20.03.2013 Views

Trane Upflow/ Horizontal, Downflow - Bay Area Services

Trane Upflow/ Horizontal, Downflow - Bay Area Services

Trane Upflow/ Horizontal, Downflow - Bay Area Services

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Upflow</strong>/ <strong>Horizontal</strong><br />

<strong>Downflow</strong>/<strong>Horizontal</strong><br />

Condensing, Direct Vent<br />

Gas-Fired Furnace<br />

XR 95<br />

TUH1B040A9241A, TUH1B060A9361A,<br />

TUH1B080A9421A, TUH1C080A9601A,<br />

TUH1C100A9481A, TUH1D100A9601A,<br />

TUH1D120A9601A, TDH1B040A9241A,<br />

TDH1B065A9421A, TDH1C085A9481A,<br />

TDH1D110A9601A<br />

Single-Stage Fan Assisted<br />

Combustion System<br />

*UH1<br />

UPFLOW<br />

*UH1<br />

UPFLOW/HORIZONTAL<br />

*DH1<br />

DOWNFLOW<br />

*DH1<br />

DOWNFLOW/HORIZONTAL<br />

PUB. NO. 22-1836-07


General<br />

Features<br />

NATURAL GAS MODELS<br />

Central Heating furnace designs are<br />

certified to ANSI Z21.47 / CSA 2.3 for<br />

both natural and L.P. gas. Limit setting<br />

and rating data were established and<br />

approved under standard rating conditions<br />

using American National Standards<br />

Institute standards.<br />

SAFE OPERATION<br />

The Integrated System Control has solid<br />

state devices, which continuously monitor<br />

for presence of flame, when the system is<br />

in the heating mode of operation. Dual<br />

solenoid combination gas valve and<br />

regulator provide extra safety.<br />

QUICK HEATING<br />

Durable, cycle tested, heavy gauge<br />

aluminized steel heat exchanger<br />

quickly transfers heat to provide warm<br />

conditioned air to the structure. Low<br />

energy power vent blower, to increase<br />

efficiency and provide a positive discharge<br />

of gas fumes to the outside.<br />

BURNERS<br />

Multiport Inshot burners will give years of<br />

quiet and efficient service. All models<br />

can be converted to L.P. gas without<br />

changing burners.<br />

INTEGRATED SYSTEM CONTROL<br />

Exclusively designed operational program<br />

provides total control of furnace<br />

limit sensors, blowers, gas valve, flame<br />

control and includes self diagnostics for<br />

ease of service. Also contains connection<br />

points for E.A.C./humidifier.<br />

AIR DELIVERY<br />

The four speed, direct drive blower<br />

motor, has sufficient airflow for most<br />

heating and cooling requirements, will<br />

switch from heating to cooling speeds on<br />

demand from room thermostat. The<br />

blower door safety switch will prevent or<br />

terminate furnace operation when the<br />

blower door is removed.<br />

STYLING<br />

Heavy gauge steel and “wrap-around”<br />

cabinet construction is used in the<br />

cabinet with baked-on enamel finish for<br />

strength and beauty. The heat exchanger<br />

section of the cabinet is completely<br />

lined with foil faced fiberglass<br />

insulation. This results in quiet and<br />

efficient operation due to the excellent<br />

acoustical and insulating qualities of<br />

fiberglass. Built-in bottom pan and<br />

alternate bottom, left or right side return<br />

air connection provision.<br />

FEATURES AND<br />

GENERAL OPERATION<br />

The XR 95 High Efficiency Gas Furnaces<br />

employ a Silicon Nitride Hot Surface<br />

Ignition system, which eliminates the<br />

waste of a constant burning pilot. The<br />

integrated system control lights the main<br />

burners upon a demand for heat from the<br />

room thermostat. Complete front service<br />

access.<br />

a. Low energy power venter<br />

b. Vent proving pressure switch.<br />

Features<br />

and Benefits<br />

XR 95 Standard Equipment<br />

• Power supply 115/1/60<br />

Convertible to horizontal<br />

Type 29-4C stainless steel secondary<br />

heat exchanger<br />

Inner blower doors<br />

Direct drive, 4-speed motors<br />

