Short description of device, technical data - PS Antriebstechnik
Short description of device, technical data - PS Antriebstechnik
Short description of device, technical data - PS Antriebstechnik
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Technical <strong>data</strong><br />
BL12/4Q/2 BL08/4Q/2 BL04/4Q/2<br />
mains voltage 230V +1-10%, 50Hz-60Hz, grounded network<br />
(apparent) power input 3,0 KVA 2,0 KVA 1,0 KVA<br />
nominal Output current<br />
12A 8A 4A<br />
(block-commutation)<br />
max. (mechanical) power output 1,6 KW 1,1kW 0,55kW<br />
peak current output 2-fold rated current (can be connected; declines at a time<br />
constant <strong>of</strong> approx. 1 sec. to rated current)<br />
Permissible ambient temperature + 45°C (with free air circulation)<br />
Max. installation altitude<br />
without loss <strong>of</strong> power<br />
1500 m<br />
Permissible vibration 0,5g (effective) 10...50 Hz<br />
cycle frequency 16 KHz<br />
Operating mode Four-quadrant mode; power recovery in DC voltage<br />
intermediate circuit (or to the braking resistor)<br />
Holding torque at standstill Full rated torque<br />
Built-in braking resistor With external Max. 34 W mean braking power max.<br />
braking resistor (100)<br />
Max. braking power = rated motor power<br />
Control terminals Potential-free<br />
Output 3-phase, short-circuit-pro<strong>of</strong>, for motors with EMC<br />
= 170 V (peak value)<br />
Set point input (not inverting)<br />
-10V...+10V<br />
Set point input (inverting)<br />
-10V...+10V<br />
Input for max. torque<br />
0V ...+10V<br />
available options - 2nd mains input for control voltage<br />
- Braking resistor 100 150W/430W/1000W<br />
- Set point Integration, type SI-012<br />
- Position controller: LR<br />
- Pulse conditioning: IA/2<br />
- Pulse divider: IT<br />
- Synchronous control SYN<br />
- Interbus S<br />
- Positioning module CPM<br />
- Positioning module CMP-A<br />
speed feedback Incremental encoder or tachogenerator<br />
run-up protection system<br />
Monitoring for faulty or incorrectly connected<br />
(can be disconnected)<br />
incremental encoder or tachogenerator<br />
Incremental encoder output RS422 compatible (5 V external power supply required<br />
Analogue measuring outputs For speed and current in four quadrants<br />
Motor temperature monitoring PTC Thermistor or contact (break contact element)<br />
Lines to the Motor Low-cost standard cables (shielded)<br />
Max. length 50 m<br />
Protection Class IP20<br />
MC behaviour (emission): Acc. to DIN EN 61800-3, Class B<br />
Preconditions: Wired by EMC-competent personnel<br />
MC behaviour<br />
Acc. to DIN EN 61800-3, industrial environment<br />
(interference immunity)<br />
Preconditions: Wired by EMC-competent personnel