Reheater Isolating Device<br />
Features and Benefits<br />
Single seal<br />
preloading<br />
screw<br />
Captive<br />
lever<br />
Eyebolts<br />
‘O’ ring seal<br />
on face<br />
The Components<br />
The Isolating Closure consists of two principal pieces,<br />
isolating disc and backing plate. The preloading bolt<br />
(see Detail) is threaded into the backing plate. As the<br />
preloading bolt head is turned, it comes in contact with<br />
the face opposite the seat. From this point the top of<br />
the backing plate is forced away from the face opposite<br />
the seat, pivoting about the dome nut, until the bottom<br />
of the plate comes into contact with the face opposite<br />
the seat. Additional turning of the preloading bolt head<br />
results in the dome nut applying axial seating pressure<br />
to the isolating disc.<br />
Isolating Closure Installation<br />
The Isolating Closure is designed to be handled as one<br />
assembly. There are two eye bolts on the disc to assist in<br />
installation. The backing plate is held to the disc by two<br />
cap screws, but the backing plate is free to move axially.<br />
The Isolating Closure is lowered into the body, the<br />
preloading bolt tightened, which seats the “O” ring to<br />
the body. After the pressure seal assembly has been<br />
installed, the system is ready for hydrostatic testing. The<br />
testing pressure will cause the ring to seal even more<br />
tightly.<br />
Down stream leakage, past the “O” ring, should it occur<br />
can be determined by removing the pipe plug at the<br />
bottom of the body.<br />
After hydrostatic testing, the Isolating Closure is<br />
removed and the pressure seal assembly reinstalled.<br />
What the Dewrance Reheater Isolating<br />
Device Offers:<br />
To the Specifying Engineer, an Alternative!<br />
Whether for new construction or retrofit, there is now a<br />
workable choice other than blanking flanges for<br />
isolating a section of pipeline.<br />
To the Maintenance Engineer, Ease of Operation!<br />
One unit permits an efficient means of doing hydrostatic<br />
testing, wet or dry lay-up and chemical cleaning.<br />
To the Plant Chief Engineer, Savings Through Efficiency!<br />
Compared with the blanking flange method, the<br />
Isolating Closure is clearly better. Furthermore, it will pay<br />
for itself. Upon completion of the second operation the<br />
accumulated savings in reduced down-time and<br />
maintenance labour could cover the purchase cost.<br />
To the Plant Operations Manager, Increased Profitability!<br />
Consider the versatility, efficiency and savings of the<br />
Dewrance Reheater Isolating Device, then the impact on<br />
the “bottom line” is self evident.