Silicon Nitride igniter with adaptive<br />

heat up<br />

Accessory hook-up capability –<br />

Hum and EAC<br />

Quiet induced draft blower<br />

Blower door safety switch<br />

Dual solenoid combination gas valve &<br />

regulator<br />

PVC venting – 1 or 2 pipe vent option<br />

Left/right gas connection<br />

Selectable cooling fan off delay<br />

eliminates need for BAY24X045 time<br />

delay relay<br />

Single wire twinning<br />

Integrated solid state control with selfdiagnostics<br />

24 volt fuse<br />

Manual reset burner box limit<br />

Optional extended warranties<br />

© 2011 <strong>Trane</strong> All Rights Reserved 2 22-1836-07


Contents<br />

22-1836-07 3<br />

General Features 2<br />

Features and Benefits 2<br />

XR 95 Standard Equipment 2<br />

XR 95 Optional Equipment 4<br />

General Data 5<br />

TUH1B040A9241A 5<br />

TUH1B060A9361A 5<br />

TUH1B080A9421A 5<br />

TUH1C080A9601A 6<br />

TUH1C100A9481A 6<br />

TUH1D100A9601A 6<br />

TUH1D120A9601A 6<br />

TDH1B040A9241A 7<br />

TDH1B065A9421A 7<br />

TDH1C085A9481A 7<br />

TDH1D110A9601A 7<br />

Performance Data 8<br />

Electrical Data 10<br />

Field Wiring 14<br />

Twinning Field Wiring 15<br />

Dimensions 16


Features and<br />

Benefits<br />

XR 95 Optional Equipment<br />

Comfort Control, XL803, Programmable 7 Day, 3-Ht, 2-Cl ........................................................................... TCONT803AS32DA [ ]<br />

Comfort Control, XR402, Electric, 3-Ht, 2-Cl (Non-programmable) .............................................................. TCONT402AN32DA [ ]<br />

For additional comfort control choices, see the product catalog or quick select handbook<br />

Propane Conversion Kit ....................................................................................................................................... BAYLPKT210B [ ]<br />

Propane Conversion Kit (stainless steel burners) ................................................................................................ BAYLPSS210B [ ]<br />

<strong>Downflow</strong> Subbase ................................................................................................................................................ BAYBASE205 [ ]<br />

Filter Access Door Kit .............................................................................................................................................. BAYFLTR206 [ ]<br />

Side Filter Rack ....................................................................................................................................................... BAYFLTR200 [ ]<br />

High Altitude Pressure Switch Kit TUH1B040, TDH1B040, TDH1C085 .........................................................BAYSWT01AHALTA [ ]<br />

High Altitude Pressure Switch Kit TUH1B060, TUH1D100, TUH1D120 .........................................................BAYSWT04AHALTA [ ]<br />

High Altitude Pressure Switch Kit TUH1B080, TUH1C100, TDH1D110 .........................................................BAYSWT05AHALTA [ ]<br />

High Altitude Pressure Switch Kit TUH1C080 ...............................................................................................BAYSWT11AHALTA [ ]<br />

High Altitude Pressure Switch Kit TDH1B065 ................................................................................................BAYSWT12AHALTA [ ]<br />

Concentric Vent Kit ......................................................................................................................................... BAYAIR30AVENTA [ ]<br />

Sidewall Vent Termination Kit .............................................................................................................................. BAYVENT200B [ ]<br />

Manufactured/Mobile Home Kit ...........................................................................................................................BAYMFGH100A [ ]<br />

