifice Ø<br />

1,2 mm<br />

1,4 mm<br />

1,5 mm<br />

1,2 mm<br />

1,4 mm<br />

1,5 mm<br />

1,45 mm<br />

1,2 mm<br />

1,4 mm<br />

1,5 mm<br />

1,2 mm<br />

1,4 mm<br />

1,5 mm<br />

1,45 mm<br />

1,2 mm<br />

Cod. 540238<br />

Cod. 540270<br />

Cod. 540201<br />

Cod. 535019<br />

Seals<br />

Operator Code<br />

NBR 09L02401A3CNN<br />

FKM 09L02401A3CVN<br />

NBR 09L07170A3CNN<br />

FKM 09L07171A3CVN<br />

NBR 09L02402A3CNN<br />

FKM 09L02402A3CVN<br />

NBR 09L02600A2CNN<br />

FKM 09L02600A2CVN<br />

NBR 09L02600A2CNN<br />

FKM 09L02600A2CVN<br />

NBR 09L02600A2CNN<br />

FKM 09L02600A2CVN<br />

NBR 09L02403A3ONN<br />

FKM 09L02403A3OVN<br />

NBR 09F07350A3CNN<br />

FKM 09F07350A3CVN<br />

NBR 09F07210A3CNN<br />

FKM 09F07212A3CVN<br />

NBR 09F07360A3CNN<br />

FKM 09F07360A3CVN<br />

NBR 09F07370A2CNN<br />

FKM 09F07370A2CVN<br />

NBR 09F07370A2CNN<br />

FKM 09F07370A2CVN<br />

NBR 09F07370A2CNN<br />

FKM 09F07370A2CVN<br />

NBR 09F07401A3ONN<br />

FKM 09F07403A3OVN<br />

NBR 09F11100A3ONN<br />

FKM 09F11101A3OVN<br />

10


www.amisco.it<br />

AMISCO S.p.A.<br />

Via Piaggio, 70<br />

20037 Paderno Dugnano (Mi)<br />

Italy<br />

Tel. +39 02.99.00.181<br />

Fax +39 02.99.00.18.60<br />

amisco@amisco.it<br />

Rev. 1/2011