Trane Upflow/ Horizontal, Downflow - Bay Area Services
Trane Upflow/ Horizontal, Downflow - Bay Area Services
Trane Upflow/ Horizontal, Downflow - Bay Area Services
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
MODEL<br />
TUH1C080A9601A<br />
TYPE<br />
<strong>Upflow</strong> / <strong>Horizontal</strong><br />
RATINGS 2<br />
Input BTUH<br />
80,000<br />
Capacity BTUH (ICS) 3<br />
76,000<br />
AFUE (ICS)<br />
95.0<br />
Temp. rise (Min.-Max.) °F.<br />
30 - 60<br />
BLOWER DRIVE<br />
DIRECT<br />
Diameter - Width (In.)<br />
11 x 10<br />
No. Used<br />
1<br />
Speeds (No.)<br />
4<br />
CFM vs. in. w.g.<br />
See Fan Performance Table<br />
Motor HP<br />
3/4<br />
R.P.M.<br />
1100<br />
Volts / Ph / Hz<br />
115/1/60<br />
COMBUSTION FAN - Type<br />
Centrifugal<br />
Drive - No. Speeds<br />
Direct - 1<br />
Motor HP - RPM<br />
1/20 - 3450<br />
Volts / Ph / Hz<br />
115/1/60<br />
FLA<br />
0.71<br />
FILTER — Furnished?<br />
No<br />
Type Recommended<br />
High Velocity<br />
Hi Vel. (No.-Size-Thk.)<br />
1 - 20x25 - 1in.<br />
VENT PIPE DIAMETER — Min (In.) 56<br />
HEAT EXCHANGER<br />
3 Round<br />
Type-Fired<br />
-Unfired<br />
Aluminized Steel - Type I<br />
Gauge (Fired)<br />
ORIFICES — Main<br />
20<br />
Nat. Gas. Qty. — Drill Size<br />
4 — 45<br />
L.P. Gas Qty. — Drill Size<br />
4 — 56<br />
GAS VALVE<br />
PILOT SAFETY DEVICE<br />
Redundant - Single Stage<br />
Type<br />
Hot Surface Ignition<br />
BURNERS — Type<br />
Multiport Inshot<br />
Number<br />
4<br />
POWER CONN. — V / Ph / Hz 4<br />
115/1/60<br />
Ampacity (In Amps)<br />
13.5<br />
Max. Overcurrent Protection (Amps)<br />
20<br />
PIPE CONN. SIZE (IN.)<br />
1/2<br />
DIMENSIONS<br />
H x W x D<br />
Crated (In.)<br />
WEIGHT<br />
41-3/4 x 23 x 30-1/2<br />
Shipping (Lbs.) / Net (Lbs)<br />
171 / 160<br />
General<br />
Data<br />
Product Specifications 1<br />
TUH1C100A9481A<br />
<strong>Upflow</strong> / <strong>Horizontal</strong><br />
97,000<br />
92,150<br />
95.0<br />
35 - 65<br />
DIRECT<br />
10 x 10<br />
1<br />
4<br />
See Fan Performance Table<br />
1/2<br />
1075<br />
115/1/60<br />
Centrifugal<br />
Direct - 1<br />
1/20 - 3450<br />
115/1/60<br />
0.71<br />
No<br />
High Velocity<br />
1 - 20x25 - 1in.<br />
3 Round<br />
Aluminized Steel - Type I<br />
20<br />
5 — 45<br />
5 — 56<br />
Redundant - Single Stage<br />
Hot Surface Ignition<br />
Multiport Inshot<br />
5<br />
115/1/60<br />
12.5<br />
20<br />
1/2<br />
H x W x D<br />
41-3/4 x 23 x 30-1/2<br />
171 / 160<br />
TUH1D100A9601A<br />
<strong>Upflow</strong> / <strong>Horizontal</strong><br />
97,000<br />
92,150<br />
95.0<br />
35 - 65<br />
DIRECT<br />
11 x 10<br />
1<br />
4<br />
See Fan Performance Table<br />
3/4<br />
1100<br />
115/1/60<br />
Centrifugal<br />
Direct - 1<br />
1/20 - 3450<br />
115/1/60<br />
0.71<br />
No<br />
High Velocity<br />
1 - 24x25 - 1in.<br />
3 Round<br />
Aluminized Steel - Type I<br />
20<br />
5 — 45<br />
5 — 56<br />
Redundant - Single Stage<br />
Hot Surface Ignition<br />
Multiport Inshot<br />
5<br />
115/1/60<br />
12.9<br />
20<br />
1/2<br />
H x W x D<br />
41-3/4 x 26-1/2 x 30-1/2<br />
197 / 185<br />
TUH1D120A9601A<br />
<strong>Upflow</strong> / <strong>Horizontal</strong><br />
110,000<br />
104,500<br />
95.0<br />
40 - 70<br />
DIRECT<br />
11 x 10<br />
1<br />
4<br />
See Fan Performance Table<br />
3/4<br />
1100<br />
115/1/60<br />
Centrifugal<br />
Direct - 1<br />
1/20 - 3450<br />
115/1/60<br />
0.71<br />
No<br />
High Velocity<br />
1 - 24x25 - 1in.<br />
3 Round<br />
Aluminized Steel - Type I<br />
6 22-1836-07<br />
20<br />
6 — 45<br />
6 — 56<br />
Redundant - Single Stage<br />
Hot Surface Ignition<br />
Multiport Inshot<br />
6<br />
115/1/60<br />
12.9<br />
20<br />
1/2<br />
H x W x D<br />
41-3/4 x 26-1/2 x 30-1/2<br />
205 / 193<br />
Notes<br />
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3<br />
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea<br />
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500<br />
feet above sea level.<br />
3 Based on U.S. government standard tests.<br />
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.<br />
5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.<br />
6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".