4 22-1836-07


MODEL<br />

TYPE<br />

RATINGS 2<br />

Input BTUH<br />

Capacity BTUH (ICS) 3<br />

AFUE (ICS)<br />

Temp. rise (Min.-Max.) °F.<br />

BLOWER DRIVE<br />

Diameter - Width (In.)<br />

No. Used<br />

Speeds (No.)<br />

CFM vs. in. w.g.<br />

Motor HP<br />

R.P.M.<br />

Volts / Ph / Hz<br />

COMBUSTION FAN - Type<br />

Drive - No. Speeds<br />

Motor HP - RPM<br />

Volts / Ph / Hz<br />

FLA<br />

FILTER — Furnished?<br />

Type Recommended<br />

Hi Vel. (No.-Size-Thk.)<br />

VENT PIPE DIAMETER — Min (In.) 56<br />

HEAT EXCHANGER<br />

Type-Fired<br />

-Unfired<br />

Gauge (Fired)<br />

ORIFICES — Main<br />

Nat. Gas. Qty. — Drill Size<br />

L.P. Gas Qty. — Drill Size<br />

GAS VALVE<br />

PILOT SAFETY DEVICE<br />

Type<br />

BURNERS — Type<br />

Number<br />

POWER CONN. — V / Ph / Hz 4<br />

Ampacity (In Amps)<br />

Max. Overcurrent Protection (Amps)<br />

PIPE CONN. SIZE (IN.)<br />

DIMENSIONS<br />

Crated (In.)<br />

WEIGHT<br />

Shipping (Lbs.) / Net (Lbs)<br />

General<br />

Data<br />

Product Specifications 1<br />

TUH1B040A9241A<br />

<strong>Upflow</strong> / <strong>Horizontal</strong><br />

40,000<br />

38,000<br />

95.0<br />

30 - 60<br />

DIRECT<br />

9 x 7<br />

1<br />

4<br />

See Fan Performance Table<br />

1/5<br />

1075<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/55 - 3000<br />

115/1/60<br />

1.0<br />

No<br />

High Velocity<br />

1 - 17x25 - 1in.<br />

2 Round<br />

Aluminized Steel - Type I<br />

22-1836-07 5<br />

20<br />

2 — 45<br />

2 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

2<br />

115/1/60<br />

5.2<br />

15<br />

1/2<br />

H x W x D<br />

41-3/4 x 19-1/2 x 30-1/2<br />

139 / 129<br />

TUH1B060A9361A<br />

<strong>Upflow</strong> / <strong>Horizontal</strong><br />

60,000<br />

57,000<br />

95.0<br />

30 - 60<br />

DIRECT<br />

10 x 7<br />

1<br />

4<br />

See Fan Performance Table<br />

1/3<br />

1075<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/55 - 3450<br />

115/1/60<br />

1.75<br />

No<br />

High Velocity<br />

1 - 17x25 - 1in.<br />

2 Round<br />

Aluminized Steel - Type I<br />

20<br />

3 — 45<br />

3 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

3<br />

115/1/60<br />

9.2<br />

15<br />

1/2<br />

H x W x D<br />

41-3/4 x 19-1/2 x 30-1/2<br />

150 / 140<br />

TUH1B080A9421A<br />

<strong>Upflow</strong> / <strong>Horizontal</strong><br />

80,000<br />

76,000<br />

95.0<br />

35 - 65<br />

DIRECT<br />

11 x 8<br />

1<br />

4<br />

See Fan Performance Table<br />

1/2<br />

1075<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/24 - 3450<br />

115/1/60<br />

0.71<br />

No<br />

High Velocity<br />

1 - 17x25 - 1in.<br />

3 Round<br />

Aluminized Steel - Type I<br />

Notes<br />

1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3<br />

2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea<br />

level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet<br />

above sea level.<br />

3 Based on U.S. government standard tests.<br />

4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.<br />

5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.<br />

6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".<br />

20<br />

4 — 45<br />

4 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

4<br />

115/1/60<br />

10.2<br />

15<br />

1/2<br />

H x W x D<br />

41-3/4 x 19-1/2 x 30-1/2<br />

158 / 148


MODEL<br />

TUH1C080A9601A<br />

TYPE<br />

<strong>Upflow</strong> / <strong>Horizontal</strong><br />

RATINGS 2<br />

Input BTUH<br />

80,000<br />

Capacity BTUH (ICS) 3<br />

76,000<br />

AFUE (ICS)<br />

95.0<br />

Temp. rise (Min.-Max.) °F.<br />

30 - 60<br />

BLOWER DRIVE<br />

DIRECT<br />

Diameter - Width (In.)<br />

11 x 10<br />

No. Used<br />

1<br />

Speeds (No.)<br />

4<br />

CFM vs. in. w.g.<br />

See Fan Performance Table<br />

Motor HP<br />

3/4<br />

R.P.M.<br />

1100<br />

Volts / Ph / Hz<br />

115/1/60<br />

COMBUSTION FAN - Type<br />

Centrifugal<br />

Drive - No. Speeds<br />

Direct - 1<br />

Motor HP - RPM<br />

1/20 - 3450<br />

Volts / Ph / Hz<br />

115/1/60<br />

FLA<br />

0.71<br />

FILTER — Furnished?<br />

No<br />

Type Recommended<br />

High Velocity<br />

Hi Vel. (No.-Size-Thk.)<br />

1 - 20x25 - 1in.<br />

VENT PIPE DIAMETER — Min (In.) 56<br />

HEAT EXCHANGER<br />

3 Round<br />

Type-Fired<br />

-Unfired<br />

Aluminized Steel - Type I<br />

Gauge (Fired)<br />

ORIFICES — Main<br />

20<br />

Nat. Gas. Qty. — Drill Size<br />

4 — 45<br />

L.P. Gas Qty. — Drill Size<br />

4 — 56<br />

GAS VALVE<br />

PILOT SAFETY DEVICE<br />

Redundant - Single Stage<br />

Type<br />

Hot Surface Ignition<br />

BURNERS — Type<br />

Multiport Inshot<br />

Number<br />

4<br />

POWER CONN. — V / Ph / Hz 4<br />

115/1/60<br />

Ampacity (In Amps)<br />

13.5<br />

Max. Overcurrent Protection (Amps)<br />

20<br />

PIPE CONN. SIZE (IN.)<br />

1/2<br />

DIMENSIONS<br />

H x W x D<br />

Crated (In.)<br />

WEIGHT<br />

41-3/4 x 23 x 30-1/2<br />

Shipping (Lbs.) / Net (Lbs)<br />

171 / 160<br />

General<br />

Data<br />

Product Specifications 1<br />

TUH1C100A9481A<br />

<strong>Upflow</strong> / <strong>Horizontal</strong><br />

97,000<br />

92,150<br />

95.0<br />

35 - 65<br />

DIRECT<br />

10 x 10<br />

1<br />

4<br />

See Fan Performance Table<br />

1/2<br />

1075<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/20 - 3450<br />

115/1/60<br />

0.71<br />

No<br />

High Velocity<br />

1 - 20x25 - 1in.<br />

3 Round<br />

Aluminized Steel - Type I<br />

20<br />

5 — 45<br />

5 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

5<br />

115/1/60<br />

12.5<br />

20<br />

1/2<br />

H x W x D<br />

41-3/4 x 23 x 30-1/2<br />

171 / 160<br />

TUH1D100A9601A<br />

<strong>Upflow</strong> / <strong>Horizontal</strong><br />

97,000<br />

92,150<br />

95.0<br />

35 - 65<br />

DIRECT<br />

11 x 10<br />

1<br />

4<br />

See Fan Performance Table<br />

3/4<br />

1100<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/20 - 3450<br />

115/1/60<br />

0.71<br />

No<br />

High Velocity<br />

1 - 24x25 - 1in.<br />

3 Round<br />

Aluminized Steel - Type I<br />

20<br />

5 — 45<br />

5 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

5<br />

115/1/60<br />

12.9<br />

20<br />

1/2<br />

H x W x D<br />

41-3/4 x 26-1/2 x 30-1/2<br />

197 / 185<br />

TUH1D120A9601A<br />

<strong>Upflow</strong> / <strong>Horizontal</strong><br />

110,000<br />

104,500<br />

95.0<br />

40 - 70<br />

DIRECT<br />

11 x 10<br />

1<br />

4<br />

See Fan Performance Table<br />

3/4<br />

1100<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/20 - 3450<br />

115/1/60<br />

0.71<br />

No<br />

High Velocity<br />

1 - 24x25 - 1in.<br />

3 Round<br />

Aluminized Steel - Type I<br />

6 22-1836-07<br />

20<br />

6 — 45<br />

6 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

6<br />

115/1/60<br />

12.9<br />

20<br />

1/2<br />

H x W x D<br />

41-3/4 x 26-1/2 x 30-1/2<br />

205 / 193<br />

Notes<br />

1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3<br />

2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea<br />

level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500<br />

feet above sea level.<br />

3 Based on U.S. government standard tests.<br />

4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.<br />

5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.<br />

6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".


MODEL<br />

TYPE<br />

RATINGS 2<br />

Input BTUH<br />

Capacity BTUH (ICS) 3<br />

AFUE (ICS)<br />

Temp. rise (Min.-Max.) °F.<br />

BLOWER DRIVE<br />

Diameter - Width (In.)<br />

No. Used<br />

Speeds (No.)<br />

CFM vs. in. w.g.<br />

Motor HP<br />

R.P.M.<br />

Volts / Ph / Hz<br />

COMBUSTION FAN - Type<br />

Drive - No. Speeds<br />

Motor HP - RPM<br />

Volts / Ph / Hz<br />

FLA<br />

FILTER — Furnished?<br />

Type Recommended<br />

Hi Vel. (No.-Size-Thk.)<br />

TDH1B040A9241A<br />

<strong>Downflow</strong> / <strong>Horizontal</strong><br />

40,000<br />

38,000<br />

95.0<br />

30 - 60<br />

DIRECT<br />

10 x 7<br />

1<br />

4<br />

See Fan Performance Table<br />

1/5<br />

1080<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/55 - 3000<br />

115/1/60<br />

1.14<br />

No<br />

High Velocity<br />

2 - 14x20 - 1in.<br />

VENT PIPE DIAMETER — Min (In.) 56<br />

HEAT EXCHANGER<br />

2 Round<br />

Type-Fired<br />

-Unfired<br />

Aluminized Steel - Type I<br />

Gauge (Fired)<br />

ORIFICES — Main<br />

20<br />

Nat. Gas. Qty. — Drill Size<br />

L.P. Gas Qty. — Drill Size<br />

2 — 45<br />

2 — 56<br />

GAS VALVE<br />

PILOT SAFETY DEVICE<br />

Redundant - Single Stage<br />

Type<br />

Hot Surface Ignition<br />

BURNERS — Type<br />

Number<br />

Multiport Inshot<br />

2<br />

POWER CONN. — V / Ph / Hz 4<br />

Ampacity (In Amps)<br />

Max. Overcurrent Protection (Amps)<br />

115/1/60<br />

4.8<br />

15<br />

PIPE CONN. SIZE (IN.)<br />

1/2<br />

DIMENSIONS<br />

Crated (In.)<br />

WEIGHT<br />

H x W x D<br />

41-3/4 x 19-1/2 x 30-1/2<br />

Shipping (Lbs.) / Net (Lbs)<br />

145 / 135<br />

General<br />

Data<br />

Product Specifications 1<br />

TDH1B065A9421A<br />

<strong>Downflow</strong> / <strong>Horizontal</strong><br />

60,000<br />

57,000<br />

95.0<br />

25 - 55<br />

DIRECT<br />

11 x 8<br />

1<br />

4<br />

See Fan Performance Table<br />

1/2<br />

1075<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/25 - 3200<br />

115/1/60<br />

1.35<br />

No<br />

High Velocity<br />

2 - 14x20 - 1in.<br />

2 Round<br />

Aluminized Steel - Type I<br />

Notes<br />

1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3<br />

2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea<br />

level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500<br />

feet above sea level.<br />

3 Based on U.S. government standard tests.<br />

4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.<br />

5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.<br />

6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".<br />

22-1836-07 7<br />

20<br />

4 — 48<br />

4 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

4<br />

115/1/60<br />

11.4<br />

15<br />

1/2<br />

H x W x D<br />

41-3/4 x 19-1/2 x 30-1/2<br />

158 / 148<br />

TDH1C085A9481A<br />

<strong>Downflow</strong> / <strong>Horizontal</strong><br />

80,000<br />

76,000<br />

95.0<br />

30 - 60<br />

DIRECT<br />

11 x 10<br />

1<br />

4<br />

See Fan Performance Table<br />

1/2<br />

1075<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/20 - 3450<br />

115/1/60<br />

0.71<br />

No<br />

High Velocity<br />

2 - 16x20 - 1in.<br />

2.5 Round<br />

Aluminized Steel - Type I<br />

20<br />

5 — 48<br />

5 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

5<br />

115/1/60<br />

12.5<br />

20<br />

1/2<br />

H x W x D<br />

41-3/4 x 23 x 30-1/2<br />

171 / 160<br />

TDH1D110A9601A<br />

<strong>Downflow</strong> / <strong>Horizontal</strong><br />

110,000<br />

104,500<br />

95.0<br />

35 - 65<br />

DIRECT<br />

11 x 10<br />

1<br />

4<br />

See Fan Performance Table<br />

3/4<br />

1100<br />

115/1/60<br />

Centrifugal<br />

Direct - 1<br />

1/20 - 3450<br />

115/1/60<br />

0.71<br />

No<br />

High Velocity<br />

2 - 16x20 - 1in.<br />

2.5 Round<br />

Aluminized Steel - Type I<br />

20<br />

6 — 48<br />

6 — 56<br />

Redundant - Single Stage<br />

Hot Surface Ignition<br />

Multiport Inshot<br />

6<br />

115/1/60<br />

12.9<br />

20<br />

1/2<br />

H x W x D<br />

41-3/4 x 26-1/2 x 30-1/2<br />

205 / 193


Performance<br />

Data<br />

FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)<br />

MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90<br />

*UH1B040A9241A<br />

*UH1B060A9361A<br />

*UH1B080A9421A<br />

*UH1C080A9601A<br />

*UH1C100A9481A<br />

*UH1D100A9601A<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

*UH1D120A9601A<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

*= First letter may be "A" or "T"<br />

1043<br />

940<br />

837<br />

729<br />

1359<br />

1232<br />

1077<br />

926<br />

1646<br />

1366<br />

1175<br />

1004<br />

2235<br />

1921<br />

1618<br />

1334<br />

1982<br />

1892<br />

1759<br />

1593<br />

2339<br />

2045<br />

1719<br />

1436<br />

2380<br />

2042<br />

1695<br />

1402<br />

CFM VS. TEMPERATURE RISE<br />

Cubic Feet Per Minute (CFM)<br />

MODEL<br />

600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400<br />

*UH1B040A9241A 59 50 44 39 35<br />

*UH1B060A9361A 59 53 48 44 41 38<br />

*UH1B080A9421A 64 59 54 50 47 44 41<br />

*UH1C080A9601A 64 59 54 50 47 44 41<br />

*UH1C100A9481A 68 63 59 55 52 49 46 44<br />

992<br />

895<br />

798<br />

694<br />

1313<br />

1199<br />

1054<br />

913<br />

1611<br />

1356<br />

1159<br />

994<br />

2194<br />

1904<br />

1604<br />

1331<br />

1912<br />

1832<br />

1712<br />

1557<br />

2287<br />

2021<br />

1703<br />

1430<br />

2334<br />

2029<br />

1690<br />

1404<br />

*UH1D100A9601A 68 63 59 55 52 49 46 44 42 40 38 37<br />

*UH1D120A9601A<br />

*= First letter may be "A" or "T"<br />

70 66 62 59 56 53 50 48 46 44<br />

930<br />

841<br />

752<br />

657<br />

1264<br />

1161<br />

1027<br />

895<br />

1573<br />

1337<br />

1145<br />

997<br />

2152<br />

1888<br />

1591<br />

1327<br />

1836<br />

1765<br />

1660<br />

1521<br />

2235<br />

1996<br />

1693<br />

1430<br />

2287<br />

2016<br />

1684<br />

1406<br />

885<br />

791<br />

705<br />

600<br />

1204<br />

1116<br />

994<br />

871<br />

1530<br />

1311<br />

1130<br />

982<br />

2105<br />

1861<br />

1577<br />

1320<br />

1761<br />

1696<br />

1604<br />

1485<br />

2168<br />

1947<br />

1671<br />

1414<br />

2241<br />

1984<br />

1668<br />

1397<br />

812<br />

726<br />

649<br />

545<br />

1144<br />

1065<br />

953<br />

836<br />

1477<br />

1280<br />

1108<br />

963<br />

2057<br />

1835<br />

1563<br />

1313<br />

1679<br />

1621<br />

1536<br />

1433<br />

2100<br />

1897<br />

1649<br />

1398<br />

2193<br />

1952<br />

1652<br />

1387<br />

740<br />

650<br />

560<br />

478<br />

1079<br />

1004<br />

904<br />

792<br />

1421<br />

1243<br />

1081<br />

943<br />

1987<br />

1797<br />

1539<br />

1290<br />

1593<br />

1538<br />

1465<br />

1370<br />

2021<br />

1836<br />

1607<br />

1372<br />

2118<br />

1892<br />

1627<br />

1358<br />

647<br />

559<br />

438<br />

376<br />

1004<br />

934<br />

845<br />

733<br />

1360<br />

1197<br />

1045<br />

907<br />

1916<br />

1760<br />

1515<br />

1266<br />

1496<br />

1446<br />

1383<br />

1294<br />

1941<br />

1774<br />

1565<br />

1344<br />

2043<br />

1830<br />

1601<br />

1328<br />

518<br />

420<br />

305<br />

220<br />

919<br />

852<br />

768<br />

670<br />

1289<br />

1139<br />

993<br />

866<br />

1836<br />

1698<br />

1466<br />

1229<br />

1389<br />

1342<br />

1275<br />

1182<br />

1858<br />

1701<br />

1498<br />

1287<br />

1956<br />

1771<br />

1545<br />

1285<br />

457<br />

390<br />

279<br />

178<br />

812<br />

744<br />

666<br />

570<br />

1200<br />

1060<br />

929<br />

824<br />

1757<br />

1636<br />

1416<br />

1192<br />

1267<br />

1205<br />

1149<br />

1068<br />

1773<br />

1629<br />

1431<br />

1230<br />

1870<br />

1712<br />

1489<br />

1242<br />

8 22-1836-07


FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)<br />

MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90<br />

*DH1B040A9241A<br />

*DH1B065A9421A<br />

*DH1C085A9481A<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

4 - HIGH - Black<br />

3 - MED.-HIGH - Blue<br />

*DH1D110A9601A<br />

2 - MED.-LOW - Yellow<br />

1 - LOW - Red<br />

*= First letter may be "A" or "T"<br />

Performance<br />

Data<br />

CFM VS. TEMPERATURE RISE<br />

Cubic Feet Per Minute (CFM)<br />

MODEL<br />

600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400<br />

*DH1B040A9241A 59 50 44 39 35<br />

*DH1B065A9421A 75 66 59 53 48 44 41 38 35<br />

*DH1C085A9481A 70 64 59 54 50 47 44 41 39 37<br />

998<br />

856<br />

753<br />

647<br />

1501<br />

1442<br />

1346<br />

1225<br />

1835<br />

1726<br />

1581<br />

1401<br />

2147<br />

1995<br />

1712<br />

1424<br />

*DH1D110A9601A<br />

*= First letter may be "A" or "T"<br />

88 81 74 69 65 60 57 54 51 48 46<br />

965<br />

832<br />

728<br />

617<br />

1453<br />

1393<br />

1308<br />

1197<br />

1772<br />

1674<br />

1539<br />

1374<br />

2074<br />

1940<br />

1681<br />

1408<br />

22-1836-07 9<br />

922<br />

797<br />

694<br />

581<br />

1402<br />

1341<br />

1263<br />

1160<br />

1709<br />

1622<br />

1498<br />

1346<br />

2000<br />

1885<br />

1649<br />

1392<br />

870<br />

751<br />

650<br />

538<br />

1344<br />

1285<br />

1212<br />

1116<br />

1637<br />

1557<br />

1440<br />

1308<br />

1941<br />

1827<br />

1602<br />

1367<br />

807<br />

695<br />

596<br />

490<br />

1283<br />

1227<br />

1155<br />

1062<br />

1566<br />

1492<br />

1383<br />

1269<br />

1881<br />

1767<br />

1555<br />

1341<br />

735<br />

628<br />

533<br />

435<br />

1216<br />

1166<br />

1092<br />

1001<br />

1485<br />

1416<br />

1321<br />

1209<br />

1807<br />

1699<br />

1505<br />

1296<br />

653<br />

550<br />

460<br />

375<br />

1145<br />

1103<br />

1024<br />

931<br />

1405<br />

1340<br />

1258<br />

1148<br />

1732<br />

1631<br />

1455<br />

1251<br />

561<br />

462<br />

378<br />

308<br />

1068<br />

1037<br />

950<br />

853<br />

1313<br />

1252<br />

1172<br />

1075<br />

1655<br />

1547<br />

1381<br />

1188<br />

459<br />

363<br />

286<br />

235<br />

986<br />

968<br />

869<br />

766<br />

1222<br />

1164<br />

1085<br />

1001<br />

1576<br />

1462<br />

1307<br />

1124


TUH1 Wiring<br />

From Dwg. D343498 Rev. 2<br />

Electrical<br />

Data<br />

10 22-1836-07


TUH1 Schematic<br />

Electrical<br />

Data<br />

22-1836-07 11<br />

From Dwg. D343498 Rev. 2


Electrical<br />

Data<br />

From Dwg. D343814P01 Rev.0<br />

12 22-1836-07


Electrical<br />

Data<br />

22-1836-07 13<br />

From Dwg. D343814P01 Rev.0


OUTDOOR UNIT<br />

(NO TRANSFORMER)<br />

Field<br />

Wiring<br />

FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE<br />

1 STAGE HEATING, 1 STAGE COOLING<br />

USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT<br />

(OUTDOOR SECTION WITHOUT TRANSFORMER)<br />

B/C<br />

SEE<br />

NOTE 6<br />

SEE<br />

NOTE 8<br />

FURNACE<br />

B/C<br />

TO 115 V 1 PH.,<br />

60 HZ., POWER<br />

SUPPLY PER<br />

LOCAL CODES<br />

HUM SEE<br />

NOTE 5<br />

EAC SEE<br />

NOTE 5<br />

From drawing B340388 Rv 2<br />

14 22-1836-07


Twinning<br />

Field Wiring<br />

1 STAGE HEAT<br />

ONLY<br />

THERMOSTAT<br />

TWINNING CONNECTION DIAGRAM<br />

FOR TWINNING 1 STAGE FURNACES WITH<br />

SINGLE WIRE TWINNING FEATURE<br />

1 STAGE HEATING ONLY THERMOSTAT<br />

(WITH FAN SWITCH) FURNACE NO. 1 FURNACE NO. 2<br />

B/C<br />

OUTDOOR UNIT<br />

(WITH TRANSFORMER)<br />

RC<br />

ISOLATION RELAY<br />

(FIELD SUPPLIED)<br />

SEE NOTE 3<br />

OUTDOOR UNIT<br />

(NO TRANSFORMER)<br />

SEE NOTE 3<br />

TWIN TWIN<br />

B/C<br />

ISOLATION RELAY<br />

(FIELD SUPPLIED)<br />

SEE NOTE 4<br />

R1 R1<br />

22-1836-07 15<br />

BLOWER OPERATION OF<br />

UNIT NO. 2 IS SYNCRONIZED<br />

WITH UNIT NO. 1 VIA SIGNALS<br />

FROM TWIN CONNECTION.<br />

SEE NOTE 4<br />

B/C<br />

TWINNING CONNECTION DIAGRAM<br />

FOR TWINNING 1 STAGE FURNACES WITH<br />

SINGLE WIRE TWINNING FEATURE<br />

1 STAGE HEAT / 1 STAGE COOL THERMOSTAT<br />

1 STAGE<br />

HEATING / COOLING<br />

THERMOSTAT FURNACE NO. 1 FURNACE NO. 2<br />

B/C<br />

SEE NOTE 5<br />

TWIN TWIN<br />

B/C<br />

R1<br />

ISOLATION RELAY<br />

(FIELD SUPPLIED)<br />

SEE NOTE 4<br />

ISOLATION RELAY<br />

SEE NOTE 4<br />

BLOWER OPERATION OF<br />

UNIT NO. 2 IS SYNCRONIZED<br />

WITH UNIT NO. 1 VIA SIGNALS<br />

FROM TWIN CONNECTION.<br />

SEE NOTE 4<br />

B/C<br />

From Dwg. 21B341422 Rev. 3<br />

R1<br />

ISOLATION RELAY<br />

SEE NOTE 4<br />

From Dwg. 21B341423 Rev. 2


*UH1 OUTLINE DRAWING, UPFLOW / HORIZONTAL<br />

(ALL DIMENSIONS ARE IN INCHES)<br />

1. *UH1D120A9601 AND *UH1B080A9421 REQUIRE 3” DIAMETER VENT PIPE.<br />

*UH1C100A9481 & UH1D100A9601 REQUIRES 2-1/2” OR 3”<br />

DIAMETER VENT PIPE.<br />

2. DIAMETER OF VENT PIPE MAY BE LIMITED TO 2-1/2” OR 3”<br />

ON SOME MODELS AT DIFFERENT ALTITUDES. REFER TO THE<br />

VENT LENGTH TABLE FOR PROPER APPLICATION.<br />

Dimensions<br />

16 22-1836-07<br />

From Dwg. C341884


*DH1 OUTLINE DRAWING, DOWNFLOW / HORIZONTAL<br />

(ALL DIMENSIONS ARE IN INCHES)<br />

Dimensions<br />

22-1836-07 17<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

From Dwg. C341885 Rev. 7


<strong>Trane</strong><br />

6200 Troup Highway<br />

Tyler, TX 75707<br />

www.trane.com<br />

Literature Order Number 22-1836-07<br />

File Number 22-1836-07<br />

Supersedes 22-1836-05<br />

Date 08/11<br />

<strong>Trane</strong> has a policy of continuous product and product data improvement and it reserves the right to<br />

change design and specifications without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!